| Manufacturer part number (MPN) | 2840265 |
| Brand | Fluke |
| Category | Tools |
| Current measurement AC 10 Hz to 100 Hz Range | 40 A / 400 A / 1400 AC rms |
| Current measurement AC 10 Hz to 100 Hz Resolution | 10 mA / 100 mA / 1 A |
| Current measurement AC 10 Hz to 100 Hz Accuracy | 40 A: 1.5% rdg + 15 digits 400 A: 1.5% rdg + 5 digits 1400 A: 1.5% rdg + 5 digits |
| Trigger level for Inrush | 0.50 A / 5.0 A / 5 A |
| Trigger level for Hz filter OFF | 2.50 A / 2.5 A / 8 A |
| Trigger level for Hz filter ON | 0.50 A / 2.5 A / 8 A |
| Crest Factor (50/60 Hz) Range | 40 A / 400 A / 1400 AC |
| Crest Factor (50/60 Hz) Crest Factor1 | 2 @ 33 A, 2.4 @ 27 A 2 @ 330 A, 2.4 @ 270 A 2 @ 1000 A, 2.4 @ 833 A |
| Current measurement AC 100.1 Hz to 1 kHz Range | 40 A / 400 A / 1400 AC rms |
| Current measurement AC 100.1 Hz to 1 kHz Resolution | 10 mA / 100 mA / 1 A |
| Current measurement AC 100.1 Hz to 1 kHz Accuracy | 40 A: 3.5% rdg + 15 digits 400 A: 3.5% rdg + 5 digits 1400 A: 3.5% rdg + 5 digits |
| Current measurement DC Range | 40 A / 400 A / 2000 A |
| Current measurement DC Resolution | 0.01 A / 0.1 A / 1 A |
| Current measurement DC Accuracy | 40 A: 1.5% rdg + 15 digits 400 A: 1.5% rdg + 5 digits 2000 A: 1.5% rdg + 5 digits |
| Range | 4 V / 40 V / 400 V / 600 V AC rms |
| Resolution | 1 mV / 10 mV / 100 mV / 1 V |
| Accuracy | 4 V: 1% rdg + 10 digits 40 V: 1% rdg + 5 digits 400 V: 1% rdg + 5 digits 600 V: 1% rdg + 5 digits |
| Voltage measurement DC Range | 4 V / 40 V / 400 V / 1000 V |
| Voltage measurement DC Resolution | 0.001 V / 0.01 V / 0.1 V / 1 V |
| Voltage measurement DC Accuracy | 4 V: 1% rdg + 10 digits 40 V: 1% rdg + 5 digits 400 V: 1% rdg + 5 digits 1000 V: 1% rdg + 5 digits |
| Resistance measurement Range | 400 Ω / 4 kΩ / 40 kΩ / 400 kΩ |
| Resistance measurement Resolution | 0.1 Ω / 1 Ω / 10 Ω / 100 Ω |
| Resistance measurement Accuracy | 1.5% + 5 digits |
| Continuity beeper | On at ≤ 30 Ω Off at ≥ 100 Ω |
| Frequency measurement Measurement range | 5.0 Hz to 1 kHz |
| Frequency measurement Resolution | 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz) |
| Frequency measurement Accuracy – 5.0 Hz to 100 Hz | 0.2% + 2 counts |
| Frequency measurement Accuracy – 100.1 Hz to 1 kHz | 0.5% + 5 counts |
| Frequency measurement Trigger level | Refer to current and voltage tables |
| Batteries | Six 1.5 V AA NEDA 15 A or IEC LR6 |
| Battery life (with typical usage, backlight off) | 100 hours |
| Test leads | Rated to 1000 V |
| Weight | .814 kg (1.8 lb) |
| Jaw size | 58 mm (2.28 in) |
| Dimensions (L x W x D) | 300 x 98 x 52 mm (12 x 3.75 x 2 in) |
| Safety rating | IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III |
| Operating temperature | 32°F to +122°F (0°C to +50°C) |
| Storage temperature | -4°F to 140°F (-20°C to +60°C) |
| Operating humidity | 0 to 95% (non-condensing) |
| Operating altitude | 2000 m |
| Storage altitude | 10,000 m |
| IP rating | 42 (indoor use only) |
| Drop test requirements | 1 m |
| EMI, RFI |
| EMC | FCC part 15, IEC/EN 61326-1:1997 class B IEC/EN 61326:1997 3 V/m, performance criteria B, EN61325 |
| Temperature coefficients Current | 0.1% of reading per °C outside 22°C to 24°C |
| Temperature coefficients Voltage | 0.1% of reading per °C outside 22°C to 24°C |