| Manufacturer part number (MPN) | 2538815 |
| Brand | Fluke |
| Category | Tools |
| Fluke 117 Electrician's Multimeter | Fluke 115 Field Technicians Digital Multimeter |
| Maximum voltage between any terminal and earth ground | 600 V |
| Safety | IEC 61010-1: Pollution Degree 2 IEC 61010-2-033: CAT III 600V |
| Fuse for A input | 11 A, 1000 V FAST Fuse (Fluke PN 803293) |
| Display | Digital: 6,000 counts, updates 4 per second |
| Bar graph | 33 segments, updates 32 per second |
| Operating temperature | -10°C to +50°C |
| Storage temperature | -40°C to +60°C |
| Battery type | 9 volt Alkaline, IEC 6LR61 |
| Battery life | 400 hours typical, without backlight |
| DC millivolts Range/resolution | 600.0 mV / 0.1 mV |
| DC millivolts Accuracy | ±([% of reading] + [counts]): 0.5% + 2 |
| DC volts Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| DC volts Accuracy | ±([% of reading] + [counts]): 0.5% + 2 |
| Auto volts Range/resolution | 600.0 V / 0.1 V |
| Auto volts Accuracy | 2.0% + 3 (DC, 45 Hz to 500 Hz) 4.0% + 3 (500 Hz to 1 kHz) |
| AC millivolts¹ True RMS Range/resolution | 600.0 mV / 0.1 mV |
| AC millivolts¹ True RMS Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
| AC volts¹ True RMS Range/resolution | 6.000 V / 0.001 V 60.00 V / 0.01 V 600.0 V / 0.1 V |
| AC volts¹ True RMS Accuracy | 1.0% + 3 (DC, 45 Hz to 500 Hz) 2.0% + 3 (500 Hz to 1 kHz) |
| Continuity Range/resolution | 600 Ω / 1 Ω |
| Continuity Accuracy | Beeper on 250 Ω detects opens or shorts of 500 μs or longer. |
| Ohms Range/resolution | 600.0 Ω / 0.1 Ω 6.000 kΩ / 0.001 kΩ 60.00 kΩ / 0.01 kΩ 600.0 kΩ / 0.1 kΩ 6.000 MΩ / 0.001 MΩ |
| Ohms Accuracy | 0.9% + 1 |
| Diode test Range/resolution | 2.00 V / 0.001 V |
| Diode test Accuracy | 0.9% + 2 |
| Capacitance Range/resolution | 1000 nF / 1 nF 10.00 μF / 0.01 μF 100.0 μF / 0.1 μF 9999 μF / 1 μF 100 μF to 1000 μF |
| Capacitance Accuracy | 1.9% + 2 |
| Lo-Z capacitance Range | 1 nF to 500 μF |
| Lo-Z capacitance Accuracy | 10% + 2 typical |
| AC amps True RMS (45 Hz to 500 Hz) Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| AC amps True RMS (45 Hz to 500 Hz) Accuracy | 1.5% + 3 20 A continuous overload for 30 seconds max |
| DC amps Range/resolution | 6.000 A / 0.001 A 10.00 A / 0.01 A |
| DC amps Accuracy | 1.0% + 3 20 A continuous overload for 30 seconds max |
| Hz (V or A input)² Range/resolution | 99.99 Hz / 0.01 Hz 999.9 Hz / 0.1 Hz 9.999 kHz / 0.001 Hz 50.00 kHz / 0.01 Hz |
| Hz (V or A input)² Accuracy | 0.1% + 2 |
| Size | 167 x 84 x 46 mm (6.57 x 3.31 x 1.82 in) |
| Weight | 550 g |
| Warranty | 3 years |