| Manufacturer part number (MPN) | 5009268 |
| Brand | Fluke |
| Category | Tools |
| Range Sensitivity range | ±32 g |
| Range Frequency range | 10 Hz to 1000 Hz |
| Range Sampling rate | 25600 Hz |
| Temperature Operating range | -30 °C to +80 °C (-20 °F to +176 °F) |
| Temperature Storage range | -30 °C to +80 °C (-20 °F to +176 °F) |
| Temperature Trending range | Displays temperature trends between -30 °C and +80 °C (-20 °F and +176 °F) |
| Relative humidity | 10 % to 95 % non-condensing |
| Altitude Operating | 2000 m |
| Altitude Storage | 12000 m |
| Size (H x W) | 2.42 x 0.95 in (61.5 x 24 mm) |
| Weight | 1.4 oz (40 g) |
| Power Battery type | 3.6 V, 2400 mAh Lithium |
| Power Battery life | 3 years typical |
| Bluetooth Type | Low Energy 4.1 |
| Bluetooth Sensor to Gateway Range (during a session) | within -75 dpi signal strength; 25m line-of-sight signal strength is viewable in Fluke Connect mobile app |
| Bluetooth Frequency range | 2405 MHz to 2480 MHz |
| Bluetooth Output power | <10 mW |
| Bluetooth IP Rating | IP 67 |