| Manufacturer part number (MPN) | 7004-12881-0000000 |
| Model designation | MSC-U9 |
| EAN / GTIN | 4048879110945 |
| HS code | 8536.69 |
| EU customs tariff number | 85366990 |
| US customs tariff number | 8536694020 |
| Weight | 0.026 kg |
| Country of origin | HU |
| Sales unit | pcs |
| Side 1 - Family construction form | M12 |
| Side 1 - No. of poles | 5 |
| Side 1 - Coding | A |
| Side 1 - Gender | male |
| Side 1 - Mounting method | inserted, screwed |
| Side 1 - Threaded hole | M12 x 1 |
| Side 1 - Tightening torque | 0.6 Nm |
| Side 1 - Width across flats | SW18 |
| Side 1 - Cable outlet | angled |
| Side 1 - Degree of protection (EN IEC 60529) | IP67 |
| Side 2 - Mounting method | Field-wireable |
| Electrical data | Supply - Operating voltage DC max. | 60 V |
| Supply - Current operating per contact max. | 4 A |
| Supply - Current operating per contact max. (URc.) | 3 A |
| Diagnostics - Status indication LED | No |
| Installation - Rotation option | 90° (4 outlet directions) |
| Installation - Connection cross section max. | 0.75 mm² |
| Installation | Connection - Tightening torque | 0.6 Nm |
| Installation | Connection - Mounting set | M12 x 1 |
| Installation | Connection - Width across flats | SW18 |
| Electrical - Additional condition protection degree | inserted, screwed |
| Device protection | Electrical - Pollution Degree | 3 |
| Electrical - Overvoltage category (EN 60664-1) | III |
| Electrical - Overvoltage category (EN 60950-1) | II |
| Device protection | Electrical - Rated surge voltage | 0.8 kV |
| Electrical - Material group (IEC 60664-1) | III |
| Mechanical data | Material data - housing | PA |
| Mechanical data | Material data - Locking material | Stainless steel 1.4404 (V4A) |
| Mechanical data | Mounting data - Height | 41 mm |
| Mechanical data | Mounting data - Width | 40 mm |
| Mechanical data | Mounting data - Depth | 20 mm |
| Mechanical data | Mounting data - Mounting method | inserted, screwed, Shaking protection |
| Mechanical data | Mounting data - Clamping range min. | 6 mm |
| Mechanical data | Mounting data - Clamping range max. | 8 mm |
| Climatic - Operating temperature min. | -40 °C |
| Climatic - Operating temperature max. | 85 °C |
| Important installation notes - Note on bending radius | Attention: Observe the permissible bending radii when laying cables, as the IP protection class can be endangered by excessive bending forces. |
| Important installation notes - Note on strain relief | Protect the connectors by suitable measures from mechanical loads, e.g. by the usage of cable ties. |
| ETIM-5.0 | EC002635 |
| ETIM-6.0 | EC002635 |
| ETIM-7.0 | EC002635 |
| ETIM-8.0 | EC002635 |
| ETIM-9.0 | EC002635 |
| ETIM-10.0 | EC002635 |
| Packaging unit | 1 |
| ECLASS 14.0 | 27440106 |