cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Modular PLC XC204 (XC-204-C11-003)

Eaton · Control & Automation · PLCs · Ireland · eaton.com
Part Number
XC-204-C11-003  ·  HS 8537.10
Modular PLC XC204 (XC-204-C11-003)

Eaton XC-204-C11-003 Modular PLS XC204, Micro PLS, programmable CODESYS 3, USB, Ethernet, CAN, RS485, XN300 IO expandable.

Technical Specifications

Manufacturer part number (MPN)XC-204-C11-003
EAN / GTIN4015081997626
Sales unitpcs
Package quantity3 pcs
Eaton catalogue number199974
Depth104.2 mm
Height29.3 mm
Width80.3 mm
Weight0.11 kg
CertificationsUL listed; EN 61131; EAC; UL File No.: E205091; CE; cULus Listed
Mounting positionVertical (on horizontal top-hat rail)
Shock resistance15 g, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 11 ms, 9 Impacts
Vibration resistance5 - 8.4 / 8.4 -150 Hz, 3,5 mm / 1 g
Air pressure795 - 1080 hPa (operation)
Ambient operating temperature - max60 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-20 °C
Ambient storage temperature - min-25 °C
Relative humidity< 95 % (non-condensing)
InterfacesETH; CAN; RS485; XN300
ProtocolCAN; EtherNet/IP; MODBUS; Other bus systems; TCP/IP
Heat dissipation detailsThe max. heat dissipation is specified as the maximum power produced inside the device's housing.
Static heat dissipation, non-current-dependent Pvs6.3 W
Emitted interference40 dB (at 30 - 230 MHz, Class A, radiated, high frequency); 47 dB (at 230 - 1000 MHz, Class A, radiated, high frequency)
Fitted withXSOFT-CODESYS 3
FunctionsAdditional program memory possible
Connection typePush-in spring-cage terminal, Connection design in TOP direction
Degree of protectionIP20
ModelModular
Mounting methodRail mounting possible
Overvoltage categoryII
Pollution degree2
Voltage typeDC
Number of channels0
Number of inputs (analog)0
Number of inputs (digital)0
Number of outputs (analog)0
Number of outputs (digital)0
Number of relay outputs0
Rated operational current (Ie)1.4 A (supply input)
Supply voltage at DC - max30 VDC
Supply voltage at DC - min19.2 VDC
Voltage dips20 ms; 10 ms
Explosion safety category for dustNone
Explosion safety category for gasNone
Memory capacity512,000 kByte
Terminal capacity0.25 - 0.75 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Terminal capacity (AWG)24 - 16
Terminal capacity (flexible with ferrule)0.25 - 1.5 mm², with ferrules without plastic collar according to DIN 46228-1 (ferrules crimped gas-tight); 0.25 - 1.5 mm², with ferrules with plastic collar according to DIN 46228-1 (ferrules crimped gas-tight)
Terminal capacity (flexible)0.2 - 1.5 mm², H 07V-K
Terminal capacity (solid)0.2 - 1.5 mm², H07V-U
With displayNo
Suitable for safety functionsNo
Type of memoryRAM
Memory size512000 kByte
Processing time (1K, binary operation)0.00125 ms
Supporting protocol for LONNo
Number of HW-interfaces industrial Ethernet1
Number of HW-interfaces RS-4851
Number of HW-interfaces USB1
Number of HW-interfaces other2
With optical interfaceNo
Additional program memory possibleYes
Supporting protocol for TCP/IPYes
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANYes
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
RedundancyNo
Suitable for rail mountingYes
System accessoryYes
Appendant operation agent (Ex ia)No
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Front built-in possibleNo
Rack-assembly possibleNo
Wall mounting/direct mountingNo
Radio standard BluetoothNo
Radio standard WLAN 802.11No
IO link masterNo
Max. number of time switches1000
Performance level according to EN ISO 13849-1None
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Supply voltage DC19.2–30 V
Radio standard GPRSNo
Radio standard GSMNo
Mobile communications standard 3G (UMTS)No
Long-Term Evolution (LTE)No
SIL according to IEC 61508None
Supporting protocol for IEC 61850 EthernetNo
Supporting protocol for DNP3No
Supporting protocol for IEC 60870No
Mobile communications standard 4G (LTE)No
Supporting protocol for EtherCATNo
Certified for UL hazardous location class INo
Certified for UL hazardous location class IINo
Certified for UL hazardous location class IIINo
Certified for UL hazardous location division 1No
Certified for UL hazardous location division 2No
Certified for UL hazardous location group A (acetylene)No
Certified for UL hazardous location group B (hydrogen)No
Certified for UL hazardous location group C (ethylene)No
Certified for UL hazardous location group D (propane)No
Certified for UL hazardous location group E (metal dusts)No
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents