cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Fluke 3000 FC General Maintenance System

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
4467750
Fluke 3000 FC General Maintenance System

Fluke 3000 FC General Maintenance System lets you work on electrical panels faster, safer, easier. Connect the remote modules, view readings from a distance.

Technical Specifications

Manufacturer part number (MPN)4467750 Brand: Fluke Category: Tools Range ¹ / Resolution: 600.0 mV / 0.1 mV 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V Accuracy 2 3 4 45 Hz to 500 Hz: 1.0% + 3 Accuracy 2 3 4 500 Hz to 1 kHz: 2.0% + 3 mV Range / Resolution: 600.0 mV / 0.1 mV mV Accuracy: 0.09% + 2 V Range / Resolution: 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V 1000 V / 1 V V Accuracy: 0.09% + 2 0.15% + 2 ))) Accuracy: Meter beeps at < 25 Ω, beeper detects opens or shorts of 250 μs or longer
Diode test Range / Resolution2.000 V / 0.001 V Diode test Accuracy: 1% + 2 µF Range / Resolution: 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF1 / 1 μF µF Accuracy: 1.2% + 2 10% typical mA AC (45 Hz to 1 kHz) Range 1 / Resolution: 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA mA AC (45 Hz to 1 kHz) Accuracy: 1.5% + 3 mA DC 2 Range 1 / Resolution: 60.00 mA / 0.01 mA 400.0 mA 3/ 0.1 mA mA DC 2 Accuracy: 0.5% + 3 Accuracy 1: 0.1% + 1 Function Overload protection: Input impedance (nominal) 1100 Vrms: > 10 MΩ < 100 pF Open circuit test voltage Full scale voltage: Typical short circuit current To 6 MΩ 50 MΩ: Typical short circuit current Overload protection: Fused, 44/100 A, 1000 V FAST Fuse Overload: 600 mA overload for 2 minutes maximum, 10 minutes rest minimum DC functions: The specified accuracy of the measurement function ±12 counts for changes > 350 mS in duration
AC functionsThe specified accuracy of the measurement function ±40 counts for changes > 900 mS in duration. Maximum voltage between any terminal and earth ground: 1000 VDC or AC rms Ω fuse protection from A inputs: 0.44 A (44/100 A, 440 mA), 1000 V FAST Fuse, Fluke specified part only Display (LCD) Update rate: 4/sec Display (LCD) Volts, amps, ohms: 6000 counts Display (LCD) Frequency: 10,000 counts Display (LCD) Capacitance: 1,000 counts Battery type: Three AA Alkaline batteries
NEDA 15A IEC LR6 Battery life250 hours minimum RF communications: 2.4 GHZ ISM Band RF communication range Open air, unobstructed: Up to 20 m RF communication range Obstructed, sheetrock wall: Up to 6.5 m Obstructed, concrete wall, or steel electrical enclosure: Up to 3.5 m Temperature Operating: -10°C to 50°C Temperature Storage: -40°C to 60°C Temperature coefficient: 0.1 x (specified accuracy) / °C ( 28°C) Relative humidity: 0% to 90% (0°C to 35°C) 0% to 75% (35°C to 40°C) 0% to 45% (40°C to 50°C) Altitude Operating: 2,000 m Altitude Storage: 12,000 m Electromagnetic compatibility EMI, RFI, EMC
RFEN 61326-1:2006, EN 61326-2-2:2006 ETSI EN 300 328 V1.7.1:2006, ETSI EN 300 489 V1.8.1:2008, FCC Part 15 Subpart C Sections 15.207, 15.209, 15.249 FCCID : FCC: T68-FDMMBLE IC: 6627A-FDMMBLE Safety compliance: ANSI/ISA 61010-1 / (82.02.01): 3rd edition CAN/CSA-C22.2 No 61010-1-12: 3rd edition UL 61010-1: 3rd edition IEC/EN 61010-1:2010 Certifications: CSA, FCC
CE Ingress Protection (IP) ratingIP54 Pollution Degree: 2 Size (H x W x L): 4.75 x 9.3 x 20.7 cm (1.87 x 3.68 x 8.14 in) Weight: 340 g (12 oz) Warranty: Three years LCD w/ backlight: 3½ digits, 6000 counts, updates 4/sec Memory: Record up to 65000 readings Operating temperature: -10°C to +50°C Storage temperature: -40°C to +60°C Operating humidity: 90% at 35°C, 45% at 40°C, 45% at 50°C EMC: EN 61326-1:2006 Safety compliance ANSI/ISA 61010-1 / (82.02.01): 3rd edition Safety compliance CAN/CSA-C22.2 No 61010-1-12: 3rd edition Safety compliance UL 61010-1: 3rd edition Safety compliance IEC/EN 61010-1: 2010 Safety rating: CAT IV 600 V
CAT III 1000 V Size (H x W x D)16.5 x 6.35 x 1.4 cm (6.5 x 2.5 x 1.4 in) mVDC Range ¹ / Resolution: 600.0 mV / 0.1 mV mVDC Accuracy: 0.09% + 3 VDC Range ¹ / Resolution: 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V VDC Accuracy: 0.09% + 3 Log rate/interval: Adjustable by PC from 1 sec to 1 hr, default 1 min Range: 0.5 A to 2500 A AC Resolution: 0.1 A Crest factor (50 Hz / 60 Hz): 3.0 at 1100 A 2.5 at 1400 A 1.42 at 2500 A add 2% for C.F. > 2 Jaw opening: 25.4 cm (10 in) coil

Properties

MOQ1

Cross-References

Attached Documents