cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton NZMN2-M160

Eaton · Electrical Components · Motor Protection Circuit Breakers · Ireland · eaton.com
Part Number
NZMN2-M160  ·  HS 8536.20
Eaton NZMN2-M160

Technical Specifications

Manufacturer part number (MPN)NZMN2-M160
EAN / GTIN4015082657246
Sales unitpcs
Eaton catalogue number265724
Depth149 mm
Height184 mm
Width105 mm
Weight2.325 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947; IEC
FunctionsMotor protection
Amperage Rating160 A
ApplicationUse in unearthed supply systems at 690 V
Circuit breaker frame typeNZM2
ConnectionScrew
Fitted withThermal protection
Number of polesThree-pole
Release systemThermomagnetic release
TypeCircuit breaker
Ambient operating temperature - max70 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent38.4 W
Rated operational current for specified heat dissipation (In)160 A
Direction of incoming supplyAs required
Electrical connection type of main circuitScrew connection
Handle typeRocker lever
Instantaneous current setting (Ii) - max2240 A
Instantaneous current setting (Ii) - min1280 A
Isolation300 V AC (between the auxiliary contacts); 500 V AC (between auxiliary contacts and main contacts)
Lifespan, electrical7500 operations at 690 V AC-1; 10000 operations at 400 V AC-1; 10000 operations at 415 V AC-1; 6500 operations at 415 V AC-3; 6500 operations at 400 V AC-3; 5000 operations at 690 V AC-3
Number of operations per hour - max120
Overload current setting (Ir) - max160 A
Overload current setting (Ir) - min125 A
Overvoltage categoryIII
Pollution degree3
Rated impulse withstand voltage (Uimp) at auxiliary contacts6000 V
Rated impulse withstand voltage (Uimp) at main contacts8000 V
Rated insulation voltage (Ui)1000 V
Rated operating power at AC-3
230 V45 kW
Rated operating power at AC-3
400 V90 kW
Rated operational current134 A (400 V AC-3)
Rated short-circuit making capacity Icm at 240 V
50/60 Hz187 kA
Rated short-circuit making capacity Icm at 400/415 V
50/60 Hz105 kA
Rated short-circuit making capacity Icm at 440 V
50/60 Hz74 kA
Rated short-circuit making capacity Icm at 525 V
50/60 Hz53 kA
Rated short-circuit making capacity Icm at 690 V
50/60 Hz40 kA
Rated short-time withstand current (t = 0.3 s)1.9 kA
Rated short-time withstand current (t = 1 s)1.9 kA
Short-circuit release non-delayed setting - max2240 A
Short-circuit release non-delayed setting - min1280 A
Short-circuit total breaktime< 10 ms
Utilization categoryA (IEC/EN 60947-2)
Voltage rating690 V - 690 V
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Degree of protectionIP20; IP20 (basic degree of protection, in the operating controls area)
Degree of protection (IP), front sideIP66 (with door coupling rotary handle); IP40 (with insulating surround)
Degree of protection (terminations)IP10 (tunnel terminal); IP00 (terminations, phase insulator and strip terminal)
Lifespan, mechanical20000 operations
Mounting MethodFixed; Built-in device fixed built-in technique
Protection against direct contactFinger and back-of-hand proof to VDE 0106 part 100
Shock resistance20 g (half-sinusoidal shock 20 ms)
Switch off techniqueThermomagnetic
Optional terminalsBox terminal. Connection on rear. Tunnel terminal
Standard terminalsScrew terminal
Terminal capacity (aluminum solid conductor/cable)10 mm² - 16 mm² (1x) direct at switch rear-side connection; 16 mm² (1x) at tunnel terminal; 10 mm² - 16 mm² (2x) direct at switch rear-side connection
Terminal capacity (aluminum stranded conductor/cable)25 mm² - 50 mm² (2x) direct at switch rear-side connection; 25 mm² - 185 mm² (1x) at tunnel terminal; 25 mm² - 50 mm² (1x) direct at switch rear-side connection
Terminal capacity (control cable)0.75 mm² - 2.5 mm² (1x); 0.75 mm² - 1.5 mm² (2x)
Terminal capacity (copper busbar)Min. 16 mm x 5 mm direct at switch rear-side connection; M8 at rear-side screw connection; Max. 24 mm x 8 mm direct at switch rear-side connection
Terminal capacity (copper solid conductor/cable)6 mm² - 16 mm² (2x) at box terminal; 6 mm² - 16 mm² (2x) direct at switch rear-side connection; 10 mm² - 16 mm² (1x) at box terminal; 16 mm² (1x) at tunnel terminal; 10 mm² - 16 mm² (1x) direct at switch rear-side connection
Terminal capacity (copper stranded conductor/cable)25 mm² - 185 mm² (1x) at box terminal; 25 mm² - 70 mm² (2x) direct at switch rear-side connection; 25 mm² - 185 mm² (1x) at 1-hole tunnel terminal; 25 mm² - 185 mm² (1x) direct at switch rear-side connection; 25 mm² - 70 mm² (2x) at box terminal
Terminal capacity (copper strip)Max. 10 segments of 24 mm x 0.8 mm at rear-side connection (punched); Min. 2 segments of 9 mm x 0.8 mm at box terminal; Max. 8 segments of 24 mm x 1 mm (2x) at box terminal; Min. 2 segements of 16 mm x 0.8 mm at rear-side connection (punched); Max. 10 segments of 16 mm x 0.8 mm at box terminal
Rated operation power at AC-3, 400 V90 kW
With integrated auxiliary switchNo
Rated permanent current Iu160 A
With integrated under voltage releaseNo
Rated operating voltage690 V
Overload release current setting125–160 A
Power loss38.4 W
With thermal overload protectionYes
Type of electrical connection of main circuitScrew connection
Type of control elementRocker lever
Rated operation power at AC-3, 230 V45 kW
Rated short-circuit breaking capacity Icu at 400 V
AC35 kA
Adjustment range undelayed short-circuit release1280–2240 A
Phase failure sensitiveNo
Device constructionBuilt-in device fixed built-in technique
Country of originRomania

Properties

MOQ1

Cross-References

Attached Documents