Fluke 190 Series III ScopeMeter® Test Tools

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
5282331  ·  HS 9030.20
Fluke 190 Series III ScopeMeter® Test Tools

Get the Fluke 190 Series handheld portable oscilloscope. Install, commission, and maintain industrial machinery, automation and process controls, and power conversion electronics.

Technical Specifications

Manufacturer part number (MPN)5282331 Brand: Fluke Category: Tools Bandwidth 60 MHz: 100 MHz Rise time 5.8 ns: 3.5 ns 2 input channels plus external trigger: 4 input channels Channel architecture: All inputs fully insulated from each other and from ground. Inputs may be activated in any combination
Input couplingAC or DC, with ground level indicator Input sensitivity: With 10:1 probe, 20 mV to 1000 V/div With 100:1 probe, 200 mV to 10 kV/div Direct (1:1), 2 mV to 100 V/div Bandwidth limiter: 20 MHz and 10 kHz Polarity: Normal, Inverted
Variable Input voltageCAT III 1000 V/CAT IV 600 V rated, see General specifications for further details Vertical resolution: 8 bit Accuracy at 4 s to 10 μs/div: 5 mV/div to 100 V/div, ±(1.5 % + 6 counts) 2 mV/div, ±(1.5 % + 10 counts) Input impedance: 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) 625 MS/s (each channel): 1.25 GS/s (each channel) Record length: Up to 10,000 samples per channel Time base range 10 ns/div to 4 s/div: 5 ns/div to 4 s/div Maximum record length: 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’) Timing accuracy: ± (0.01 % of reading + 1 pixel) Glitch capture: 8 ns (10 µs/div to 2 min/div) Display: 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD Display modes: Any combination of channels; average on/off; replay
Visible screen width12 divisions horizontally in scope mode digital persistence modes: Off, short, medium, long, infinite and envelope mode Waveform mathematics: One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B
C and D)add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT Acquisition modes: Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay Modes: Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2) Connect-and- View™: Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred. Pulse width triggering (on channel A): Pulse width qualified by time Allows for triggeringt, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns Time delay: 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay Dual slope triggering: Triggers on both rising and falling edges alike N-cycle triggering: Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99 Replay: Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp
Replay storageTen sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port
WindowAutomatic, Hamming
Hanning or None Automatic windowDigitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant
Vertical scaleLinear/Logarithmic (in volts or amps) Waveform compare: Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope
Pass/Fail testingIn waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis. Advanced power and motor drive functions: V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters Source: On any input waveform or on mathematical resultant waveform (excl
X-Y-mode) Dual horizontal linesVoltage at cursor 1 and at cursor 2, voltage between cursors Dual vertical lines: Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors
Single vertical lineMin-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant Advanced functions: mA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors) ZOOM: Ranges from full record overview to zoom in up to sample level, at any record length. Number of readings One at a time via DMM input: Up to 4 automatic scope measurements simultaneously Maximum resolution 5,000 counts: ± 999 counts (frequency: 9999 counts) Input impedance 1 MΩ (± 1 %) // 14 pF (± 1.5 pF): 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) Advanced meter functions: Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording V dc accuracy ± (0.5 % + 6 counts): ± (1.5 % + 6 counts) 15 Hz to 60 Hz ± (1 % + 10 counts): ± (1.5 % + 10 counts) 60 Hz to 20 kHz —: ± (2.5 % + 15 counts) Current (A): A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A Temperature: With optional accessories. Scale factors 1mV/°C or 1mV/°F Input A, Input B, Dual All channels sampled simultaneously: Any combination of inputs, up to 4 channels. All channels sampled simultaneously Source and display Memory depth: 30,000 data points per channel, each holding min/max pair of information Stop-on-trigger: ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series) Horizontal scale: Time from start, time of day Memory: Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis
Time base range4 ms/div to 2 min/div Recorded timespan: 4.8 sec to 40 hr Time/division in ‘view all’ mode: 0.4 s/div to 4 h/div Sample rate: 125 MS/s Resolution: 160 μsec ~ 4.8 sec Source and display: Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments) Memory depth: 19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp
RangesNormal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record) Recording mode: Continuous recording, starting at 5 s/div with automatic time-scale compression Measurement speed: Three automatic measurements per second or more Rated maximum floating voltage: CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level) Probe input voltage VPS410-II: CAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead) Probe input voltage VPS421: CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead) Maximum BNC input voltage: CAT IV 300 V (maximum voltage on BNC input directly) Memory loca- tions (internal): 30 waveform memories plus 10 recording memories plus 9 screen copy memories 30 waveform memories: Each memory can contain up to 2 or 4 waveforms plus corresponding setups. 10 recording memories: Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements External data storage: On PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port Screencopies: On PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port Volatility: Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status
Real-time clockProvides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings
DesignRugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard. Kensington lock supported to lock down instrument when left unattended
Drip and dust proofIP 51 according to IEC60529 Shock and vibration: Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2 Display size: 133 mm x 90 mm (5.3 in x 3.5 in) LCD Brightness: User-adjustable, up to 300 cd/m2 Size: 265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in) Weight (including battery) 2.1 kg (4.6 lb): 2.2 kg (4.8 lb) Line power: Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz Battery power: Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument 2½ hours using BP290; 5 hours using BP291: Five hours for BP291 Battery power saving functions: Auto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time. On-screen battery power indicator Compliance: EN61010-1, Pollution Degree 2; IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V Operating temperature: Battery discharging: 0 °C to 40 °C (32 °F to 104 °F) Battery charging: 0 °C to 40 °C (32 °F to 104 °F) Storage temperature: -20 °C to 60 °C (-4 °F to 140 °F) Humidity: 0 °C to 10 °C (32 °F to 50 °F): noncondensing 10 °C to 30 °C (50 °F to 86 °F): 95 % (±5 %) 30 °C to 40 °C (86 °F to 104 °F): 75 % (±5 %) 40 °C to 50 °C (104 °F to 122 °F): 45 % (±5 %) Maximum operating altitude: CAT IV 600 V
CAT III 1000 Vup to 2000 m (6 600 feet) CAT IV 300 V, CAT III 600 V
CAT II 1000 Vup to 4000 m (13 000 feet) Maximum storage altitude: 12 km (40,000 ft) Electro-Magnetic Compatibility (EMC): IEC 61326-1: Industrial; CISPR 11: Group 1, Class A; Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment); USA (FCC): 47 CFR 15 subpart C
Probe calibration outputDedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel
Generator Output1.225 Vpp / 500 Hz square wave Warranty: 3 years on main instrument, 1 year on battery and accessories Battery charger/ mains adapter: BC190/830 Li-Ion battery pack BP290 (10.8V, 2500 mAh): BP291 (10.8V, 5000 mAh) Optional configuration: Each model is available as a ‘boxed’ version, described above, or with the optional SCC293 set included
SCC293 comprisesCXT293 rugged protective carrying case, full-version FlukeView PC software (activation code) and a WiFi dongle for wireless PC-connectivity using FlukeView-2 software
Optional accessoriesSCC293, VPS101 - 1:1 voltage probe; VPS510-x - wide bandwidth compact probes; i400s–current clamp; HH290–hanging hook; CXT293–protective carrying case; TRM50–BNC Feedthrough cable terminator, 50 Ω, safety designed; EBC290–battery charging bay