Continuous oil-mist concentration monitoring for two-stroke and four-stroke marine diesel engine crankcases.
| Function | 4-channel base unit, MEPC.107(49) compliant |
| Detection principle | light-extinction across a sampling cell |
| Response time | < 5 s to threshold |
| Alarm output | volt-free changeover contact, configurable per channel |
| Power | 24 V DC nominal, redundant supply |
| Hazardous area | Ex e for sampling head, IP54 for cabinet |
| Environment | 0 to +60 °C engine-room |
| Approval | MSC/Circ.1321 + IACS UR M10 type-approved family |
| Communication | Modbus RTU / Ethernet IAS integration |
| Material | Powder-coated steel cabinet / 316SS sampling head |
| MOQ | 1 ea |
Form-fit envelope of Schaller VN/115/93, Daihatsu MD-220, Kidde Marine FIRE-OMD, Specs SafetyNet ZN and Graviner Mk7 oil-mist detector families. Sampling heads and pipes interchange across engine builders on the same nominal pickup thread.