cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Fluke 117 Electrician's Multimeter with Non-Contact Voltage

Fluke · Safety & Detection · Tools · USA · fluke.com
Part Number
2538815  ·  HS 9030.33
Fluke 117 Electrician's Multimeter with Non-Contact Voltage

Check out the Fluke 117 digital multimeter for efficiency in low light. The ideal multimeter to prevent false readings caused by ghost voltage. Buy Now!

Technical Specifications

Manufacturer part number (MPN)2538815
BrandFluke
CategoryTools
Fluke 117 Electrician's MultimeterFluke 115 Field Technicians Digital Multimeter
Maximum voltage between any terminal and earth ground600 V
SafetyIEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V
Fuse for A input11 A, 1000 V FAST Fuse (Fluke PN 803293)
DisplayDigital: 6,000 counts, updates 4 per second
Bar graph33 segments, updates 32 per second
Operating temperature-10°C to +50°C
Storage temperature-40°C to +60°C
Battery type9 volt Alkaline, IEC 6LR61
Battery life400 hours typical, without backlight
DC millivolts Range/resolution600.0 mV / 0.1 mV
DC millivolts Accuracy±([% of reading] + [counts]): 0.5% + 2
DC volts Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
DC volts Accuracy±([% of reading] + [counts]): 0.5% + 2
Auto volts Range/resolution600.0 V / 0.1 V
Auto volts Accuracy2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz)
AC millivolts¹ True RMS Range/resolution600.0 mV / 0.1 mV
AC millivolts¹ True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
AC volts¹ True RMS Range/resolution6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V
AC volts¹ True RMS Accuracy1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz)
Continuity Range/resolution600 Ω / 1 Ω
Continuity AccuracyBeeper on 250 Ω detects opens or shorts of 500 μs or longer.
Ohms Range/resolution600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ
Ohms Accuracy0.9% + 1
Diode test Range/resolution2.00 V / 0.001 V
Diode test Accuracy0.9% + 2
Capacitance Range/resolution1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF
Capacitance Accuracy1.9% + 2
Lo-Z capacitance Range1 nF to 500 μF
Lo-Z capacitance Accuracy10% + 2 typical
AC amps True RMS (45 Hz to 500 Hz) Range/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
AC amps True RMS (45 Hz to 500 Hz) Accuracy1.5% + 3 20 A continuous overload for 30 seconds max
DC amps Range/resolution6.000 A / 0.001 A 10.00 A / 0.01 A
DC amps Accuracy1.0% + 3 20 A continuous overload for 30 seconds max
Hz (V or A input)² Range/resolution99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz
Hz (V or A input)² Accuracy0.1% + 2
Size167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in)
Weight550 g
Warranty3 years

Properties

MOQ1

Cross-References