| Manufacturer part number (MPN) | 3448783 |
| Brand | Fluke |
| Category | Tools |
| Voltage DC Maximum voltage | 1000 V |
| Voltage DC Accuracy | ±(0.05% + 1) |
| Voltage DC Maximum resolution | 10 µV |
| Voltage AC Maximum voltage | 1000 V |
| Voltage AC Accuracy | ±(0.7% + 2) True RMS |
| Voltage AC AC bandwidth | 20 kHz with low pass filter; 3 dB @ 1 kHz |
| Voltage AC Maximum resolution | 0.1 mV |
| Current DC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current DC Amps accuracy | ±(0.2% + 2) |
| Current DC Maximum resolution | 0.01 µA |
| Current AC Maximum amps | 10 A (20 A for 30 seconds maximum) |
| Current AC Amps accuracy | ±(1.0% + 2) True RMS |
| Current AC Maximum resolution | 0.1 µA |
| Resistance Maximum resistance | 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Resistance Maximum resolution | 0.1 Ω |
| Capacitance Maximum capacitance | 9,999 µF |
| Capacitance accuracy | ±(1% + 2) |
| Capacitance Maximum resolution | 0.01 nF |
| Frequency Maximum frequency | 200 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Frequency Maximum resolution | 0.01 Hz |
| Duty cycle Maximum duty cycle | 99.9% |
| Duty cycle Accuracy | ±(0.2% per kHz + 0.1%) |
| Duty cycle Maximum resolution | 0.1% |
| Temperature measurement | –200.0 °C – 1090 °C –328.0 °F – 1994.0 °F excluding probe |
| 80 BK temperature probe | –40.0 °C – 260 °C –40.0 °F – 500 °F, 2.2 °C or 2% whichever is greater |
| Conductance Maximum conductance | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Conductance Maximum resolution | 0.01 nS |
| Diode Range | 3 V |
| Diode Resolution | 1 mV |
| Diode Accuracy | ±(2% + 1) |
| Duty cycle range Accuracy | Within ±(0.2% per kHz + 0.1%) |
| Operating temperature | –20 °C to + 55 °C |
| Storage temperature | –40 °C to + 60 °C |
| Humidity (without condensation) | 0% – 90% (0 °C – 35 °C) 0% – 70% (35 °C – 55 °C) |
| Operating Altitude | 2000 m |
| Overvoltage category | EN 61010–1 to 1000 V CAT III, 600V CAT IV |
| Agency approvals | CE, CSA, RCM |
| Size | 201 x 98 x 52 mm (with holster) |
| Weight | 355 g 624 g – with holster |
| Display Digital | 6000 counts updates 4/sec. 19,999 counts in high–resolution mode |
| Display Analog | 32 segments, updates 40/sec |
| Display Frequency | 19,999 counts, updates 3/sec at > 10 Hz |
| Warranty | Lifetime |
| Battery Life Alkaline | ~400 hours typical, without backlight |
| Shock | 1 Meter drop per IEC 61010–1:2001 |
| Vibration | Per MIL–PRF–28800 for a Class 2 instrument |
| Nominal current range | 400 A |
| Continuous current range | 1 A - 400 A |
| Maximum non-destructive current | 1000 A |
| Lowest measurable current | 1 A |
| Basic accuracy | 2% + 0.06 A |
| Useable frequency | 5 Hz - 20 kHz |
| Output level(s) | 1 mA/A |
| Safety | CAT IV 600 V, CAT III, 1000 V |
| Maximum voltage | 1000 V AC rms from earth to ground, in compliance with EN61010 |
| Maximum conductor diameter | 32 mm (1.25 in) |
| Maximum conductor size (busbar) | 750 MCM |
| Output cable length | 1.5 m (59 in) |
| Shrouded banana plugs | Yes |