Technical Specifications

Manufacturer part number (MPN)2452080 Brand: Fluke Category: Tools Voltage DC 30.000 V: 0.01% + 2 mV (upper display) Voltage DC 20.000 V: 0.01% + 2 mV (lower display) Voltage DC 90.00 mV: 0.01% + 10 μV Voltage DC -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector) Current DC 24.000 mA: 0.01%+ 2 mA Resistance 0.0 to 4000.0 Ω: ± 0.015% Frequency 2.0 to 1000.0 CPM: 0.05% + 0.1 cpm Frequency 1.0 to 1000.0 Hz: 0.05% + 0.1 Hz Frequency 1.00 to 15.00 kHz: 0.05% + 0.01 kHz Frequency Sensitivity: 1 V peak-to-peak-minimum Pressure: Accuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure
Voltage DC 100.00 mV0.01% + 10 μV Current DC 24.000 mA (Source): 0.01% + 2 μA Current DC 24.000 mA (Simulate): 0.01% + 2 μA Frequency 1.0 to 10.0 kHz: 0.25% Frequency 10.0 to 15.0 kHz: 0.5% Frequency Waveform: 5 V p-p squarewave, -0.1 V offset Measure and source accuracy Cu10: 1.8°C Measure and source accuracy NI-120: 0.15°C Measure and source accuracy PT-100 (385): 0.45°C Measure and source accuracy PT-100 (392): 0.35°C Measure and source accuracy PT-100 (391-JIS): 0.35°C Measure and source accuracy PT-200 (385): 0.95°C Measure and source accuracy PT-500 (385): 0.55°C Measure and source accuracy PT-1000 (385): 0.35°C Measure and source accuracy RTD Resolution: 0.01°C (0.01°F) Measure and source accuracy Cu10.01 C: 0.1°C (0.1°F) Measure and source accuracy J: 0.4°C Measure and source accuracy K: 0.5°C Measure and source accuracy T: 0.4°C Measure and source accuracy E: 0.4°C Measure and source accuracy R: 1.4°C Measure and source accuracy S: 1.4°C Measure and source accuracy B: 1.4°C Measure and source accuracy L: 0.45°C Measure and source accuracy U: 0.45°C Measure and source accuracy N: 0.6°C Measure and source accuracy XK: 0.4°C Measure and source accuracy BP: 1.1°C Measure and source accuracy TC Resolution: J, K, T, E, L, N, U: 0.1°C, 0.1°F B, R, S: 1°C, 1°F Ramp functions Source functions: Voltage, current, resistance, frequency, temperature Ramp functions Ramps: Slow ramp, Fast ramp, 25% step-ramp Loop power function Voltage: 24 V Loop power function Accuracy: 10% Loop power function Maximum current: 22 mA, short circuit protected Step functions Source functions: Voltage, current, resistance, frequency, temperature Step functions Steps: 25% of range, 100% of range Operating temperature: -10°C to +55°C Storage temperature: -20°C to +71°C Operating altitude: 3000 m Agency approvals: EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 Size: 200 x 96 x 47 mm (7.9 x 3.8 x 1.9 in) Weight: 650 g (23 oz) Batteries: 4 AA alkaline batteries Battery replacement: Separate battery compartment, accessible without breaking calibration seal Side port connections: Pressure module connector, also used for remote real-time programming

Properties

MOQ1

Cross-References

Attached Documents