cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

STYRECONTACTOR, 4S AC-Coil (DILA-40(24VDC))

Eaton · Control & Automation · Relays & Timers · Ireland · eaton.com
Part Number
DILA-40(24VDC)  ·  HS 8536.90
STYRECONTACTOR, 4S AC-Coil (DILA-40(24VDC))

Eaton DILA-40(24VDC) DILA Control Contactor - Contactor 24 VDC including 4NO.

Technical Specifications

Manufacturer part number (MPN)DILA-40(24VDC)
EAN / GTIN4015082763442
HS code8536.90
Sales unitpcs
Eaton catalogue number276344
Depth75 mm
Height68 mm
Width45 mm
Weight0.296 kg
CertificationsUL Category Control No.: NKCR; VDE 0660; UL 508; CSA Class No.: 3211-03; UL File No.: E29184; CSA; UL; CSA-C22.2 No. 14-05; EN 60947-5-1; CE; IEC/EN 60947; IEC/EN 60947-4-1; CSA File No.: 012528
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Connection to SmartWire-DTIn conjunction with DIL-SWD SmartWire DT contactor module; Yes
Code number40E
Control circuit reliabilityλ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA); λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)0
Number of auxiliary contacts (normally open contacts)4
Number of contacts (normally closed contacts)0
Number of contacts (normally open contacts)4
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid1 W
Rated operational current for specified heat dissipation (In)15.5 A
Static heat dissipation, non-current-dependent Pvs3 W
Conventional thermal current Ith at 60°C (3-pole, open)16 A
Rated insulation voltage (Ui)690 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V4 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V4 A
Rated operational current (Ie) at AC-15, 500 V1.5 A
Rated operational voltage (Ue) at AC - max690 V
Safe isolation400 V AC, Between coil and auxiliary contacts, According to EN 61140; 400 V AC, Between auxiliary contacts, According to EN 61140
Short-circuit protection rating without welding10 A gG/gL, 500 V, Max. Fuse, Contacts
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA); P300, DC operated (UL/CSA)
FeaturesPositive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module
Fitted withSuppressor circuit; Positive operation contacts; Built-in suppressor circuit
ApplicationContactor relays
ConnectionScrew terminals
Degree of protectionIP20
Lifespan, mechanical20,000,000 Operations (DC operated)
Mounting methodDIN-rail/screw
Operating frequency9000 Operations/h
Overvoltage categoryIII
Pollution degree3
Product categoryDILA relays
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)6000 V AC
Shock resistance5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Voltage typeDC
Duty factor100 %
Pick-up voltage0.7 - 1.3 V DC x Uc (at 24 V: without auxiliary contact module and at ambient air temperature + 40 °C); 0.8 - 1.1 V DC x Uc
Power consumption (pick-up) at DC2.6 W
Power consumption (sealing) at DC2.6 W
Rated control supply voltage (Us) at DC - max24 V
Rated control supply voltage (Us) at DC - min24 V
Switching time (DC operated, make contacts, closing delay) - max31 ms
Switching time (DC operated, make contacts, opening delay) - max12 ms
Voltage toleranceSmoothed DC, three-phase bridge rectifiers or smoothed double-wave rectification
Screw sizeM3.5, Terminal screw
Screwdriver size2, Terminal screw, Pozidriv screwdriver; 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (main cable)10 mm
Terminal capacity (flexible with ferrule)2 x (0.75 - 2.5) mm², Screw terminals; 1 x (0.75 - 2.5) mm², Screw terminals
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Screw terminals; 1 x (0.75 - 4) mm², Screw terminals
Terminal capacity (solid/stranded AWG)18 - 14, Screw terminals
Tightening torque1.2 Nm, Screw terminals

Properties

MOQ1

Cross-References

Attached Documents