Contactor DILM12-01(220V50/60HZ)-PI

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM12-01(220V50/60HZ)-PI  ·  HS 8536.90
Contactor DILM12-01(220V50/60HZ)-PI

Eaton DILM12-01(220V50/60HZ)-PI Contactor, 3-pole, 380 V 400 V 5.5 kW, 1 NC, 220 V 50/60 Hz, AC -Control, PI.

Technical Specifications

Manufacturer part number (MPN)DILM12-01(220V50/60HZ)-PI
EAN / GTIN4015081983544
HS code8536.90
Sales unitpcs
Eaton catalogue number199653
Depth75 mm
Height68 mm
Width45 mm
Weight0.225 kg
CertificationsIEC/EN 60947; VDE 0660
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DTNo
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)1
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed contacts)1
Number of contacts (normally open contacts)0
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)45 A
Conventional thermal current Ith (3-pole, enclosed)18 A
Conventional thermal current Ith at 55°C (3-pole, open)21 A
Conventional thermal current Ith of main contacts (1-pole, open)50 A
Rated breaking capacity at 220/230 V120 A
Rated breaking capacity at 380/400 V120 A
Rated breaking capacity at 500 V100 A
Rated breaking capacity at 660/690 V70 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)144 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V22 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V12 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V12 A
Rated operational current (Ie) at AC-3, 440 V12 A
Rated operational current (Ie) at AC-3, 500 V10 A
Rated operational current (Ie) at AC-3, 660 V, 690 V7 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V7 A
Rated operational current (Ie) at AC-4, 440 V7 A
Rated operational current (Ie) at AC-4, 500 V6 A
Rated operational current (Ie) at AC-4, 660 V, 690 V5 A
Rated operational current (Ie) at DC-1, 110 V20 A
Rated operational current (Ie) at DC-1, 220 V15 A
Rated operational current (Ie) at DC-1, 60 V20 A
Rated operational power at AC-3, 240 V, 50 Hz4 kW
Rated operational power at AC-3, 380/400 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz7 kW
Rated operational power at AC-4, 220/230 V, 50 Hz2 kW
Rated operational power at AC-4, 240 V, 50 Hz2.2 kW
Rated operational power at AC-4, 415 V, 50 Hz3.4 kW
Rated operational power at AC-4, 440 V, 50 Hz3.6 kW
Rated operational power at AC-4, 500 V, 50 Hz3.5 kW
Rated operational power at AC-4, 660/690 V, 50 Hz4.4 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withMirror contact
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionPush in terminals
Degree of protectionIP20
Lifespan, mechanical10,000,000 Operations (AC operated)
Operating frequency9000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)6000 V AC
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-3: Normal AC induction motors: starting, switch off during running
Voltage typeAC
Frame sizeFS1
Arcing time10 ms
Drop-out voltageAC operated: 0.6 - 0.3 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc
Power consumption, pick-up, 50 Hz27 VA, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz25 VA, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz1.2 W, Dual-frequency coil in a cold state and 1.0 x Us; 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz1.2 W, Dual-frequency coil in a cold state and 1.0 x Us; 3.3 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us; 4.2 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Rated control supply voltage (Us) at AC, 50 Hz - max220 V
Rated control supply voltage (Us) at AC, 50 Hz - min220 V
Rated control supply voltage (Us) at AC, 60 Hz - max220 V
Rated control supply voltage (Us) at AC, 60 Hz - min220 V
Switching time (AC operated, make contacts, closing delay) - max21 ms
Switching time (AC operated, make contacts, closing delay) - min15 ms
Switching time (AC operated, make contacts, opening delay) - max18 ms
Switching time (AC operated, make contacts, opening delay) - min9 ms
Safe isolation400 V AC, Between the contacts, According to EN 61140; 400 V AC, Between coil and contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 45 A max. fuse, SCCR (UL/CSA); 5 kA, 45 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V25 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V20 A gG/gL
Screwdriver size3 x 0.5 mm, Terminal screw; 3.0 x 0.5 mm, Terminal screw
Stripping length (main cable)10 mm
Terminal capacity (flexible with unisolated ferrule)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (flexible)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (flexible with ultrasonic welded cable end)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (solid)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (flexible with ferrule)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 1.5) mm²
Terminal capacity (solid/stranded AWG)20 - 14

Properties

MOQ1

Cross-References

Attached Documents