Contactor DILM32-11(RDC24)-PI

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM32-11(RDC24)-PI  ·  HS 8536.90
Contactor DILM32-11(RDC24)-PI

Eaton DILM32-11(RDC24)-PI Contactor, 3-pole, 380 V 400 V 15 kW, 1 N/O, 1 NC, RDC 24: 24 - 27 V DC, DC -Control, PI.

Technical Specifications

Manufacturer part number (MPN)DILM32-11(RDC24)-PI
EAN / GTIN4015081973774
HS code8536.90
Sales unitpcs
Eaton catalogue number199293
Depth115 mm
Height85 mm
Width45 mm
Weight0.546 kg
CertificationsVDE 0660; IEC/EN 60947; UL Listed; CSA certified; UL Category Control No.: NLDX; CE marking; UL File No.: E29096; CSA Class No.: 2411-03
3211-04; CSA File No.012528
Catalog NotesAlso tested according to AC-3e.
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Connection to SmartWire-DTIn conjunction with DIL-SWD SmartWire DT contactor module; Yes
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)1
Number of auxiliary contacts (normally open contacts)1
Number of contacts (normally closed contacts)1
Number of contacts (normally open contacts)1
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)90 A
Conventional thermal current Ith (3-pole, enclosed)36 A
Conventional thermal current Ith at 55°C (3-pole, open)42 A
Conventional thermal current Ith of main contacts (1-pole, open)100 A
Heat dissipation capacity Pdiss0 W
Rated breaking capacity at 220/230 V320 A
Rated breaking capacity at 380/400 V320 A
Rated breaking capacity at 500 V320 A
Rated breaking capacity at 660/690 V180 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)384 A
Rated operational current (Ie) at AC-1, 380 V, 400 V
415 V45 A
Rated operational current (Ie) at AC-3, 220 V, 230 V
240 V32 A
Rated operational current (Ie) at AC-3, 380 V, 400 V
415 V32 A
Rated operational current (Ie) at AC-3
440 V32 A
Rated operational current (Ie) at AC-3
500 V32 A
Rated operational current (Ie) at AC-3, 660 V
690 V18 A
Rated operational current (Ie) at AC-4, 220 V, 230 V
240 V15 A
Rated operational current (Ie) at AC-4
440 V15 A
Rated operational current (Ie) at AC-4
500 V15 A
Rated operational current (Ie) at AC-4, 660 V
690 V12 A
Rated operational current (Ie) at DC-1
110 V40 A
Rated operational current (Ie) at DC-1
220 V40 A
Rated operational current (Ie) at DC-1
60 V40 A
Rated operational power at AC-3, 240 V
50 Hz11 kW
Rated operational power at AC-3, 380/400 V
50 Hz15 kW
Rated operational power at AC-3, 415 V
50 Hz19 kW
Rated operational power at AC-4, 220/230 V
50 Hz4 kW
Rated operational power at AC-4, 240 V
50 Hz4.5 kW
Rated operational power at AC-4, 415 V
50 Hz7.5 kW
Rated operational power at AC-4, 440 V
50 Hz8 kW
Rated operational power at AC-4, 500 V
50 Hz9 kW
Rated operational power at AC-4, 660/690 V
50 Hz10 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withMirror contact; Suppressor circuit in actuating electronics
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionPush in terminals
Degree of protectionIP20
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency5000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-3: Normal AC induction motors: starting, switch off during running
Voltage typeDC
Frame sizeFS2
Arcing time10 ms
Duty factor100 %
Pick-up voltage24 - 27 V DC (RDC 24); 0.7 - 1.2 V DC x Uc; 0.7 - 1.2 V DC x Us
Power consumption (pick-up) at DC12 W
Power consumption (sealing) at DC0.9 W
Rated control supply voltage (Us) at DC - max27 V
Rated control supply voltage (Us) at DC - min27 V
Switching time (DC operated, make contacts, closing delay) - max47 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
Assigned motor power at 115/120 V, 60 Hz
1-phase3 HP
Assigned motor power at 200/208 V, 60 Hz
3-phase10 HP
Assigned motor power at 230/240 V, 60 Hz
1-phase5 HP
Assigned motor power at 230/240 V, 60 Hz
Assigned motor power at 460/480 V, 60 Hz
3-phase20 HP
Assigned motor power at 575/600 V, 60 Hz
3-phase25 HP
Safe isolation400 V AC, Between coil and contacts, According to EN 61140; 400 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 125 A max. fuse CLASS RK5, SCCR (UL/CSA); 5 kA, 125 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 70 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 30 A CLASS RK5, SCCR (UL/CSA); 65 kA, 32 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 70 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 30 A CLASS RK5, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V125 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V35 A gG/gL
Screwdriver size3.0 x 0.5 mm, Terminal screw; 3 x 0.5 mm, Terminal screw
Terminal capacity (flexible with unisolated ferrule)1 x (0.5 - 2.5) mm², Control circuit cables; 2 x (0.5 - 2.5) mm², Control circuit cables; 1 x (1 - 6) mm², Main cables; 2 x (1 - 6) mm², Main cables
Terminal capacity (flexible)1 x (1 - 10) mm²; 1 x (0.5 - 2.5) mm²; 2 x (1-6) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (flexible with ultrasonic welded cable end)1 x (0.5 - 2.5) mm², Control circuit cables; 2 x (0.5 - 2.5) mm², Control circuit cables; 1 x (1 - 10) mm², Main cables; 2 x (1 - 6) mm², Main cables
Terminal capacity (solid)1 x (1 - 6) mm²; 1 x (0.5 - 0.25) mm²; 2 x (0.5 - 2.5) mm², Control circuit cables; 2 x (1 - 6) mm²
Terminal capacity (flexible with ferrule)1 x (0.5 - 1.5) mm², Control circuit cables; 2 x (0.5 - 1.5) mm², Main cables; 1 x (1 - 6) mm²; 2 x (1 - 4) mm²
Terminal capacity (solid/stranded AWG)20 - 14; 18 - 8, Main cables

Properties

MOQ1

Cross-References

Attached Documents