| Manufacturer part number (MPN) | XNE-8DO-24VDC-0.5A-P |
| EAN / GTIN | 7640130120563 |
| Sales unit | pcs |
| Eaton catalogue number | 140036 |
| Depth | 129.5 mm |
| Height | 74.5 mm |
| Width | 13 mm |
| Weight | 0.055 kg |
| Drop and topple | According to IEC 60068-2-31, free fall according to IEC 60068-2-32 |
| Shock resistance | Continuous according to IEC/EN 60068-2-29; Mechanical, According to IEC/EN 60068-2-27 |
| Vibration resistance | According to IEC/EN 60068-2-6 |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 85 °C |
| Ambient operating temperature - min | 0 °C |
| Ambient storage temperature - min | -25 °C |
| Environmental conditions | Harmful gasses - SO2: 10 ppm (relative humidity < 75%, no condensation); Harmful gasses - H2S: 1 ppm (relative humidity < 75%, no condensation) |
| Relative humidity | 5 - 95 % (indoor, Level RH-2, non-condensing for storage at 45°C) |
| Connection type | Push-In spring-cage terminals, Connection design in TOP direction |
| Protocol | Other bus systems |
| Static heat dissipation, non-current-dependent Pvs | 1.5 W |
| Power loss | 1.5 W |
| Rated operational voltage | 24 V DC (supply terminal) |
| Short-circuit protection | Short-circuit proof, Short-circuit rating, Digital outputs |
| Short-circuit release | Automatic, Ii, Reset after short-circuit rectified, Digital outputs |
| Supply voltage at DC - max | 30 VDC |
| Supply voltage at DC - min | 18 VDC |
| Air discharge | According to EN 61100-4-2 |
| Burst impulse | According to IEC/EN 61000-4-4 |
| Contact discharge | According to EN 61100-4-2 |
| Electromagnetic fields | According to IEC EN 61100-4-2 |
| Emitted interference | 230 - 1000 MHz (radiated, high frequency, according to EN 55016-2-3); 30 - 230 MHz (radiated, high frequency, according to EN 55016-2-3) |
| Radiated RFI | IEC/EN 61100-4-6 |
| Surge rating | According to IEC/EN 61000-4-5 Level 4 |
| Voltage dips | According to EN 61131-2 (Voltage fluctuations/voltage dips) |
| Electric connection type | Plug-in connection |
| Features | Fieldbus connection over separate bus coupler possible |
| Fitted with | Connectable sensors for inductive loads; Connectable sensors for resistive loads; Connectable sensors for lamp loads |
| Functions | Short-circuit protection, outputs available; Positive switching |
| Current consumption | 15 mA, from module bus, Analog input modules; 3 mA, from supply terminal |
| Degree of protection | IP20 |
| Mounting method | Rail mounting possible |
| Operating frequency | As per DC13 to IEC 60947-5-1 at inductive load |
| Product category | XNE Slice module |
| Switching frequency | 100 Hz, with resistive load, Digital outputs; 10 Hz, with lamp load, Digital outputs |
| Type | XI/ON I/O module |
| Voltage type | DC |
| Number of channels | 8 |
| Delay time | 300 µs, Digital outputs, Delay on signal change and resistive load, from High to Low signal; 300 µs, Digital outputs, Delay on signal change and resistive load, from Low to High signal |
| Lamp load | ≤ 6 W (at RLL) |
| Load resistance | ≥ 48 Ω; According to DC13 to IEC 60947-5-1 |
| Number of inputs (digital) | 0 |
| Number of outputs (digital) | 8 |
| Output | 8 Digital Outputs (24 V DC, 0.5 A) |
| Output current | < 1 A (high level, permissible range); 0.5 A |
| Output voltage | 23 V DC (Digital outputs) |
| Utilization factor | 100 % |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Through optocoupler: yes |
| Gauge pin | A1 (according to IEC/EN 60947-1) |
| Stripping length (main cable) | 8 mm |
| Terminal capacity | 0.25 - 1.5 mm², flexible without ferrule, H07V-K; 0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight); 0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight); 0.25 - 1.5 mm², solid, H07V-U |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Supply voltage DC | 18–30 V |
| Number of digital outputs | 8 |
| Digital inputs configurable | No |
| Digital outputs configurable | No |
| Type of voltage (input voltage) | DC |
| Type of digital output | Transistor |
| Permitted voltage at output | 0–30 V |
| Type of output voltage | DC |
| Short-circuit protection, outputs available | Yes |
| Number of HW-interfaces other | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | No |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Type of electric connection | Plug-in connection |
| Time delay at signal change | 0.2–0.3 ms |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | No |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |