cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton XIOC-2AO-U2 Analog Output Module, 2 Outputs +/-10 V

Eaton · Control & Automation · PLCs · Ireland · eaton.com
Part Number
XIOC-2AO-U2  ·  HS 8537.10
Eaton XIOC-2AO-U2 Analog Output Module, 2 Outputs +/-10 V

Eaton XIOC-2AO-U2 analog output expansion module with two configurable +/-10 V outputs for XC100/200 PLC systems.

Technical Specifications

Manufacturer part number (MPN)XIOC-2AO-U2
EAN / GTIN4015082579043
Sales unitpcs
Eaton catalogue number257904
Depth100 mm
Height95 mm
Width30 mm
Weight0.135 kg
CertificationsCSA; UL; UL Category Control No.: NRAQ; UL File No.: E135462; CSA Class No.: 2252-01; CSA File No.: 012528; UL508; CE; IEC/EN 61131-2; CSA-C22.2 No. 0-M; EN 50178; CSA-C22.2 No. 142-M
Impact resistance500 g/⌀ 50 mm ±25 g
Shock resistance15 g, Mechanical, Shock duration 11 ms
Vibration resistance57 - 150 Hz ± 1.0 mm; 10 - 57 Hz, ± 0.075 mm
Ambient operating temperature - max55 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min0 °C
Ambient storage temperature - min-25 °C
Connection typePlug-in terminal block, Outputs; 2-core screened cable (≤ 20 m), Outputs
Static heat dissipation, non-current-dependent Pvs0.5 W
Power lossMax. 0.5 W
Power supply24 V DC (-15/+20 %), approx. 150 mA
Rated operational voltage24 (12) V DC
Supply voltage at DC - max24 VDC
Emitted interferenceClass A (according to DIN/EN 55011/22)
Voltage dips10 ms
Electric connection typeScrew-/spring clamp connection
FeaturesOutput, voltage; Analog outputs configurable; Analog inputs configurable
Admissible range20.4 – 28.8 V (11.8 – 14.4 V), Power supply
Current consumption100 mA, external, Outputs
Degree of protectionIP20
Overvoltage categoryII
Pollution degree2
Protection class1
Repetition rate1 s
Residual ripple≤ 5 %
Resolution12 Bit
TypeAnalog module
Used withXC100/200 (expandable with up to 15 XI/OC modules)
Conversions≤ 5 ms, Inputs
Load resistance≤ 10 kΩ
Number of inputs (analog)0
Number of outputs (analog)2
Output2 Outputs (± 10 V); Outputs
Output voltage-10 - 10 V DC; 2
Total error≤ ±1 % (of the full-scale value), Outputs
Explosion safety category for dustNone
Explosion safety category for gasNone
Potential isolationCircuit within each channel: Opto-isolated
TerminalsOptionally, screw terminals or spring-loaded terminals for digital/analog modules
Number of analogue outputs2
Analogue inputs configurableYes
Analogue outputs configurableYes
Input, currentNo
Input, voltageNo
Input, resistorNo
Input, resistance thermometerNo
Input, thermocoupleNo
Input signal, configurableNo
Output, currentNo
Output signal configurableNo
Resolution of the analogue outputs12 Bit
Type of electric connectionScrew-/spring clamp connection
Suitable for safety functionsNo
SIL according to IEC 61508None
Performance level according to EN ISO 13849-1None
Appendant operation agent (Ex ia)No
Country of originJapan

Properties

MOQ1

Cross-References

Attached Documents