cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor DILM580/22(RA250)

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM580/22(RA250)  ·  HS 8536.90
Contactor DILM580/22(RA250)

Eaton DILM580/22(RA250) Contactor 3-pole, 110-250 V 40-60Hz/DC incl. 2NO+2NC.

Technical Specifications

Manufacturer part number (MPN)DILM580/22(RA250)
EAN / GTIN4015082082161
HS code8536.90
Sales unitpcs
Eaton catalogue number208216
Depth232 mm
Height296 mm
Width250 mm
Weight16.212 kg
CertificationsIEC/EN 60947; IEC/EN 60947-4-1; CSA-C22.2 No. 60947-4-1-14; UL File No.: E29096; UL; CSA File No.: 012528; UL 60947-4-1; UL Category Control No.: NLDX; CSA Class No.: 3211-04; CE; VDE 0660; CSA
Catalog NotesContacts according to EN 50012 Also tested according to AC-3e up to 690 V. Also suitable for motors with efficiency class IE3. Conventional thermal current Ith of main contacts (1-pole, open) at 60°
Conventional thermal current Ith at 40°C (3-pole, open)980 A
Conventional thermal current Ith at 50°C (3-pole, open)876 A
Conventional thermal current Ith at 55°C (3-pole, open)836 A
Conventional thermal current Ith at 60°C (3-pole, open)800 A
Conventional thermal current Ith of main contacts (1-pole, open)2000 A
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-40 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-40 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)2
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid10.67 W
Rated operational current for specified heat dissipation (In)580 A
Static heat dissipation, non-current-dependent Pvs6.5 W
Inrush currentMax. 30 x Ie (peak)
Rated breaking capacity at 1000 V4350 A
Rated breaking capacity at 220/230 V6500 A
Rated breaking capacity at 380/400 V6500 A
Rated breaking capacity at 500 V6500 A
Rated breaking capacity at 660/690 V6500 A
Rated insulation voltage (Ui)1000 V
Rated making capacity (cos phi to IEC/EN 60947)7800 A
Rated operational current (Ie)265 A at 690 V (Individual compensation, three-phase capacitors, open); 463 A at up to 525 V (Individual compensation, three-phase capacitors, open)
Rated operational current (Ie) at AC-3, 1000 V435 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V580 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V580 A
Rated operational current (Ie) at AC-3, 440 V580 A
Rated operational current (Ie) at AC-3, 500 V580 A
Rated operational current (Ie) at AC-3, 660 V, 690 V580 A
Rated operational current (Ie) at AC-4, 1000 V348 A
Rated operational current (Ie) at AC-4, 220 V, 230 V, 240 V456 A
Rated operational current (Ie) at AC-4, 440 V456 A
Rated operational current (Ie) at AC-4, 500 V456 A
Rated operational current (Ie) at AC-4, 660 V, 690 V456 A
Rated operational power at AC-3, 1000 V, 50 Hz600 kW
Rated operational power at AC-3, 240 V, 50 Hz200 kW
Rated operational power at AC-3, 380/400 V, 50 Hz315 kW
Rated operational power at AC-3, 415 V, 50 Hz348 kW
Rated operational power at AC-3, 440 V, 50 Hz370 kW
Rated operational power at AC-3, 500 V, 50 Hz420 kW
Rated operational power at AC-3, 690 V, 50 Hz560 kW
Rated operational power at AC-4, 1000 V, 50 Hz509 kW
Rated operational power at AC-4, 220/230 V, 50 Hz143 kW
Rated operational power at AC-4, 240 V, 50 Hz156 kW
Rated operational power at AC-4, 415 V, 50 Hz274 kW
Rated operational power at AC-4, 440 V, 50 Hz290 kW
Rated operational power at AC-4, 500 V, 50 Hz330 kW
Rated operational power at AC-4, 660/690 V, 50 Hz440 kW
Rated operational voltage (Ue) at AC - max1000 V
Safe isolation1000 V AC, Between coil and contacts, According to EN 61140
Special purpose rating of definite purpose rating670 A, FLA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 4020 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 670 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 4020 A, LRA 600 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
AccessoriesFitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Electromagnetic compatibilityDesigned for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
Fitted withSuppressor circuit in actuating electronics
Lifespan, electrical100,000 Operations (at Condensor operation)
Lifespan, mechanical5,000,000 Operations (AC operated); 5,000,000 Operations (DC operated)
Operating frequency1000 mechanical Operations/h (AC operated); 1000 mechanical Operations/h (DC operated); 200 Operations/h
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof with terminal shroud or terminal block, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance500 mΩ (Admissible transitional contact resistance - of the external control circuit device when actuating A11)
Shock resistance10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Signal level5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-4: Normal AC induction motors: starting, plugging, reversing, inching; AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Voltage typeAC/DC
Drop-out voltageAC operated: 0.2 x US max - 0.6 x US min, AC operated; 0.2 x US max - 0.6 x US min, DC operated
Duty factor100 %
Pick-up voltage0.7 - 1.15 V AC x Us; 0.7 - 1.15 V DC x Us
Power consumptionControl transformer with uk ≤ 7%
Power consumption, pick-up, 50 Hz1000 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz1000 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz26.5 VA, Coil in a cold state and 1.0 x Us; 11.4 W, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz26.5 VA, Coil in a cold state and 1.0 x Us; 11.4 W, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max250 V
Rated control supply voltage (Us) at AC, 50 Hz - min110 V
Rated control supply voltage (Us) at AC, 60 Hz - max250 V
Rated control supply voltage (Us) at AC, 60 Hz - min110 V
Rated control supply voltage (Us) at DC - max250 V
Rated control supply voltage (Us) at DC - min110 V
Switching time (AC operated, make contacts, closing delay) - max70 ms
Switching time (AC operated, make contacts, opening delay) - max110 ms
Assigned motor power at 200/208 V, 60 Hz, 3-phase200 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase200 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase400 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase600 HP
Short-circuit current rating (basic rating)2000 A, max. Fuse, SCCR (UL/CSA); 1200 A, max. CB, SCCR (UL/CSA); 30 kA, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)85 kA, Fuse, SCCR (UL/CSA); 2000 A, max. Fuse, SCCR (UL/CSA); 1200 A, max. CB, SCCR (UL/CSA); 85 kA, CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)2000 A, max. Fuse, SCCR (UL/CSA); 85 kA, CB, SCCR (UL/CSA); 1200 A, max. CB, SCCR (UL/CSA); 85 kA, Fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 1000 V630 A gG/gL
Short-circuit protection rating (type 1 coordination) at 400 V1000 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V1000 A gG/gL
Short-circuit protection rating (type 2 coordination) at 1000 V500 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V630 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V630 A gG/gL
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300, DC operated (UL/CSA); A600, AC operated (UL/CSA)
Switching capacity (main contacts, general use)980 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw, Control circuit cables; M10, Terminal screw, Main connections
Screwdriver size2, Terminal screw, Control circuit cables, Pozidriv screwdriver
Terminal capacity (busbar)50 mm width, Main connection
Terminal capacity (copper band)Fixing with flat cable terminal or cable terminal blocks; See terminal capacity for cable terminal blocks
Terminal capacity (flexible with cable lug)50 - 240 mm²
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)2/0 - 500 MCM, Main cables; 18 - 14, Control circuit cables
Terminal capacity (stranded with cable lug)70 - 240 mm²
Tightening torque24 Nm, Main cable connection screw/bolt; 1.2 Nm, Screw terminals, Control circuit cables
Width across flats16 mm

Properties

MOQ1

Cross-References

Attached Documents