| Manufacturer part number (MPN) | DILM7-01(230V50/60HZ)-PI |
| EAN / GTIN | 4015081983452 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Eaton catalogue number | 199644 |
| Depth | 75 mm |
| Height | 68 mm |
| Width | 45 mm |
| Weight | 0.225 kg |
| Certifications | VDE 0660; IEC/EN 60947 |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78 |
| Connection to SmartWire-DT | No |
| Number of main contacts (normally open contact) | 3 |
| Number of auxiliary contacts (normally closed contacts) | 1 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Number of contacts (normally closed contacts) | 1 |
| Number of contacts (normally open contacts) | 0 |
| Number of contacts (normally closed) as main contact | 0 |
| Conventional thermal current Ith (1-pole, enclosed) | 45 A |
| Conventional thermal current Ith (3-pole, enclosed) | 18 A |
| Conventional thermal current Ith at 55°C (3-pole, open) | 21 A |
| Conventional thermal current Ith of main contacts (1-pole, open) | 50 A |
| Rated breaking capacity at 220/230 V | 70 A |
| Rated breaking capacity at 380/400 V | 70 A |
| Rated breaking capacity at 500 V | 50 A |
| Rated breaking capacity at 660/690 V | 40 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 112 A |
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 22 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V | 7 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V | 7 A |
| Rated operational current (Ie) at AC-3, 440 V | 7 A |
| Rated operational current (Ie) at AC-3, 500 V | 5 A |
| Rated operational current (Ie) at AC-3, 660 V, 690 V | 4 A |
| Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V | 5 A |
| Rated operational current (Ie) at AC-4, 440 V | 5 A |
| Rated operational current (Ie) at AC-4, 500 V | 4.5 A |
| Rated operational current (Ie) at AC-4, 660 V, 690 V | 4 A |
| Rated operational current (Ie) at DC-1, 110 V | 20 A |
| Rated operational current (Ie) at DC-1, 220 V | 15 A |
| Rated operational current (Ie) at DC-1, 60 V | 20 A |
| Rated operational power at AC-3, 240 V, 50 Hz | 2.2 kW |
| Rated operational power at AC-3, 380/400 V, 50 Hz | 3 kW |
| Rated operational power at AC-3, 415 V, 50 Hz | 4 kW |
| Rated operational power at AC-4, 220/230 V, 50 Hz | 1 kW |
| Rated operational power at AC-4, 240 V, 50 Hz | 1.5 kW |
| Rated operational power at AC-4, 415 V, 50 Hz | 2.3 kW |
| Rated operational power at AC-4, 440 V, 50 Hz | 2.4 kW |
| Rated operational power at AC-4, 500 V, 50 Hz | 2.5 kW |
| Rated operational power at AC-4, 660/690 V, 50 Hz | 2.9 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Emitted interference | According to EN 60947-1 |
| Interference immunity | According to EN 60947-1 |
| Fitted with | Mirror contact |
| Number of poles | Three-pole |
| Application | Contactors for Motors |
| Connection | Push in terminals |
| Degree of protection | IP20 |
| Lifespan, mechanical | 10,000,000 Operations (AC operated) |
| Operating frequency | 9000 mechanical Operations/h (AC operated) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Contactors |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 6000 V AC |
| Suitable for | Also motors with efficiency class IE3 |
| Utilization category | AC-3: Normal AC induction motors: starting, switch off during running; AC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
| Voltage type | AC |
| Frame size | FS1 |
| Arcing time | 10 ms |
| Drop-out voltage | AC operated: 0.6 - 0.3 x UC, AC operated |
| Duty factor | 100 % |
| Pick-up voltage | 0.8 - 1.1 V AC x Uc |
| Power consumption, pick-up, 50 Hz | 27 VA, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, pick-up, 60 Hz | 25 VA, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, sealing, 50 Hz | 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us; 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us |
| Power consumption, sealing, 60 Hz | 1.2 W, Dual-frequency coil in a cold state and 1.0 x Us; 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us; 3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
| Rated control supply voltage (Us) at AC, 50 Hz - max | 230 V |
| Rated control supply voltage (Us) at AC, 50 Hz - min | 230 V |
| Rated control supply voltage (Us) at AC, 60 Hz - max | 230 V |
| Rated control supply voltage (Us) at AC, 60 Hz - min | 230 V |
| Switching time (AC operated, make contacts, closing delay) - max | 21 ms |
| Switching time (AC operated, make contacts, closing delay) - min | 15 ms |
| Switching time (AC operated, make contacts, opening delay) - max | 18 ms |
| Switching time (AC operated, make contacts, opening delay) - min | 9 ms |
| Safe isolation | 400 V AC, Between the contacts, According to EN 61140; 400 V AC, Between coil and contacts, According to EN 61140 |
| Short-circuit current rating (basic rating) | 5 kA, 25 A max. fuse, SCCR (UL/CSA); 5 kA, 25 A max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 480 V) | 100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA); 65 kA, 16 A max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 600 V) | 100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit protection rating (type 1 coordination) at 400 V | 35 A gG/gL |
| Short-circuit protection rating (type 1 coordination) at 690 V | 20 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 400 V | 20 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 690 V | 16 A gG/gL |
| Screwdriver size | 3.0 x 0.5 mm, Terminal screw; 3 x 0.5 mm, Terminal screw |
| Stripping length (main cable) | 10 mm |
| Terminal capacity (flexible with unisolated ferrule) | 1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm² |
| Terminal capacity (flexible) | 1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm² |
| Terminal capacity (flexible with ultrasonic welded cable end) | 1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm² |
| Terminal capacity (solid) | 1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm² |
| Terminal capacity (flexible with ferrule) | 1 x (0.5 - 2.5) mm²; 2 x (0.5 - 1.5) mm² |
| Terminal capacity (solid/stranded AWG) | 20 - 14 |