cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor DILM185A/22(RDC240)

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM185A/22(RDC240)  ·  HS 8536.90
Contactor DILM185A/22(RDC240)

Eaton DILM185A/22(RDC240) Contactor, 380 V 400 V 90 kW, 2 N/O, 2 NC, RDC 240: 200 - 240 V DC, DC operated, Screw connection.

Technical Specifications

Manufacturer part number (MPN)DILM185A/22(RDC240)
EAN / GTIN4015081363216
HS code8536.90
Sales unitpcs
Eaton catalogue number139543
Depth158 mm
Height190 mm
Width140 mm
Weight3.54 kg
CertificationsIEC/EN 60947-4-1; CE; CSA; IEC/EN 60947; UL Category Control No.: NLDX; CSA File No.: 2389068; CSA-C22.2 No. 60947-4-1-14; UL; VDE 0660; CSA Class No.: 3211-04; UL 60947-4-1; UL File No.: E29096
Catalog NotesContacts according to EN 50012 Also tested according to AC-3e up to 500 V. Also suitable for motors with efficiency class IE3. Conventional thermal current Ith of main contacts (1-pole, open) at 60°
Conventional thermal current Ith (1-pole, enclosed)613 A
Conventional thermal current Ith (3-pole, enclosed)245 A
Conventional thermal current Ith at 40°C (3-pole, open)337 A
Conventional thermal current Ith at 50°C (3-pole, open)301 A
Conventional thermal current Ith at 55°C (3-pole, open)287 A
Conventional thermal current Ith at 60°C (3-pole, open)275 A
Conventional thermal current Ith of main contacts (1-pole, open)688 A
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-40 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-40 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)2
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid5.33 W
Rated operational current for specified heat dissipation (In)185 A
Static heat dissipation, non-current-dependent Pvs2.1 W
Inrush currentMax. 30 x Ie (peak)
Rated breaking capacity at 1000 V760 A
Rated breaking capacity at 220/230 V2250 A
Rated breaking capacity at 380/400 V2250 A
Rated breaking capacity at 500 V2250 A
Rated breaking capacity at 660/690 V2250 A
Rated insulation voltage (Ui)1000 V
Rated making capacity (cos phi to IEC/EN 60947)2700 A
Rated operational current (Ie)133 A at 690 V (Individual compensation, three-phase capacitors, open); 220 A at up to 525 V (Individual compensation, three-phase capacitors, open)
Rated operational current (Ie) at AC-3
1000 V76 A
Rated operational current (Ie) at AC-3, 220 V, 230 V
240 V185 A
Rated operational current (Ie) at AC-3, 380 V, 400 V
415 V185 A
Rated operational current (Ie) at AC-3
440 V185 A
Rated operational current (Ie) at AC-3
500 V185 A
Rated operational current (Ie) at AC-3, 660 V
690 V150 A
Rated operational current (Ie) at AC-4
1000 V55 A
Rated operational current (Ie) at AC-4, 220 V, 230 V
240 V136 A
Rated operational current (Ie) at AC-4
440 V136 A
Rated operational current (Ie) at AC-4
500 V136 A
Rated operational current (Ie) at AC-4, 660 V
690 V110 A
Rated operational power at AC-3, 1000 V
50 Hz108 kW
Rated operational power at AC-3, 240 V
50 Hz62 kW
Rated operational power at AC-3, 380/400 V
50 Hz90 kW
Rated operational power at AC-3, 415 V
50 Hz110 kW
Rated operational power at AC-3, 440 V
50 Hz115 kW
Rated operational power at AC-3, 500 V
50 Hz132 kW
Rated operational power at AC-3, 690 V
50 Hz140 kW
Rated operational power at AC-4, 1000 V
50 Hz77 kW
Rated operational power at AC-4, 220/230 V
50 Hz41 kW
Rated operational power at AC-4, 240 V
50 Hz45 kW
Rated operational power at AC-4, 415 V
50 Hz80 kW
Rated operational power at AC-4, 440 V
50 Hz85 kW
Rated operational power at AC-4, 500 V
50 Hz96 kW
Rated operational power at AC-4, 660/690 V
50 Hz102 kW
Rated operational voltage (Ue) at AC - max1000 V
Safe isolation1000 V AC, Between coil and contacts, According to EN 61140
Special purpose rating of definite purpose rating2016 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 336 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 1680 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 280 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
AccessoriesFitting options auxiliary contacts: on the side: 2 x DILM1000-XHI(V)11-SI; 2 x DILM1000-XHI11-SA
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Electromagnetic compatibilityDesigned for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
Fitted withSuppressor circuit in actuating electronics
Lifespan, electrical100,000 Operations (at Condensor operation)
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency3000 mechanical Operations/h (DC operated); 200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Shock resistance10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeDC
Drop-out voltageDC operated: 0.2 x US max - 0.6 US min
DC operated; DC operated0.15 x US min - 0.6 US max, DC operated
Duty factor100 %
Pick-up voltage0.7 - 1.2 V DC x Us
Power consumption (pick-up) at DC210 VA
Power consumption (sealing) at DC2.1 W
Power consumption, pick-up
50 Hz210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up
60 Hz210 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing
50 Hz2.1 W, Coil in a cold state and 1.0 x Us
Power consumption, sealing
60 Hz2.1 W, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at DC - max240 V
Rated control supply voltage (Us) at DC - min200 V
Switching time (AC operated, make contacts, closing delay) - max60 ms
Switching time (AC operated, make contacts, opening delay) - max40 ms
Assigned motor power at 200/208 V, 60 Hz
3-phase50 HP
Assigned motor power at 230/240 V, 60 Hz
3-phase60 HP
Assigned motor power at 460/480 V, 60 Hz
3-phase125 HP
Assigned motor power at 575/600 V, 60 Hz
3-phase150 HP
Short-circuit current rating (basic rating)800 A, max. CB, SCCR (UL/CSA); 10 kA, SCCR (UL/CSA); 700 A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)350 A, max. CB, SCCR (UL/CSA); 600 A, Class J, max. Fuse, SCCR (UL/CSA); 65 kA, CB, SCCR (UL/CSA); 100 kA, Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)600 A, Class J, max. Fuse, SCCR (UL/CSA); 50 kA, CB, SCCR (UL/CSA); 350 A, max. CB, SCCR (UL/CSA); 100 kA, Fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 1000 V200 A gG/gL
Short-circuit protection rating (type 1 coordination) at 400 V400 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V315 A gG/gL
Short-circuit protection rating (type 2 coordination) at 1000 V160 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V315 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V250 A gG/gL
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA); P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)250 A, Maximum motor rating (UL/CSA)
Screw sizeM10, Terminal screw, Main connections; M3.5, Terminal screw, Control circuit cables
Screwdriver size2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Terminal capacity (busbar)32 mm width, Main connection
Terminal capacity (copper band)Fixing with flat cable terminal or cable terminal blocks; See terminal capacity for cable terminal blocks
Terminal capacity (flexible with cable lug)50 - 185 mm²
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)1 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)1/0 - 350 MCM, Main cables; 18 - 14, Control circuit cables
Terminal capacity (stranded with cable lug)50 - 185 mm²
Tightening torque24 Nm, Main cable connection screw/bolt; 1.2 Nm, Screw terminals, Control circuit cables
Width across flats16 mm

Properties

MOQ1

Cross-References

Attached Documents