| Manufacturer part number (MPN) | 4465599 Brand: Fluke Category: Tools Range ¹ / Resolution: 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V Accuracy 2 3 4 45 Hz to 500 Hz: 1.0% + 3 Accuracy 2 3 4 500 Hz to 1 kHz: 2.0% + 3 mV Range / Resolution: 600.0 mV / 0.1 mV mV Accuracy: 0.09% + 2 V Range / Resolution: 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V V Accuracy: 0.09% + 2 0.15% + 2 ))) Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer |
| Diode test Range / Resolution | 2.000 V / 0.001 V Diode test Accuracy: 1% + 2 µF Range / Resolution: 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF µF Accuracy: 1.2% + 2 10% typical mA AC (45 Hz to 1 kHz) Range 1 / Resolution: 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3 mA DC 2 Range 1 / Resolution: 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA mA DC 2 Accuracy: 0.5% + 3 Accuracy 1: 0.1% + 1 Function Overload protection: Input impedance (nominal) 1100 Vrms: > 10 MΩ < 100 pF Open circuit test voltage Full scale voltage: Typical short circuit current To 6 MΩ 50 MΩ: Typical short circuit current Overload protection: Fused, 44/100 A, 1000 V FAST Fuse Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration |
| AC functions | The specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration. Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec Display (LCD) Volts, amps, ohms: 6000 counts Display (LCD) Frequency: 10,000 counts Display (LCD) Capacitance: 1,000 counts Battery type: Three AA Alkaline batteries |
| NEDA 15A IEC LR6 Battery life | 250 hours minimum RF communications: 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m RF communication range Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m Temperature Operating: -10°C to 50°C Temperature Storage: -40°C to 60°C Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C) Relative humidity: 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m Altitude Storage: 12,000 m Electromagnetic compatibility EMI, RFI, EMC |
| RF | EN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE Safety compliance: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 Certifications: CSA, FCC |
| CE Ingress Protection (IP) rating | IP54 Pollution Degree: 2 Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight: 340 g (12 oz) Warranty: Three years Range: 0.5 A to 2500 A AC Resolution: 0.1 A Crest factor (50 Hz/60 Hz): 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A add 2% for C.F. > 2 LCD w/ backlight: 3½ digits Log rate/interval: 1 sec minimum/adjustable by PC or front panel Memory: Record up to 65,000 readings Operating temperature: -10°C to +50°C Storage temperature: -40°C to +60°C Operating humidity: 90% at 35°C 75% at 40°C 45% at 50°C EMC: EN 61326-1:2006 Safety rating: CAT IV 600 V |
| CAT III 1000 V Jaw opening | 25.4 cm (10 in) coil Size (H x W x D): 16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition Safety compliance CAN/CSA-C22.2 No 61010-1-12: 3rd edition Safety compliance UL 61010-1: 3rd edition Safety compliance IEC/EN 61010-1: 2010 |