| Manufacturer part number (MPN) | EU5E-SWD-2A2A |
| EAN / GTIN | 4015081405930 |
| Sales unit | pcs |
| Eaton catalogue number | 144063 |
| Depth | 102 mm |
| Height | 90 mm |
| Width | 35 mm |
| Weight | 0.09 kg |
| Certifications | UL Category Control No.: NKCR; IEC/EN 61131-2; UL; CSA; UL File No.: E29184; CSA Class No.: 3211-07; CSA File No.: 2324643 |
| Catalog Notes | alog outputs 0?10V or 0?20 mA |
| Constant acceleration | 1 g, 8.4 - 150 Hz, according to IEC/EN 61131-2, Vibrations |
| Constant amplitude | 3,5 mm, 5 - 8.4 Hz, according to IEC/EN 61131-2, Vibrations |
| Drop and topple | 50 mm Drop height, Drop to IEC/EN 60068-2-31 |
| Height of fall (IEC/EN 60068-2-32) - max | 0.3 m |
| Mounting position | As required |
| Shock resistance | 15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts |
| Air pressure | 795 - 1080 hPa (operation) |
| Ambient operating temperature - max | 55 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-3; Dry heat to IEC 60068-2-2 |
| Environmental conditions | Condensation: prevent with appropriate measures |
| Operating temperature - max | 55 °C |
| Operating temperature - min | -25 °C |
| Relative humidity | 5 - 95 % (non-condensing, IEC/EN 60068-2-30) |
| Connection to SmartWire-DT | Yes |
| Connection type | Plug, 8-pole, SmartWire-DT; Push in terminals |
| Supply and I/O sensor; Connection plug | external device plug SWD4-8SF2-5, SmartWire-DT |
| Data transfer rate | Setting automatically; 250 kBit/s, SmartWire-DT |
| LED indicator | Status indication of SmartWire-DT network: Green LED |
| Protocol | Other bus systems |
| Station | SmartWire-DT slave, SmartWire-DT network |
| Static heat dissipation, non-current-dependent Pvs | 1.5 W |
| Input current | 0 - 20 mA (Analog inputs) |
| Input voltage | 0 - 10 V (Analog inputs) |
| Output current | 0 - 20 mA, Analog outputs; Max. 10 mA |
| Output voltage | 0 - 10 V (analog outputs) |
| Power loss | 1.5 W |
| Rated operational voltage | 24 V DC (-15 %/+ 20 % - power supply) |
| Short-circuit protection | Yes, Short-circuit proof, Analog outputs |
| Air discharge | 8 kV, according to IEC 61131-2, level 3, ESD |
| Burst impulse | 2 kV, Signal cable, according to IEC/EN 61131-2, Level 3; 2 kV, Supply cable, according to IEC/EN 61131-2, Level 3; 2 kV, SmartWire-DT cable, according to IEC/EN 61131-2, Level 3 |
| Contact discharge | 4 kV, according to IEC/EN 61131-2, Level 2, ESD |
| Electromagnetic fields | 1 V/m at 2.0 - 2.7 GHz (according to IEC/EN 61131-2:2008); 10 V/m at 80 - 1000 MHz (according to IEC/EN 61131-2:2008); 3 V/m at 1.4 - 2 GHz (according to IEC/EN 61131-2:2008) |
| Radiated RFI | 10 V (IEC/EN 61131-2:2008, Level 3) |
| Radio interference class | Class B (EN 55011) |
| Surge rating | 1 kV, Surge power cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC; 1 kV, Surge I/O cables, Surge (IEC/EN 61131-2:2008, Level 1), EMC |
| Electric connection type | Flat plug-in connection |
| Features | Output, current; Fieldbus connection over separate bus coupler possible; Input, current; Analog outputs configurable; Output signal configurable; Input, voltage; Output, voltage; Analog inputs configurable; Fieldbus connection over separate bus coupler possible |
| Functions | Adjustable parameter settings; For connection of analog I/O signals |
| Current consumption | 22 mA, SmartWire-DT network |
| Degree of protection | IP20; NEMA 1 |
| Mounting method | Wall mounting/direct mounting; Top-hat rail fixing (according to IEC/EN 60715, 35 mm); Rail mounting possible |
