| Manufacturer part number (MPN) | DILM12-01(24VDC) |
| EAN / GTIN | 4015082768805 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Eaton catalogue number | 276880 |
| Depth | 75 mm |
| Height | 68 mm |
| Width | 45 mm |
| Weight | 0.296 kg |
| Certifications | IEC/EN 60947; CSA Class No.: 2411-03 |
| 3211-04; CE; VDE 0660; CSA File No. | 012528; UL Category Control No.: NLDX; UL; CSA; IEC/EN 60947-4-1; UL File No.: E29096; UL 508; CSA-C22.2 No. 14-05 |
| Catalog Notes | Contacts according to EN 50012 |
| Altitude | Max. 2000 m |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30 |
| Connection to SmartWire-DT | In conjunction with DIL-SWD SmartWire DT contactor module; Yes |
| Number of main contacts (normally open contact) | 3 |
| Number of auxiliary contacts (normally closed contacts) | 1 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Number of contacts (normally closed contacts) | 1 |
| Number of contacts (normally open contacts) | 0 |
| Number of contacts (normally closed) as main contact | 0 |
| Conventional thermal current Ith (1-pole, enclosed) | 45 A |
| Conventional thermal current Ith (3-pole, enclosed) | 18 A |
| Conventional thermal current Ith at 55°C (3-pole, open) | 21 A |
| Conventional thermal current Ith at 60°C (3-pole, open) | 20 A |
| Conventional thermal current Ith of main contacts (1-pole, open) | 50 A |
| Equipment heat dissipation, current-dependent Pvid | 1.5 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 0.5 W |
| Rated operational current for specified heat dissipation (In) | 12 A |
| Static heat dissipation, non-current-dependent Pvs | 4.5 W |
| Rated breaking capacity at 220/230 V | 120 A |
| Rated breaking capacity at 380/400 V | 120 A |
| Rated breaking capacity at 500 V | 100 A |
| Rated breaking capacity at 660/690 V | 70 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 168 A |
| Rated operational current (Ie) at AC-1, 380 V, 400 V |
| 415 V | 22 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V |
| 240 V | 12 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V |
| 415 V | 12 A |
| Rated operational current (Ie) at AC-3 |
| 440 V | 12 A |
| Rated operational current (Ie) at AC-3 |
| 500 V | 10 A |
| Rated operational current (Ie) at AC-3, 660 V |
| 690 V | 7 A |
| Rated operational current (Ie) at AC-4, 220 V, 230 V |
| 240 V | 7 A |
| Rated operational current (Ie) at AC-4 |
| 440 V | 7 A |
| Rated operational current (Ie) at AC-4 |
| 500 V | 6 A |
| Rated operational current (Ie) at AC-4, 660 V |
| 690 V | 5 A |
| Rated operational current (Ie) at DC-1 |
| 110 V | 20 A |
| Rated operational current (Ie) at DC-1 |
| 220 V | 15 A |
| Rated operational current (Ie) at DC-1 |
| 60 V | 20 A |
| Rated operational power at AC-3, 240 V |
| 50 Hz | 4 kW |
| Rated operational power at AC-3, 380/400 V |
| 50 Hz | 5.5 kW |
| Rated operational power at AC-3, 415 V |
| 50 Hz | 7 kW |
| Rated operational power at AC-3, 440 V |
| 50 Hz | 7.5 kW |
| Rated operational power at AC-3, 500 V |
| Rated operational power at AC-3, 690 V |
| 50 Hz | 6.5 kW |
| Rated operational power at AC-4, 220/230 V |
| 50 Hz | 2 kW |
| Rated operational power at AC-4, 240 V |
| 50 Hz | 2.2 kW |
| Rated operational power at AC-4, 415 V |
| 50 Hz | 3.4 kW |
| Rated operational power at AC-4, 440 V |
| 50 Hz | 3.6 kW |
| Rated operational power at AC-4, 500 V |
| 50 Hz | 3.5 kW |
| Rated operational power at AC-4, 660/690 V |
| 50 Hz | 4.4 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Emitted interference | According to EN 60947-1 |
| Interference immunity | According to EN 60947-1 |
| Fitted with | Mirror contact; Varistor suppressor circuit |
| Number of poles | Three-pole |
| Application | Contactors for Motors |
| Connection | Screw terminals |
| Degree of protection | IP20 |
| Lifespan, mechanical | 10,000,000 Operations (DC operated) |
