| Manufacturer part number (MPN) | ICG653/U/EP-FM75NP |
| EAN / GTIN | 7071000092039 |
| Sales unit | pcs |
| Product type | Ex d / Ex e barrier cable gland |
| Series | Hawke ICG653/UNIV |
| Gland size | F |
| Entry thread | M75 |
| Cable inner sheath range | 59.0–66.2 mm |
| Cable outer sheath range | 57.0–78.0 mm |
| Material | Nickel-plated brass |
| Sealing | Epoxy potting compound |
| Hazardous area application | Hazardous Areas Zone 1, Zone 21, Zone 2, Zone 22 |
| Ingress protection | IP66, IP67, IP68 (30 metres for 7 days, special instruction apply); IP69 to IEC/EN 60529; NEMA 4X; Deluge Protection to DTS01 |
| Operating temperature | -60°C to +80 °C |
| Standards | IEC/EN 62444 (Anchorage Type D); IEC/EN 60079-0, 1, 7, 15, 31; CSA 60079-0, 1, 7, 31; CSA C22.2 No. 0-10, CSA C22.2 No. 174-18; UL2225; UL1203; UL 514B |
| Product family | Cable Glands for Group II Hazardous Areas |
| Ex marking | Ex II 2GD Ex db IIC Gb; Ex eb IIC Gb; Ex nR IIC Gc; Ex tb IIIC Db; Class I Div 1 ABCD; Class II Div 2 EFG and Class III; Class I, Zone I, AEx db IIC Gb; AEx eb IIC Gb; Zone 21, AEx tb IIIC Db |
| Impact rating | IK10 to IEC 62262 |
| ATEX certificate | CML 18ATEX1268X / CML 19ATEX4507 (Ex nR) |
| CCC certificate | 2020312313000317 |
| cCSAus certificate | 1024328 |
| DNV certificate | TAE0000BS |
| EAC certificate | KZ 7100841.01.01.03125 |
| EQM certificate | 20-11-27224/Q20-11-000979/NB0007 |
| IECEx certificate | CML 18.0131X / CML 21.0012X (Ex nR) |
| Inmetro certificate | IEx 14.0272X |
| KCs certificate | 17-KA4BO-0159X to 0167X |
| PESO certificate | P450038 |
| SONCAP certificate | LCOGB049552-0500 |
| UKEx certificate | CML 21UKEX1132X / CML 21UKEX4133X (Ex nR) |
| Thread type | Metric |
| Nominal thread size metric/PG | 75 |
| Pitch thread | 1.5 mm |
| Thread length | 15 mm |
| Wrench width | 95 mm |
| Hexagon angular dimension | 104 mm |
| Material quality | Brass |
| Surface protection | Nickel-plated |
| Halogen free | Yes |
| Glass-fibre reinforced | No |
| Shock resistant | Yes |
| Bend radius protection/trumpet flare | Yes |
| With locknut | No |
| Snapping in opening | Yes |
| Flat cable coupling | No |
| With strain relief | No |
| Type of sealing | Sealing ring |
| Separable screw gland | No |
| Explosion-tested version | Yes |
| For Ex-zone gas | 1, 2 |
| For Ex-zone dust | 21, 22 |
| For armoured cable | Yes |
| Country of origin | United Kingdom |