Fixed-mount axial flow fan for engine-room, machinery-space and accommodation supply / extraction duty.
| Impeller | cast aluminium, anti-spark per ATEX EN 14986 |
| Casing | hot-dip galvanised steel tube-axial |
| Impeller diameter | 630 mm |
| Air flow | 9500 m³/h at free delivery |
| Motor | 4 kW, IE3, 440 V / 3-phase / 60 Hz (also 380 V / 50 Hz) |
| Speed | 1750 / 1450 rpm (60 / 50 Hz) |
| Protection | IP55 motor / drain plug fitted |
| Insulation class | H |
| Sound power | 78-92 dB(A) (size-dependent) |
| Temperature | -20 to +70 °C |
| Application | engine-room supply, ER extraction, purifier-room, pump-room (with Ex variant), cargo-pump-room (with Ex variant) |
| Material | Galvanised steel casing / cast aluminium impeller |
| MOQ | 1 ea |
Form-fit envelope of Sodeca THT, Novenco AZN/AZL, Witt & Sohn AXN, Flakt Woods JM Aerofoil and Heinen & Hopman EJM 630 mm tube-axial engine-room fans. Drop-in for any axial fan of the same impeller diameter and motor footprint.