Part Number
664133  ·  HS 9031.80
Fluke 725 Multifunction Process Calibrator

Fluke 725 Multifunction Process Calibrator calibrates almost anything & sources & measures almost all process parameters. Versatile, powerful. See specs.

Technical Specifications

Manufacturer part number (MPN)664133 Brand: Fluke Category: Tools Voltage DC 30.000 V: 0.02% + 2 counts (upper display) Voltage DC 100.00 mV: 0.02% + 2 counts Voltage DC -10.00 mV to 75.00 mV: 0.025% + 1 count (via TC connector) Current DC 24.000 mA: 0.02% + 2 counts Resistance 0.0 to 400.0 Ω: 0.1 Ω (4-wire), 0.15 Ω (2- and 3-wire) Resistance 401 to 1500 Ω: 0.5 Ω (4-wire), 1 Ω (2- and 3-wire) Resistance 1500 to 3200 Ω: 1 Ω (4-wire), 1.5 Ω (2- and 3-wire) Frequency 2.0 to 1000.0 CPM: 0.05% + 1 count Frequency 1.0 to 1100.0 Hz: 0.05% + 1 count Frequency 1.00 to 10.00 kHz: 0.05% + 1 count Frequency Sensitivity: 1 V peak-to-peak-minimum Pressure: Accuracy from 0.025% of range using any of (50) 750P pressure modules (for detailed specifications refer to pressure modules in options and accessories). Modules available for differential, gauge, vacuum, absolute, dual and high pressure
Voltage DC 10.000 V0.02% + 2 counts Current DC 24.000 mA (source): 0.02% + 2 counts Current DC 24.000 mA (simulate): 0.02% + 2 counts Resistance 15.0 to 400.0 Ω: 0.15 Ω (exc. current 0.15 to 0.5 mA), 0.1 Ω (exc. current 0.5 to 2 mA) Frequency Waveform: 5 V p-p squarewave, -0.1 V offset Measure accuracy NI-120: 0.2°C Measure accuracy PT-100 (385): 0.33°C Measure accuracy PT-100 (393): 0.3°C Measure accuracy PT-100 (JIS): 0.3°C Measure accuracy PT-200 (385): 0.2°C Measure accuracy PT-500 (385): 0.3°C Measure accuracy PT-1000 (385): 0.2°C Measure accuracy Resolution: 0.1°C Measure accuracy J: 0.7°C Measure accuracy K: 0.8°C Measure accuracy T: 0.8°C Measure accuracy E: 0.7°C Measure accuracy R: 1.8°C Measure accuracy S: 1.5°C Measure accuracy B: 1.4°C Measure accuracy L: 0.7°C Measure accuracy U: 0.75°C Measure accuracy N: 0.9°C Measure accuracy XK: 0.6°C Measure accuracy BP: 1.2°C Source accuracy NI-120: 0.2°C Source accuracy PT-100 (385): 0.33°C Source accuracy PT-100 (393): 0.3°C Source accuracy PT-100 (JIS): 0.3°C Source accuracy PT-200 (385): 0.2°C Source accuracy PT-500 (385): 0.3°C Source accuracy PT-1000 (385): 0.2°C Source accuracy Resolution: 0.1°C Resolution: J, K, T, E, L, N, U: 0.1°C, B, R, S: 1°C XK: 0.6°C BP: 1.2°C Ramp functions Source functions: Voltage, current, resistance, frequency, temperature Ramp functions Ramps: Slow ramp, Fast ramp, 25% step-ramp Loop power function Voltage: 24 V Loop power function Accuracy: 10% Loop power function Maximum current: 22 mA, short circuit protected Step functions Source functions: Voltage, current, resistance, frequency, temperature Step functions Steps: 25% of range, 100% of range Operating temperature: -10°C to +55°C Storage temperature: -20°C to 71°C Operating altitude: 3000 m Agency approvals: EN 61010-1:1993, ANSI/ISA S82.01-1994; CAN/CSA C22.2 No 1010.1:1992 Size: 130 x 236 x 61 mm Weight: 0.65 kg Batteries: 4 AA alkaline batteries Battery replacement: Separate battery compartment, accessable without breaking calibration seal Side port connections: Pressure module connector, also used for remote real-time programming

Properties

MOQ1

Cross-References

Attached Documents