Contactor 4POL 230V50HZ 240V60 (DILMP20(230V50HZ,240V60HZ))

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILMP20(230V50HZ,240V60HZ)  ·  HS 8536.90
Contactor 4POL 230V50HZ 240V60 (DILMP20(230V50HZ,240V60HZ))

Eaton DILMP20(230V50HZ,240V60HZ) Contactor 4-pole, 20A AC1 230VAC.

Technical Specifications

Manufacturer part number (MPN)DILMP20(230V50HZ,240V60HZ)
EAN / GTIN4015082769703
HS code8536.90
Sales unitpcs
Eaton catalogue number276970
Depth75 mm
Height68 mm
Width45 mm
Weight0.235 kg
CertificationsUL File No.: E29096; VDE 0660; UL Category Control No.: NLDX; CSA; CE; IEC/EN 60947; UL; CSA-C22.2 No. 60947-4-1-14; UL 60947-4-1; CSA File No.: 012528; IEC/EN 60947-4-1; CSA Class No.: 2411-03, 3211-04
Catalog NotesContacts according to EN 50012
Shock resistance7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Connection to SmartWire-DTNo
Number of main contacts (normally open contact)4
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)0
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)54 A
Conventional thermal current Ith (3-pole, enclosed)18 A
Conventional thermal current Ith at 55°C (3-pole, open)20.5 A
Conventional thermal current Ith at 60°C (3-pole, open)20 A
Conventional thermal current Ith of main contacts (1-pole, open)60 A
Equipment heat dissipation, current-dependent Pvid3 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid1 W
Rated operational current for specified heat dissipation (In)22 A
Static heat dissipation, non-current-dependent Pvs1.4 W
Rated breaking capacity at 220/230 V120 A
Rated breaking capacity at 380/400 V120 A
Rated breaking capacity at 500 V100 A
Rated breaking capacity at 660/690 V70 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)144 A
Rated operational current (Ie) at AC-1, 380 V, 400 V, 415 V22 A
Rated operational current (Ie) at AC-3, 220 V, 230 V, 240 V12 A
Rated operational current (Ie) at AC-3, 380 V, 400 V, 415 V12 A
Rated operational current (Ie) at AC-3, 440 V12 A
Rated operational current (Ie) at AC-3, 500 V10 A
Rated operational current (Ie) at AC-3, 660 V, 690 V7 A
Rated operational current (Ie) at DC-1, 110 V22 A
Rated operational current (Ie) at DC-1, 220 V6 A
Rated operational current (Ie) at DC-1, 60 V22 A
Rated operational power at AC-1, 220/230 V, 50 Hz8 kW
Rated operational power at AC-1, 240 V, 50 Hz9 kW
Rated operational power at AC-1, 380/400 V, 50 Hz14 kW
Rated operational power at AC-1, 415 V, 50 Hz15 kW
Rated operational power at AC-1, 440 V, 50 Hz16 kW
Rated operational power at AC-1, 500 V, 50 Hz18 kW
Rated operational power at AC-1, 690 V, 50 Hz24 kW
Rated operational power at AC-3, 240 V, 50 Hz4 kW
Rated operational power at AC-3, 380/400 V, 50 Hz5.5 kW
Rated operational power at AC-3, 415 V, 50 Hz7 kW
Rated operational power at AC-3, 440 V, 50 Hz7.5 kW
Rated operational power at AC-3, 500 V, 50 Hz7 kW
Rated operational power at AC-3, 690 V, 50 Hz6.5 kW
Rated operational voltage (Ue) at AC - max690 V
Interference immunityAccording to EN 60947-1
Number of polesFour-pole
ApplicationContactors for 4 pole electric consumers
ConnectionScrew terminals
Degree of protectionIP20
Lifespan, mechanical10,000,000 Operations (AC operated); 10,000,000 Operations (DC operated)
Operating frequency5000 mechanical Operations/h (DC operated); 5000 mechanical Operations/h (AC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Residual current1 mA (with actuation of A1 - A2 by the electronics with "0" signal)
Resistance per pole2.5 mΩ
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces
Voltage typeAC
Drop-out voltageAC operated: 0.6 - 0.4 x UC, AC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc; 0.8 - 1.1 V AC/DC x Us
Power consumption, pick-up, 50 Hz24 VA, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz24 VA, Dual-frequency coil in a cold state and 1.0 x Us; 19 W, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz
Power consumption, sealing, 50 Hz1.4 W, Dual-frequency coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz4 VA, Dual-frequency coil in a cold state and 1.0 x Us, at 60 Hz; 1.4 W, Dual-frequency coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max230 V
Rated control supply voltage (Us) at AC, 50 Hz - min230 V
Rated control supply voltage (Us) at AC, 60 Hz - max240 V
Rated control supply voltage (Us) at AC, 60 Hz - min240 V
Switching time (AC operated, make contacts, closing delay) - max21 ms
Switching time (AC operated, make contacts, closing delay) - min15 ms
Switching time (AC operated, make contacts, opening delay) - max18 ms
Switching time (AC operated, make contacts, opening delay) - min9 ms
Safe isolation400 V AC, Between coil and contacts, According to EN 61140; 400 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 45 A max. fuse, SCCR (UL/CSA); 5 kA, 45 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 60 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V25 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V20 A gG/gL
Special purpose rating of elevator control5 HP, 600 V 60 Hz 3-ph, (UL/CSA); 6.1 A, 600 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)60 A, LRA 480 V 60 Hz 3phase; (CSA); 10 A, FLA 600 V 60 Hz 3phase; (CSA); 10 A, FLA 480 V 60 Hz 3phase; (CSA); 60 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps20 A (480V 60Hz 3phase, 277V 60Hz 1phase); 20 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Switching capacity (main contacts, general use)20 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)1 x (0.75 - 4) mm²; 2 x (0.75 - 2.5) mm²
Tightening torque1.2 Nm, Screw terminals
Terminal capacity (flexible with ferrule)1 x (0.75 - 1.5) mm²; 2 x (0.75 - 1.5) mm²; 1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm²
Terminal capacity (solid/stranded AWG)18 - 14

Properties