cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton Pluggable N1 load-break switch 63A 3-Pole

Eaton · Switchgear & Protection · Disconnect Switches · Ireland · eaton.com
Part Number
N1-63-SVE  ·  HS 8536.90
Eaton Pluggable N1 load-break switch 63A 3-Pole

Eaton N1-63-SVE Pluggable N1 load-break switch 63A 3-pole.

Technical Specifications

Manufacturer part number (MPN)N1-63-SVE
EAN / GTIN4015081132690
HS code8536.90
Sales unitpcs
Eaton catalogue number113729
Depth90 mm
Height201 mm
Width95 mm
Weight1.023 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947; IEC
FunctionsDisconnectors/main switches; Interlockable; Voltage release optional
Accessories requiredNZM2-XSVS socket base
Amperage Rating63 A
ApplicationUse in unearthed supply systems at 690 V
Circuit breaker frame typeN1
FeaturesVersion as maintenance-/service switch; Version as emergency stop installation; Version as main switch
Number of polesThree-pole
Special featuresMain switch characteristics including positive drive to IEC/EN 60204 and VDE 0113. Isolating characteristics to IEC/EN 60947-3 and VDE 0660. Busbar tag shroud to VDE 0160 Part 100. Rated current = rated uninterrupted current: 63 A
TypeSwitch-disconnector
Ambient operating temperature - max70 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent4.52 W
Rated operational current for specified heat dissipation (In)63 A
Direction of incoming supplyAs required
Electrical connection type of main circuitFrame clamp
Handle typeRocker lever
Isolation300 V AC (between the auxiliary contacts); 500 V AC (between auxiliary contacts and main contacts)
Lifespan, electrical1000 operations at 415 V AC-23A; 7500 operations at 690 V AC-1; 1000 operations at 400 V AC-23A; 10000 operations at 400 V AC-1; 10000 operations at 415 V AC-1; 1000 operations at 690 V AC-23A
Number of operations per hour - max120
Overvoltage categoryIII
Pollution degree3
Rated conditional short-circuit current with back-up fuse80 kA at 690 V; 63 gG/gL; 100 kA at 400/415 V
Rated conditional short-circuit current with downstream fuse10 kA at 690 V; 63 gG/gL; 100 kA at 400/415 V
Rated impulse withstand voltage (Uimp) at auxiliary contacts6000 V
Rated impulse withstand voltage (Uimp) at main contacts6000 V
Rated insulation voltage (Ui)690 V
Rated operating frequency50 Hz
Rated operating power at AC-23, 400 V30 kW
Rated operating voltage (Ue) at AC - max690 V
Rated operational current160 A (690 V AC-22/23A, making and breaking capacity); 160 A (415 V AC-22/23A, making and breaking capacity)
Rated short-circuit making capacity Icm at 690 V, 50/60 Hz2.8 kA
Rated short-time withstand current (Icw)2 kA
Rated short-time withstand current (t = 0.3 s)2 kA
Rated short-time withstand current (t = 1 s)2 kA
Short-circuit protective device fuses - max125 A gL
Voltage rating690 V - 690 V
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Degree of protectionIP20 (basic protection type, in the area of the HMI devices); Other
Degree of protection (IP), front sideIP20; IP40 (with insulating surround); IP66 (with door coupling rotary handle)
Degree of protection (terminations)IP10 (tunnel terminal); IP00 (terminations, phase insulator and band terminal)
Handle colorBlack
Lifespan, mechanical20000 operations
Mounting MethodPlug-in unit; Ground mounting; Intermediate mounting; Built-in device plug-in technique; Distribution board installation
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of switches1
Protection against direct contactFinger and back-of-hand proof to DIN EN 50274/VDE 0106 part 110
Shock resistance20 g (half-sinusoidal shock 20 ms)
Switch positionsI, +, 0
Terminal capacity (aluminum solid conductor/cable)16 mm² (1x) at tunnel terminal; 10 mm² - 16 mm² (2x) direct at switch rear-side connection; 10 mm² - 16 mm² (1x) direct at switch rear-side connection
Terminal capacity (aluminum stranded conductor/cable)25 mm² - 95 mm² (1x) at 1-hole tunnel terminal
Terminal capacity (copper busbar)Max. 16 mm x 5 mm direct at switch rear-side connection; Min. 12 mm x 5 mm direct at switch rear-side connection; M6 at rear-side screw connection
Terminal capacity (copper solid conductor/cable)6 mm² - 16 mm² (2x) at box terminal; 10 mm² - 16 mm² (1x) at box terminal; 6 mm² - 16 mm² (2x) direct at switch rear-side connection; 16 mm² (1x) at tunnel terminal; 10 mm² - 16 mm² (1x) direct at switch rear-side connection
Terminal capacity (copper strip)Max. 9 segments of 9 mm x 0.8 mm at box terminal; Min. 2 segments of 9 mm x 0.8 mm at box terminal

Properties

MOQ1

Cross-References

Attached Documents