cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-08
sales@cballast.com
cballast.com

chainflex® motor cable CF885-PE, lead screw cable/single core (CF885.PE.25.01)

igus · Safety & Detection · Tools · Germany · igus.com
Part Number
CF885.PE.25.01  ·  HS 8544.49
chainflex® motor cable CF885-PE, lead screw cable/single core (CF885.PE.25.01)

chainflex® motor cable CF885-PE, lead screw cable/single core

Technical Specifications

Manufacturer part number (MPN)CF885.PE.25.01
BrandIGUS
CategoryTools
Number of cores and conductor nominal cross-section1G2.5
Protective conductorwith green-yellow earth core
Copper index kg/km25 kg/km
Shipping weight (kg or kg/m)0.059
Outer diameter (d) max. mm6.5 mm
Weight per km59 kg/km
Min. bend radius, e-chain (factor)15 x d
Min. bend radius, e-chain97.5 mm
Min. bend radius, flexible (factor)12 x d
Min. bend radius, flexible78 mm
Min. bend radius, fixed (factor)8 x d
Min. bend radius, fixed52 mm
Temperature e-chain®+5°C up to +70°C
Temperature, flexible-5°C to +70°C (according to DIN EN 60811-504)
Temperature, fixed-15°C to +70°C (according to DIN EN 50305)
v max. unsupported (speed)3 m/s
a max. (acceleration)20 m/s²
travel lengthUnsupported up to 10 m
torsionNo Torsion
ConductorConductor consisting of bare copper wires (according to DIN EN 60228).
Core insulationMechanically high-quality PVC mixture.
Outer jacketLow-adhesion PVC mixture, adapted to suit the requirements in e-chains®.
Outer jacket colourPastel orange (comparable to RAL 2003)
Nominal voltage600/1,000V (according to DIN VDE 0298-3)
Test voltage4000V (according to DIN EN 50395)
Oil resistanceNo oil resistance
Silicone-freeFree from silicone which can affect paint adhesion (according to PV 3.10.7 – status 1992)
EACCertificate No. RU C-DE.ME77.B.00302/19
REACHIn accordance with Regulation (EC) No. 1907/2006 (REACH)
Lead-freeAccording to 2011/65/EU (RoHs-II/RoHS-III)
CEAccording to 2014/35/EU
UL/CSA AWMStyle 10107, 600 V, 80 °C
UL verifiedCertificate no
V293650"The igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year“
Flame-retardantAccording to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2/Horizontal Flame
NFPAAccording to NFPA 79-2018, chapter 12.9

Properties

MOQ1