readycable® hybrid cable suitable for SEW 2812 3743 with Movilink DDI, connection cable, PUR 10XD (MAT9851482)

igus · Safety & Detection · Tools · Germany · igus.com
Part Number
2812 3743  ·  HS 8544.42
readycable® hybrid cable suitable for SEW 2812 3743 with Movilink DDI, connection cable, PUR 10XD (MAT9851482)

readycable® motor cable suitable for SEW 2812 3743 with Movilink DDI, connection cable, PUR 10xd

Technical Specifications

Manufacturer part number (MPN)2812 3743
BrandIGUS
CategoryTools
Cable typeConnection cable
Connector AConnector M23 socket 9-pin
Connector Bval_307
Number of cores and conductor nominal cross-section(4G1.5+2x(2x1.0)C+HF50-0.9/2.95)C
Copper index kg/km191 kg/km
Core group 1 core structure4G1.5
Core group 2 core structure2x(2x1.0)C
Core group 3 core structureHF50-0.9/2.95
Shipping weight (kg or kg/m)0.118296
Outer diameter (d) max. mm15.5 mm
Weight per km304 kg/km
Min. bend radius, e-chain (factor)10 x d
Min. bend radius, e-chain155 mm
Min. bend radius, flexible (factor)8 x d
Min. bend radius, flexible124 mm
Min. bend radius, fixed (factor)5 x d
Min. bend radius, fixed77.5 mm
Temperature e-chain®-25°C up to +80°C
Temperature, flexible-40°C to +80°C (according to DIN EN 60811-504)
Temperature, fixed-50°C to +80°C (according to DIN EN 50305)
v max. unsupported (speed)10 m/s
v max. gliding (speed)2 m/s
a max. (acceleration)50 m/s²
travel lengthTravels up to 10 m
torsionNo Torsion
ConductorStranded conductor in a bend-resistant version consisting of bare copper wires (according to DIN EN 60228).
LinerFoil taping over the outer layer.
Overall shieldBend-resistant braiding made of tinned copper wires. Coverage approx. 55% linear, approx. 80% optical
Element shieldFlexible braiding made of tinned copper wires.
Outer jacketLow-adhesion, halogen-free, highly abrasion-resistant PUR mixture, adapted to suit the requirements in e-chains® (according to DIN EN 50363-10-2).
Outer jacket colourPastel orange (comparable to RAL 2003)
Nominal voltage600/1,000V (according to DIN VDE 0298-3)
Test voltage4000V (according to DIN EN 50395)
UV resistanceMedium
Oil resistanceOil-resistant (according to DIN EN 50363-10-2), Class 3
Silicone-freeFree from silicone which can affect paint adhesion (according to PV 3.10.7 – status 1992)
Halogen-freeAccording to DIN EN 60754
EACCertificate No. RU C-DE.ME77.B.00863/20
REACHIn accordance with Regulation (EC) No. 1907/2006 (REACH)
Lead-freeAccording to 2011/65/EU (RoHs-II/RoHS-III)
CleanroomAccording to ISO Class 1 The outer jacket material of this series complies with CF77.UL.05.12.D - tested by IPA according to standard DIN EN ISO 14644-1
CEAccording to 2014/35/EU
UL verifiedCertificate no
V293650"The igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year“
DESINAAccording to VDW, DESINA standardisation
Flame-retardantAccording to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame
NFPAAccording to NFPA 79-2018, chapter 12.9
OffshoreMUD-resistant according to NEK 606 - status 2018
UKCAIn accordance with the valid regulations of the United Kingdom (as of 08/2021)

Properties

MOQ1

Cross-References

Attached Documents