TU5200 Turbidimeter 360° X 90° with — Rfid, EPA Version

Hach · Chemical Test Kits · Water Analysis Meters · USA · hach.com
Part Number
LPV442.99.03012  ·  HS 9027.89
TU5200 Turbidimeter 360° X 90° with — Rfid, EPA Version

Hach TU5200 Turbidimeter 360° X 90° With — Rfid, EPA Version. Reference part number LPV442.99.03012.

Technical Specifications

Communication interfaceRFID
Accuracy±2% plus 0.01 NTU from 0 - 40 NTU; ±10% of reading from 40 - 1000 NTU based on Formazin primary standard (at 25 °C)
Calibration MethodFor Formazin and Stablcal; 20 NTU from 0 to 40 NTU; at 20 FNU and 600 NTU for full range; Custom calibration for up to 6-point calibrations; Degrees 0 - 100 mg/L; SDVB 0 - 1000 NTU
CertificationsCE compliant; US FDA accession number: 1420493-000 EPA version, 1420492-000 ISO version; Complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50); Australian ACMA Marking
CommunicationLink2sc and RFID
Dimensions (H x W x D)195 mm x 409 mm x 278 mm
Display7" WVGA (800 x 480) color TFT-LCD with touch screen
Enclosure ConstructionPC/ABS Blend Plastic
Light SourceClass 2 laser product, with embedded 650 nm (EPA 0.43 mW) or Class 1 laser product, with embedded 850 nm (ISO), max. 0.55 mW (complies with IEC/EN 60825-1 and to 21 CFR 1040.10 in accordance with Laser Notice No. 50)
ModelTU5200 EPA
Operating Humidity80% at 30 °C (non condensing)
Operating Temperature Range10 - 40 °C (50 - 104 °F)
Power Requirements (Hz)50/60 Hz
Power Requirements (Voltage)100 - 240 VAC
RangeEPA; 0 - 700 NTU / FNU / TE/F / FTU; 0 - 100 mg/L; 0 - 175 EBC; ISO; 0 - 1000 NTU / FNU / TE/F / FTU; 0 - 100 mg/L; 0 - 250 EBC
RegulatoryEPA
Repeatability<40 NTU: Better than 1% of reading or ±0.002 NTU on Formazin at 25 °C (77 °F), whichever is greater; >40 NTU: Better than 3.5% of reading on Formazin at 25 °C (77 °F)
Resolution0.0001 NTU / FNU / TE/F / FTU / EBC / mg/L
Response TimeSignal averaging off: 7 seconds; Signal averaging on: 10 seconds (when averaging time is 5 seconds)
Sample Temperature4 - 70°C (39 - 158°F)
Source LampEPA Version - 650 nm Class 2 Laser
Storage Conditions-30 to 60 °C (-22 to 140 °F)
Stray Light<10 mNTU
UnitsNTU, FNU, TE/F, FTU, EBC; mg/L if calibrated with Degrees calibration curve
Warranty12 months
Weight2.4 kg (5.29 lbs.)
What's includedTU5200 benchtop turbidimeter, user manual, Stablcal kit (10, 20 and 600 NTU), 2 sample vials, power supply, dust cover, vial stand