cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton Direct Online Starter (DOL), PKE, Screw Connection (MSC-DE-12-M9(24VDC))

Eaton · Drives & Controllers · Motor Starters · Ireland · eaton.com
Part Number
MSC-DE-12-M9(24VDC)  ·  HS 8536.20
Eaton Direct Online Starter (DOL), PKE, Screw Connection (MSC-DE-12-M9(24VDC))

Eaton MSC-DE-12-M9(24VDC).

Technical Specifications

Manufacturer part number (MPN)MSC-DE-12-M9(24VDC)
EAN / GTIN4015081195527
Sales unitpcs
Eaton catalogue number121742
Depth102 mm
Height198 mm
Width45 mm
Weight0.78 kg
CertificationsVDE 0660; IEC/EN 60947-4-1
AltitudeMax. 2000 m
Ambient operating temperature - max55 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent Pvid2.4 W
Heat dissipation per pole, current-dependent Pvid0.8 W
Rated operational current for specified heat dissipation (In)9 A
Static heat dissipation, non-current-dependent Pvs2.6 W
Rated operational current (Ie)8.5 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V9 A
Rated operational power at AC-3, 220/230 V, 50 Hz2.2 kW
Rated operational power at AC-3, 380/400 V, 50 Hz4 kW
Rated operational voltage230 - 415 V AC
Fitted withShort-circuit release
FunctionsTemperature compensated overload protection
ClassAdjustable
ConnectionScrew terminals
Connection to SmartWire-DTNo
Coordination type1
Cut-out periods - min≤ 500 ms, main conducting paths, AC-4 cycle operation
Degree of protectionIP20; NEMA Other
ModelIEC starter
Mounting methodDIN rail
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)1
Overload release current setting - max12 A
Overload release current setting - min3 A
Overvoltage categoryIII
Pollution degree3
Rated impulse withstand voltage (Uimp)6000 V AC
Suitable forAlso motors with efficiency class IE3
TypeStarter with electronic trip unit
Voltage typeDC
Power consumption (sealing) at DC2.6 W
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Short-circuit current rating (basic rating)5 kA, SCCR (UL/CSA); 200 A, max. CB, SCCR (UL/CSA); 225 A, max. Fuse, SCCR (UL/CSA)
Short-circuit release (Irm) - max186 A
With transformerNo
Power consumption4.5 W
Rated operation power at AC-3, 400 V4 kW
Number of auxiliary contacts as normally open contact1
Suitable for emergency stopNo
Rated operation current Ie8.5 A
Overload release current setting3–12 A
Supporting protocol for LONNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for ModbusNo
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsNo
External reset possibleNo
Suitable for rail mountingYes
Rated control supply voltage DC24 V
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Release classAdjustable
With short-circuit releaseYes
With fuseNo
Type of electrical connection of main circuitScrew connection
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPNo
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Voltage type for actuatingDC
Type of motor starterDirect online starter (DOL)
Rated operation power at AC-3, 230 V, 3-phase2.2 kW
Rated operation current at AC-3, 400 V9 A
Ambient temperature, upper operating limit60 °C
Temperature compensated overload protectionYes
Coordination class according to IEC 60947-4-3Class 1
Country of originGermany

Properties

MOQ1

Cross-References

Attached Documents