Generic FWG-TOL-16 FWG Vacuum-Ejector Water-Ring Pump Motor Thermal-Overload Relay 1.6-2.5 A (replacement) — service-interval spare for marine vacuum-distillation fresh-wate.
| Material | bimetal thermal-overload relay + Class 10A + 1NO + 1NC |
| Standards | IEC 60947-4-1 contactors and motor-starters — electromechanical, IEC 60947-5-1 control circuit devices and switching elements — electromechanical, IACS UR M77 ventilation of machinery spaces — drive systems, PED 2014/68/EU Article 4(3) SEP |
| Approvals | CE LVD 2014/35/EU + EMC 2014/30/EU, EN 10204 3.1 material certificate available, CE, EMC |
| HS code | 8419.90 |
| Setting range | 1.6-2.5 A |
| Material | bimetal thermal-overload relay + Class 10A + 1NO + 1NC |
| MOQ | 1 |
Form-fit envelope for Alfa Laval JWP, AQUA Blue, Sondex, GEA and Atlas Plant DPU fresh-water generator water-ring pump motor change-out, run-capacitor refresh and thermal-overload relay replacement workflow.