| Manufacturer part number (MPN) | 4017176 |
| Brand | Fluke |
| Category | Tools |
| DC voltage Range | 0.1 mV to 1000 V |
| DC voltage Accuracy | ±(0.05% + 1) |
| AC voltage Range | 0.1 mV to 1000 V |
| AC voltage Accuracy | ±(0.7% + 4) |
| DC current Range | 0.1 μA to 10 A |
| DC current Accuracy | ±(0.2% + 4) |
| AC current Range | 0.1 μA to 10 A |
| AC current Accuracy | ±(1% + 2) |
| Resistance Range | 0.1 Ω to 50 MΩ |
| Resistance Accuracy | ±(0.2% + 1) |
| Conductance Range | 60.00 nS |
| Conductance Accuracy | ±(1.0% + 10) |
| Diode test Range | 2.0 V |
| Diode test Accuracy | ±(2.0% + 1) |
| Duty cycle Range | 0.0% to 99.9% |
| Duty cycle Accuracy | Within ±(0.2% per kHz + 0.1%) for rise times <1 µs |
| Capacitance Range | 10 nF to 9999 μF |
| Capacitance Accuracy | ±(1% + 2) |
| Frequency Range | 0.5 Hz to 199.99 kHz |
| Frequency Accuracy | ±(0.005% + 1) |
| Temperature Range | -200°C to +1090°C (-328°F to +1994°F) |
| Temperature Accuracy | ±(1% + 10)°C [±(1% + 10)°F] |
| Display counts | 6000 counts/19,999 counts in high-resolution mode |
| Peak capture | Record transients up to 250 us |
| Min/Max/Avg recording | Display signals up to approximately 100 ms |
| ATEX | {Ex} II 2G Ex ia IIC T4 Gb |
| NEC-500 | Class I, Div 1, Groups A-D, 130°C |
| IECEx | Ex ia IIC T4 Gb |
| GOST R Ex | 1Ex ia IIC T4 Gb X |
| Display | LCD, with backlight |
| External protection | Rubber holster |
| Warranty | Three years |
| Size with holster (H x W x L) | 6.4 x 10.0 x 19.8 cm (2.5 x 3.9 x 7.8 in) |
| Weight with holster | 700 g (1.54 lb) |