| Overvoltage category | II |
| Pollution degree | 2 |
| Product category | SmartWire-DT slave |
| Repetition accuracy | 0.5 % (Analog inputs); 0.5 % (Analog outputs) |
| Residual ripple | ≤ 5 % (input voltage) |
| Terminal capacity | 0.25 - 1.5 mm² (24 - 16 AWG), flexible with ferrule, Terminal for I/O sensor; 0.2 - 1.5 mm² (AWG 24 - 16), solid, Terminal for I/O sensor |
| Type | Analog modules Analog outputs |
| Voltage type | DC |
| Conversions | 20 ms, Analog inputs; 20 ms, Analog outputs |
| Dielectric strength | 30 kV/mm, according to IEC 60243-1 |
| Input | Current; Inputs configurable (0 - 10 V, 0 - 20 mA); Voltage |
| Input impedance | < 250 Ω |
| Load resistance | < 500 Ω |
| Number of inputs (analog) | 2 |
| Number of outputs (analog) | 2 |
| Output | Outputs configurable (0 - 10 V, 0 - 20 mA) |
| Resolution | 12 Bit (Analog inputs) 12 Bit (Analog outputs) |
| Total error | ± 1 %, Outputs; ± 1 %, Inputs |
| Explosion safety category for dust | None |
| Explosion safety category for gas | None |
| Potential isolation | Inputs for SmartWire-DT: yes; Outputs to SmartWire-DT: yes |
| Protection against polarity reversal | Yes; Yes, for supply voltage (Siemens MPI optional) |
| Power consumption | 1.5 W |
| Certified for UL hazardous location division 1 | No |
| Certified for UL hazardous location division 2 | No |
| Certified for UL hazardous location group A (acetylene) | No |
| Certified for UL hazardous location group B (hydrogen) | No |
| Certified for UL hazardous location group C (ethylene) | No |
| Certified for UL hazardous location group D (propane) | No |
| Certified for UL hazardous location group E (metal dusts) | No |
| Certified for UL hazardous location class I | No |
| Certified for UL hazardous location class II | No |
| Certified for UL hazardous location class III | No |
| Supporting protocol for EtherCAT | No |
| Input, resistor | No |
| Input, resistance thermometer | No |
| Input, thermocouple | No |
| Input signal, configurable | No |
| Resolution of the analogue inputs | 12 Bit |
| Output signal configurable | Yes |
| Resolution of the analogue outputs | 12 Bit |
| Number of analogue inputs | 2 |
| Number of analogue outputs | 2 |
| Analogue inputs configurable | Yes |
| Analogue outputs configurable | Yes |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for ASI | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | No |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for LON | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for SERCOS | No |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for EtherNet/IP | No |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for INTERBUS-Safety | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Supporting protocol for other bus systems | Yes |
| Radio standard Bluetooth | No |
| Radio standard WLAN 802.11 | No |
| Radio standard GPRS | No |
| Radio standard GSM | No |
| Mobile communications standard 3G (UMTS) | No |
| IO link master | No |
| System accessory | Yes |
| Type of electric connection | Flat plug-in connection |
| Fieldbus connection over separate bus coupler possible | Yes |
| Suitable for rail mounting | Yes |
| Wall mounting/direct mounting | Yes |
| Front built-in possible | No |
| Rack-assembly possible | No |
| Suitable for safety functions | No |
| SIL according to IEC 61508 | None |
| Performance level according to EN ISO 13849-1 | None |
| Appendant operation agent (Ex ia) | No |
| Country of origin | Germany |