| Manufacturer part number (MPN) | DILL12(24V50HZ) |
| EAN / GTIN | 4015081041787 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Eaton catalogue number | 104401 |
| Depth | 97 mm |
| Height | 85 mm |
| Width | 45 mm |
| Weight | 0.426 kg |
| Certifications | CE; CSA Class No.: 3211-04; UL File No.: E29096; CSA File No.: 012528; IEC/EN 60947; UL 60947-4-1; UL Category Control No.: NLDX; UL; VDE 0660; CSA-C22.2 No. 60947-4-1-14; CSA; IEC/EN 60947-4-1 |
| Shock resistance | 6.9 g, N/O main contact, Mechanical, According to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Altitude | Max. 2000 m |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 |
| Number of main contacts (normally open contact) | 3 |
| Number of auxiliary contacts (normally closed contacts) | 0 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Number of contacts (normally closed) as main contact | 0 |
| Conventional thermal current Ith at 60°C (3-pole, open) | 24 A |
| Equipment heat dissipation, current-dependent Pvid | 1.2 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.4 W |
| Rated operational current for specified heat dissipation (In) | 14 A |
| Static heat dissipation, non-current-dependent Pvs | 2.1 W |
| Permissible compensation capacity | 470 µF |
| Rated breaking capacity at 380/400 V | 170 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity (cos phi to IEC/EN 60947) | 238 A |
| Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V | 12 A |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Emitted interference | According to EN 60947-1 |
| Interference immunity | According to EN 60947-1 |
| Number of poles | Three-pole |
| Application | Contactors for lighting systems |
| Connection | Screw terminals |
| Degree of protection | IP00 |
| Lifespan, electrical | 10,000 Operations |
| Lifespan, mechanical | 1,000,000 Operations (AC operated) |
| Operating frequency | 60 mechanical Operations/h (AC operated); 60 electrical Operations/h |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | DILL Lighting contactors |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Resistance per pole | 2.65 mΩ |
| Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces |
| Voltage type | AC |
| Drop-out voltage | AC operated: 0.6 - 0.3 x UC, AC operated |
| Duty factor | 100 % |
| Pick-up voltage | 0.7 - 1.15 V AC x Us; 0.8 - 1.1 V AC x Uc; 0.7 - 1.15 V DC x Us |
| Power consumption, pick-up, 50 Hz | 52 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz |
| Power consumption, pick-up, 60 Hz | 67 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
| Power consumption, sealing, 50 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz; 7.1 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 50 Hz |
| Power consumption, sealing, 60 Hz | 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 8.7 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz |
| Rated control supply voltage (Us) at AC, 50 Hz - max | 24 V |
| Rated control supply voltage (Us) at AC, 50 Hz - min | 24 V |
| Switching time (AC operated, make contacts, closing delay) - max | 22 ms |
| Switching time (AC operated, make contacts, closing delay) - min | 16 ms |
| Switching time (AC operated, make contacts, opening delay) - max | 14 ms |
| Switching time (AC operated, make contacts, opening delay) - min | 8 ms |
| Short-circuit current rating (basic rating) | 5 kA, SCCR (UL/CSA); 125 A, max. Fuse, SCCR (UL/CSA); 125 A, max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 480 V) | 70 A, Class J, max. Fuse, SCCR (UL/CSA); 100 kA, Fuse, SCCR (UL/CSA); 22 kA, CB, SCCR (UL/CSA); 32 A, max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 600 V) | 70 A, Class J, max. Fuse, SCCR (UL/CSA); 22 kA, CB, SCCR (UL/CSA); 100 kA, Fuse, SCCR (UL/CSA); 32 A, max. CB, SCCR (UL/CSA) |
| Short-circuit protection rating (type 2 coordination) at 400 V | 63 A gG/gL |
| Special purpose rating of tungsten incandescent lamps | 24 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 24 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Switching capacity (main contacts, general use) | 24 A, Maximum motor rating (UL/CSA) |