Analog input and output module; 4 In/O (178791)

Eaton · Control & Automation · PLCs & Industrial Networking · Ireland · eaton.com
Part Number
178791  ·  HS 8538.90
Analog input and output module; 4 In/O (178791)

Eaton 178791 Analog input module; 8 thermocouple inputs and to KTY inputs.

Technical Specifications

Manufacturer part number (MPN)178791
EAN / GTIN7640130098251
Sales unitpcs
Eaton catalogue number178791
Depth104.2 mm
Height16.8 mm
Width80.3 mm
Weight0.061 kg
CertificationsUL File No.: E135462; CE; cULus; EN 61131-2; EN 61000-6-2; EN 61000-6-4; UL508; CSA-C22.2 No. 142-M
Height of fall (IEC/EN 60068-2-32) - max1 m
Mounting positionHorizontal
Shock resistance15 g, Mechanical, Half-sinusoidal shock 11 ms, 18 Impacts
Vibration resistance5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g
Air pressure795 - 1080 hPa (operation)
Ambient operating temperature - max60 °C
Ambient storage temperature - max85 °C
Ambient operating temperature - min0 °C
Ambient storage temperature - min-20 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-3; Dry heat to IEC 60068-2-2
Environmental conditionsCondensation: prevent with appropriate measures
Relative humidity0 - 95 % (non-condensing)
Connection type2 conductors, Voltage measurement; 2 conductors, Analog outputs, Output voltage; Push-in spring-cage terminal (plug-in connection), Connection design in TOP direction
ProtocolOther bus systems
Heat dissipation per pole, current-dependent Pvid1.21 W
Static heat dissipation, non-current-dependent Pvs2.495 W
Rated control supply voltage10 V (Sensor/transmitter supply)
Rated operational current (Ie)Max. 0.0167 A (supply output)
Rated operational voltage160 V (terminations)
Short-circuit current30 mA, per channel, Analog outputs
Short-circuit protectionYes, Short-circuit strength, Analog outputs
Supply voltage at DC - max30 VDC
Supply voltage at DC - min18 VDC
Air discharge8 kV
Burst impulse2 kV, Supply cable; 1 kV, Signal cable
Contact discharge4 kV
Electromagnetic fields1 V/m at 2 - 2.7 GHz (according to IEC EN 61000-4-3); 10 V/m at 0.08 - 1.0 GHz (according to IEC EN 61000-4-3); 3 V/m at 1.4 - 2 GHz (according to IEC EN 61000-4-3)
Emitted interference40 dB (at 30 - 230 MHz, Class A, radiated, high frequency); 47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
Radiated RFI10 V
Surge rating1 kV, Signal cable, unbalanced, EMC; 0.5/0.5 kV, Supply cable, balanced/unbalanced), EMC
Voltage dipsVoltage dips: 10 ms/Voltage fluctuations: Yes
Electric connection typePlug-in connection
FeaturesAnalog outputs configurable; Output, voltage; Input, voltage; Analog inputs configurable; Input signal, configurable
Fitted with1 kHz, third-order low-pass input filter; Parameterizable Software input filter
Value representationSIGNED16, mV, Voltage measurement
Voltage measurement> 10 MΩ, Input resistance; The channels can also be used as potentiometer inputs.; -10 - 10 V DC, Measurement range; Open wire monitoring.; ± 12 V DC, Common-mode range
Current consumption60 mA (typ.), for +24 V, Power supply - Input; 50 mA (typ.), for +5 V power supply (internal), Power supply - Input
Degree of protectionIP20; NEMA 1
Limit frequency1 kHz (third-order low-pass filter)
Mounting methodRail mounting possible
Number of channels4, Analog Inputs
Overvoltage categoryIII
Pollution degree3
Product categoryXN-322 analog input and output module
Resolution12 Bit (Analog outputs) 16 Bit (Analog inputs)
TypeAnalog mixed module with 4 analog outputs -10 - +10 V (16 bit) and 4 analog inputs -10 - +10 V (12 bit) or potentiometer inputs (0-100%, reference output (+10 V/10 mA). XN300 I/O slice module
Used withXN300; XN-312-…
Voltage typeDC
Accuracy± 0.5 % of full scale, Analog outputs; ± 0.3 % of full scale, Voltage measurement
Capacitive load0.1 µF, Analog outputs
Input4 Analog inputs (±10 V, Uref)
Input voltageMax. 14 V DC
Load currentNot specified by plug manufacturer
Measured variablesVoltage or potentiometer
Number of inputs (analog)4
Number of outputs (analog)4
Output4 Analog Outputs (±10 V)
Output voltage-10 - 10 V DC (analog outputs)
Refresh time1 ms (analog inputs, all channels)
Resistive load> 5000 Ω, analog outputs
Value refresh time/cycle timeMin. 1 / 1 ms (per channel / all channels), Analog Inputs
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationAnalog inputs: no; Sensor/transmitter supply: no
Gauge pinA1 (according to IEC/EN 60947-1)
Insulating material groupI
Stripping length (main cable)10 mm
Power consumption1.8 W
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Supporting protocol for EtherCATNo
Supply voltage DC18–30 V
Input, currentNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableYes
Resolution of the analogue inputs16 Bit
Output, currentNo
Output signal configurableNo
Resolution of the analogue outputs12 Bit
Number of analogue inputs4
Number of analogue outputs4
Analogue inputs configurableYes
Analogue outputs configurableYes
Number of HW-interfaces other1
Supporting protocol for TCP/IPNo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ASINo
Supporting protocol for KNXNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for LONNo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFINET CBANo
Supporting protocol for SERCOSNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for INTERBUS-SafetyNo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supporting protocol for other bus systemsYes
Radio standard BluetoothNo
Radio standard WLAN 802.11No
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
IO link masterNo
System accessoryYes
Type of electric connectionPlug-in connection
Fieldbus connection over separate bus coupler possibleNo
Suitable for rail mountingYes
Wall mounting/direct mountingNo
Front built-in possibleNo
Rack-assembly possibleNo
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originAustria

Properties

MOQ1

Cross-References