| Operating frequency | 9000 mechanical Operations/h (DC operated) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Contactors |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Resistance per pole | 4.6 mΩ |
| Suitable for | Also motors with efficiency class IE3 |
| Utilization category | AC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching |
| Voltage type | DC |
| Frame size | FS1 |
| Arcing time | 10 ms |
| Drop-out voltage | At least smoothed two-phase bridge rectifier or three-phase rectifier; 0.6 - 0.15 x UC, DC operated |
| Duty factor | 100 % |
| Pick-up voltage | 0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts); 0.8 - 1.1 V DC x Uc; 0.7 - 1.3 V DC x Uc (without auxiliary contact module and at ambient air temperature + 40 °C) |
| Power consumption (pick-up) at DC | 4.5 W |
| Power consumption (sealing) at DC | 4.5 W |
| Rated control supply voltage (Us) at DC - max | 24 V |
| Rated control supply voltage (Us) at DC - min | 24 V |
| Switching time (DC operated, make contacts, closing delay) - max | 31 ms |
| Switching time (DC operated, make contacts, opening delay) - max | 12 ms |
| Assigned motor power at 115/120 V, 60 Hz |
| 1-phase | 1 HP |
| Assigned motor power at 200/208 V, 60 Hz |
| 3-phase | 3 HP |
| Assigned motor power at 230/240 V, 60 Hz |
| 1-phase | 2 HP |
| Assigned motor power at 230/240 V, 60 Hz |
| Assigned motor power at 460/480 V, 60 Hz |
| 3-phase | 10 HP |
| Assigned motor power at 575/600 V, 60 Hz |
| Safe isolation | 400 V AC, Between the contacts, According to EN 61140; 400 V AC, Between coil and contacts, According to EN 61140 |
| Short-circuit current rating (basic rating) | 5 kA, 45 A max. fuse, SCCR (UL/CSA); 5 kA, 45 A max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 480 V) | 100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 600 V) | 100 kA, 45 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA) |
| Short-circuit protection rating (type 1 coordination) at 400 V | 35 A gG/gL |
| Short-circuit protection rating (type 1 coordination) at 690 V | 25 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 400 V | 20 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 690 V | 20 A gG/gL |
| Special purpose rating of definite purpose rating | 12 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 72 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
| Special purpose rating of elevator control | 2 HP, 240 V 60 Hz 3-ph, (UL/CSA); 7.5 HP, 480 V 60 Hz 3-ph, (UL/CSA); 11 A, 480 V 60 Hz 3-ph, (UL/CSA); 2 HP, 200 V 60 Hz 3-ph, (UL/CSA); 6.8 A, 240 V 60 Hz 3-ph, (UL/CSA); 7.5 HP, 600 V 60 Hz 3-ph, (UL/CSA); 9 A, 600 V 60 Hz 3-ph, (UL/CSA); 7.8 A, 200 V 60 Hz 3-ph, (UL/CSA) |
| Special purpose rating of refrigeration control (CSA only) | 60 A, LRA 480 V 60 Hz 3phase; (CSA); 10 A, FLA 480 V 60 Hz 3phase; (CSA); 60 A, LRA 600 V 60 Hz 3phase; (CSA); 10 A, FLA 600 V 60 Hz 3phase; (CSA) |
| Special purpose rating of resistance air heating | 20 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 20 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of tungsten incandescent lamps | 14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of ballast electrical discharge lamps | 20 A (480V 60Hz 3phase, 277V 60Hz 1phase); 20 A (600V 60Hz 3phase, 347V 60Hz 1phase) |
| Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA); 10 A, 600 V AC, (UL/CSA) |
| Switching capacity (auxiliary contacts, pilot duty) | A600, AC operated (UL/CSA); P300, DC operated (UL/CSA) |
| Switching capacity (main contacts, general use) | 20 A, Maximum motor rating (UL/CSA) |
| Screw size | M3.5, Terminal screw |
| Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver |
| Stripping length (control circuit cable) | 10 mm |
| Stripping length (main cable) | 10 mm |
| Terminal capacity (solid) | 2 x (0.75 - 2.5) mm²; 1 x (0.75 - 4) mm² |
| Tightening torque | 1.2 Nm, Screw terminals |
| Terminal capacity (flexible with ferrule) | 1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid/stranded AWG) | Single 18 - 10, double 18 - 14 |