cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor 7A AC-3 24V DC (DILM7-10(24VDC))

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM7-10(24VDC)  ·  HS 8536.90
Contactor 7A AC-3 24V DC (DILM7-10(24VDC))

Eaton DILM7-10(24VDC) DILM7 - Contactor 24 VDC incl. 1NO.

Technical Specifications

Manufacturer part number (MPN)DILM7-10(24VDC)
EAN / GTIN4015082765651
HS code8536.90
Sales unitpcs
Eaton catalogue number276565
Depth75 mm
Height68 mm
Width45 mm
Weight0.296 kg
CertificationsCSA; CSA-C22.2 No. 60947-4-1-14; UL File No.: E29096; CE; IEC/EN 60947; VDE 0660; UL Category Control No.: NLDX; CSA Class No.: 2411-03
3211-04; UL; CSA File No.012528; IEC/EN 60947-4-1; UL 60947-4-1
Catalog NotesContacts according to EN 50012
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DTIn conjunction with DIL-SWD SmartWire DT contactor module; Yes
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)1
Number of contacts (normally open contacts)1
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)45 A
Conventional thermal current Ith (3-pole, enclosed)18 A
Conventional thermal current Ith at 55°C (3-pole, open)21 A
Conventional thermal current Ith at 60°C (3-pole, open)20 A
Conventional thermal current Ith of main contacts (1-pole, open)50 A
Equipment heat dissipation, current-dependent Pvid0.3 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid0.1 W
Rated operational current for specified heat dissipation (In)7 A
Static heat dissipation, non-current-dependent Pvs3 W
Rated breaking capacity at 220/230 V70 A
Rated breaking capacity at 380/400 V70 A
Rated breaking capacity at 500 V50 A
Rated breaking capacity at 660/690 V40 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)112 A
Rated operational current (Ie) at AC-1, 380 V, 400 V
415 V22 A
Rated operational current (Ie) at AC-3, 220 V, 230 V
240 V7 A
Rated operational current (Ie) at AC-3, 380 V, 400 V
415 V7 A
Rated operational current (Ie) at AC-3
440 V7 A
Rated operational current (Ie) at AC-3
500 V5 A
Rated operational current (Ie) at AC-3, 660 V
690 V4 A
Rated operational current (Ie) at AC-4, 220 V, 230 V
240 V5 A
Rated operational current (Ie) at AC-4
440 V5 A
Rated operational current (Ie) at AC-4
500 V4.5 A
Rated operational current (Ie) at AC-4, 660 V
Rated operational current (Ie) at DC-1
110 V20 A
Rated operational current (Ie) at DC-1
220 V15 A
Rated operational current (Ie) at DC-1
60 V20 A
Rated operational power at AC-3, 240 V
50 Hz2.2 kW
Rated operational power at AC-3, 380/400 V
50 Hz3 kW
Rated operational power at AC-3, 415 V
50 Hz4 kW
Rated operational power at AC-3, 440 V
50 Hz4.5 kW
Rated operational power at AC-3, 500 V
50 Hz3.5 kW
Rated operational power at AC-3, 690 V
Rated operational power at AC-4, 220/230 V
50 Hz1 kW
Rated operational power at AC-4, 240 V
50 Hz1.5 kW
Rated operational power at AC-4, 415 V
50 Hz2.3 kW
Rated operational power at AC-4, 440 V
50 Hz2.4 kW
Rated operational power at AC-4, 500 V
50 Hz2.5 kW
Rated operational power at AC-4, 660/690 V
50 Hz2.9 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withVaristor suppressor circuit
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP20
Lifespan, mechanical10,000,000 Operations (DC operated)
Operating frequency9000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole4.6 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeDC
Frame sizeFS1
Arcing time10 ms
Drop-out voltageAt least smoothed two-phase bridge rectifier or three-phase rectifier; 0.6 - 0.15 x UC, DC operated
Duty factor100 %
Pick-up voltage0.8 - 1.1 V DC x Uc; 0.7 - 1.3 V DC x Uc (without auxiliary contact module and at ambient air temperature + 40 °C); 0.85 - 1.1 V DC x Uc (only with auxiliary contact module with 3 or more N/C contacts)
Power consumption (pick-up) at DC3 W
Power consumption (sealing) at DC3 W
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Switching time (DC operated, make contacts, closing delay) - max31 ms
Switching time (DC operated, make contacts, opening delay) - max12 ms
Assigned motor power at 115/120 V, 60 Hz
1-phase0.25 HP
Assigned motor power at 200/208 V, 60 Hz
3-phase1.5 HP
Assigned motor power at 230/240 V, 60 Hz
1-phase1 HP
Assigned motor power at 230/240 V, 60 Hz
3-phase2 HP
Assigned motor power at 460/480 V, 60 Hz
3-phase3 HP
Assigned motor power at 575/600 V, 60 Hz
3-phase5 HP
Safe isolation400 V AC, Between coil and contacts, According to EN 61140; 400 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)5 kA, 25 A max. fuse, SCCR (UL/CSA); 5 kA, 25 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA); 65 kA, 16 A max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)100 kA, 20 A CLASS J max. fuse, SCCR (UL/CSA); 30 kA, 25 A CLASS RK5 max. fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V20 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V16 A gG/gL
Special purpose rating of definite purpose rating42 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 7 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control3.7 A, 200 V 60 Hz 3-ph, (UL/CSA); 1.5 HP, 240 V 60 Hz 3-ph, (UL/CSA); 3.4 A, 480 V 60 Hz 3-ph, (UL/CSA); 3 HP, 600 V 60 Hz 3-ph, (UL/CSA); 3.9 A, 600 V 60 Hz 3-ph, (UL/CSA); 2 HP, 480 V 60 Hz 3-ph, (UL/CSA); 0.75 HP, 200 V 60 Hz 3-ph, (UL/CSA); 6 A, 240 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)10 A, FLA 480 V 60 Hz 3phase; (CSA); 60 A, LRA 480 V 60 Hz 3phase; (CSA); 60 A, LRA 600 V 60 Hz 3phase; (CSA); 10 A, FLA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating12 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 12 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps14 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 14 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps12 A (600V 60Hz 3phase, 347V 60Hz 1phase); 12 A (480V 60Hz 3phase, 277V 60Hz 1phase)
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300, DC operated (UL/CSA); A600, AC operated (UL/CSA)
Switching capacity (main contacts, general use)20 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw
Screwdriver size2, Terminal screw, Pozidriv screwdriver; 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)2 x (0.75 - 2.5) mm²; 1 x (0.75 - 4) mm²
Tightening torque1.2 Nm, Screw terminals
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm²
Terminal capacity (solid/stranded AWG)Single 18 - 10, double 18 - 14

Properties

MOQ1

Cross-References