chainflex® control cable CF150.UL (CF150.UL.15.25)

igus · Safety & Detection · Tools · Germany · igus.com
Part Number
CF150-UL-15-25  ·  HS 8544.49
chainflex® control cable CF150.UL (CF150.UL.15.25)

chainflex® control cable CF150.UL

Technical Specifications

Manufacturer part number (MPN)CF150-UL-15-25
BrandIGUS
CategoryTools
Number of cores and conductor nominal cross-section25G1.5
Protective conductorwith green-yellow earth core
Copper index kg/km371 kg/km
Shipping weight (kg or kg/m)0.746
Outer diameter (d) max. mm24.5 mm
Weight per km746 kg/km
Min. bend radius, e-chain (factor)7.5 x d
Min. bend radius, e-chain183.75 mm
Min. bend radius, flexible (factor)6 x d
Min. bend radius, flexible147 mm
Min. bend radius, fixed (factor)4 x d
Min. bend radius, fixed98 mm
Temperature e-chain®+5°C up to +70°C
Temperature, flexible-5°C to +70°C (according to DIN EN 60811-504)
Temperature, fixed-15°C to +70°C (according to DIN EN 50305)
v max. unsupported (speed)3 m/s
v max. gliding (speed)2 m/s
a max. (acceleration)20 m/s²
travel lengthTravels up to 50 m
torsionTorsion ±90°, with 1m cable length, Class 2
ConductorFinely stranded conductor consisting of bare copper wires (according to DIN EN 60228).
Core insulationMechanically high-quality PVC/PA combination
Core strandingCores wound in bundles are then wound around a high tensile strength centre element, all with optimised short pitch lengths and directions. Especially low-torsion structure.
Outer jacketLow-adhesion, oil-resistant PVC mixture, adapted to suit the requirements in e-chains® (according to DIN EN 50363-4-1).
Outer jacket colourJet black (comparable to RAL 9005)
CFRIP®Strip cables faster: a tear strip is moulded into the outer jacket
Nominal voltageTC-ER 600V, WTTC 1,000V, MTW 600V
Test voltage2000V (according to DIN EN 50395)
UV resistanceMedium
Oil resistanceOil-resistant (according to DIN EN 50363-4-1), UL Oil Res I, Class 2
Silicone-freeFree from silicone which can affect paint adhesion (according to PV 3.10.7 – status 1992)
REACHIn accordance with Regulation (EC) No. 1907/2006 (REACH)
Lead-freeAccording to 2011/65/EU (RoHs-II/RoHS-III)
CEAccording to 2014/35/EU
UL verifiedCertificate no
V293650"The igus 4-year chainflex cable guarantee and service life calculator based on 2 billion test cycles per year“
UL-ListedTC-ER UL 1277, WTTC UL 2277, MTW UL 1063
Flame-retardantAccording to IEC 60332-1-2, Cable Flame, VW-1, FT1, FT2 / Horizontal Flame, FT4
NFPAAccording to NFPA 79-2018, chapter 12.9

Properties

MOQ1

Cross-References