cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor 4P. 230V 50Hz (DILMP45-10(230V50HZ,240V60HZ))

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILMP45-10(230V50HZ,240V60HZ)  ·  HS 8536.90
Contactor 4P. 230V 50Hz (DILMP45-10(230V50HZ,240V60HZ))

Eaton DILMP45-10(230V50HZ,240V60HZ) Contactor 4-pole, 40A AC1 230VAC incl. 1NO.

Technical Specifications

Manufacturer part number (MPN)DILMP45-10(230V50HZ,240V60HZ)
EAN / GTIN4015081093960
HS code8536.90
Sales unitpcs
Eaton catalogue number109826
Depth97 mm
Height85 mm
Width58 mm
Weight0.49 kg
CertificationsCSA Certified; UL Listed; UL 60947-4-1; CSA-C22.2 No. 60947-4-1-14; UL Category Control No.: NLDX; CSA File No.: 012528; CSA; VDE 0660; IEC/EN 60947; CE; IEC/EN 60947-4-1; UL File No.: E29096; CSA Class No.: 2411-03, 3211-04; UL
Catalog NotesContacts according to EN 50012
Shock resistance7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-3; Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DTNo
Number of main contacts (normally open contact)4
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)1
Number of contacts1 NO
Number of contacts (normally open contacts)1
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)105 A
Conventional thermal current Ith (3-pole, enclosed)36 A
Conventional thermal current Ith at 55°C (3-pole, open)40 A
Conventional thermal current Ith at 60°C (3-pole, open)39 A
Conventional thermal current Ith of main contacts (1-pole, open)117 A
Equipment heat dissipation, current-dependent Pvid13.2 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid4.4 W
Rated operational current for specified heat dissipation (In)45 A
Static heat dissipation, non-current-dependent Pvs2.1 W
Rated breaking capacity at 220/230 V250 A
Rated breaking capacity at 380/400 V250 A
Rated breaking capacity at 500 V250 A
Rated breaking capacity at 660/690 V144 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)350 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V45 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V25 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V25 A
Rated operational current (Ie) at AC-3, 440 V25 A
Rated operational current (Ie) at AC-3, 500 V25 A
Rated operational current (Ie) at AC-3, 660 V, 690 V15 A
Rated operational current (Ie) at DC-1, 110 V45 A
Rated operational current (Ie) at DC-1, 220 V45 A
Rated operational current (Ie) at DC-1, 60 V45 A
Rated operational power at AC-1, 220/230 V, 50 Hz16 kW
Rated operational power at AC-1, 240 V, 50 Hz18 kW
Rated operational power at AC-1, 380/400 V, 50 Hz28 kW
Rated operational power at AC-1, 415 V, 50 Hz31 kW
Rated operational power at AC-1, 440 V, 50 Hz33 kW
Rated operational power at AC-1, 500 V, 50 Hz37 kW
Rated operational power at AC-1, 690 V, 50 Hz49 kW
Rated operational power at AC-3, 240 V, 50 Hz8.5 kW
Rated operational power at AC-3, 380/400 V, 50 Hz11 kW
Rated operational power at AC-3, 415 V, 50 Hz14.5 kW
Rated operational power at AC-3, 440 V, 50 Hz15.5 kW
Rated operational power at AC-3, 500 V, 50 Hz17.5 kW
Rated operational power at AC-3, 690 V, 50 Hz14 kW
Rated operational voltage (Ue) at AC - max690 V
Interference immunityAccording to EN 60947-1
Number of polesFour-pole
ApplicationContactors for 4 pole electric consumers
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical10,000,000 Operations (DC operated); 10,000,000 Operations (AC operated)
Operating frequency5000 mechanical Operations/h (DC operated); 5000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Residual current1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
Resistance per pole2.7 mΩ
TypeFull voltage non-reversing medium contactor
Used withDILM32-XHI( C), DILA-XHI(V)( C)
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Voltage typeAC
Coil voltage230-240 Vac, 50/60 Hz
Drop-out voltageAC operated: 0.6 - 0.4 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc; 0.85 - 1.1 V AC/DC x Us
Power consumption, pick-up, 50 Hz50 VA, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz40 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 50 VA, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz8 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 2.1 W, Dual-frequency coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max230 V
Rated control supply voltage (Us) at AC, 50 Hz - min230 V
Rated control supply voltage (Us) at AC, 60 Hz - max240 V
Rated control supply voltage (Us) at AC, 60 Hz - min240 V
Switching time (AC operated, make contacts, closing delay) - max22 ms
Switching time (AC operated, make contacts, closing delay) - min16 ms
Switching time (AC operated, make contacts, opening delay) - max14 ms
Switching time (AC operated, make contacts, opening delay) - min8 ms
Power consumption11 kW
Assigned motor power at 115/120 V, 60 Hz, 1-phase2 HP
Assigned motor power at 200/208 V, 60 Hz, 3-phase7.5 HP
Assigned motor power at 230/240 V, 60 Hz, 1-phase5 HP
Assigned motor power at 230/240 V, 60 Hz, 3-phase10 HP
Assigned motor power at 460/480 V, 60 Hz, 3-phase15 HP
Assigned motor power at 575/600 V, 60 Hz, 3-phase20 HP
Safe isolation440 V AC, Between coil and contacts, According to EN 61140; 440 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)125 A, max. CB, SCCR (UL/CSA); 5 kA, SCCR (UL/CSA); 125 A, max. Fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)125/70 A, Class J, max. Fuse, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA); 10/100 kA, Fuse, SCCR (UL/CSA); 10/65 kA, CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)125/100 A, Class J, max. Fuse, SCCR (UL/CSA); 10/100 kA, Fuse, SCCR (UL/CSA); 10/22 kA, CB, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V100 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V35 A gG/gL
Special purpose rating of definite purpose rating150 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control14 A, 480 V 60 Hz 3-ph, (UL/CSA); 17 A, 600 V 60 Hz 3-ph, (UL/CSA); 15 HP, 600 V 60 Hz 3-ph, (UL/CSA); 15.2 A, 240 V 60 Hz 3-ph, (UL/CSA); 10 HP, 480 V 60 Hz 3-ph, (UL/CSA); 5 HP, 240 V 60 Hz 3-ph, (UL/CSA); 3 HP, 200 V 60 Hz 3-ph, (UL/CSA); 11 A, 200 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)30 A, FLA 600 V 60 Hz 3phase; (CSA); 240 A, LRA 480 V 60 Hz 3phase; (CSA); 40 A, FLA 480 V 60 Hz 3phase; (CSA); 180 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps40 A (600V 60Hz 3phase, 347V 60Hz 1phase); 40 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300, DC operated (UL/CSA); A600, AC operated (UL/CSA)
Switching capacity (main contacts, general use)40 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw, Control circuit cables; M5, Terminal screw, Main cables
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (flexible)1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm²
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 16) mm², Main cables; 2 x (0.75 - 10) mm², Main cables; 1 x (0.75 - 4) mm², Control circuit cables; 1 x (0.75 - 2.5) mm²
Terminal capacity (stranded)1 x 16 mm², Main cables
TerminalsScrew terminals
Tightening torque3 Nm, Screw terminals, Main cables; 1.2 Nm, Screw terminals, Control circuit cables
Terminal capacity (flexible with ferrule)1 x (0.75 - 1.5) mm²; 2 x (0.75 - 1.5) mm²
Terminal capacity (solid/stranded AWG)18 - 14, Control circuit cables; 18 - 6, Main cables

Properties

MOQ1

Cross-References

Attached Documents