Contactor,DILA-22(42V50HZ,48V60HZ) (DILA-22(42V50HZ,48V60HZ)-PI)

Eaton · Control & Automation · Relays & Timers · Ireland · eaton.com
Part Number
DILA-22(42V50HZ,48V60HZ)-PI  ·  HS 8536.90
Contactor,DILA-22(42V50HZ,48V60HZ) (DILA-22(42V50HZ,48V60HZ)-PI)

Eaton DILA-22(42V50HZ,48V60HZ)-PI Contactor, 42 V 50 Hz, 48 V 60 Hz, 2 N/O, 2 NC, Push in terminals, AC drift.

Technical Specifications

Manufacturer part number (MPN)DILA-22(42V50HZ,48V60HZ)-PI
EAN / GTIN4015081973019
HS code8536.90
Sales unitpcs
Eaton catalogue number199217
Depth75 mm
Height68 mm
Width45 mm
Weight0.227 kg
CertificationsIEC/EN 60947; EN 60947-5-1; VDE 0660; CSA File No.: 012528; CSA Class No.: 3211-03; UL File No.: E29184; UL 508; CSA-C22.2 No. 14-05; CE marking; UL Category Control No.: NKCR; UL; CSA
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min25 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Connection to SmartWire-DTNo
Code number22E
Control circuit reliabilityλ < 5 x 10-7 (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA); λ < 5 x 1/10⁷ (1 failure at 2,000,000 operations for Uₑ = 24 V DC, Umin = 17 V, Imin = 5.4 mA)
Number of auxiliary contacts (change-over contacts)0
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)2
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Rated insulation voltage (Ui)690 V
Rated operational current (Ie) at AC-15, 220 V, 230 V, 240 V4 A
Rated operational current (Ie) at AC-15, 380 V, 400 V, 415 V4 A
Rated operational current (Ie) at AC-15, 500 V1.5 A
Rated operational voltage (Ue) at AC - max690 V
Safe isolation400 V AC, Between coil and auxiliary contacts, According to EN 61140; 400 V AC, Between auxiliary contacts, According to EN 61140
Short-circuit protection rating without welding10 A gG/gL, 500 V, Max. Fuse, Contacts
Switching capacity (auxiliary contacts, general use)15 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA); P300, DC operated (UL/CSA)
FeaturesPositive operating contacts to EN 60947-5-1 appendix L, including auxiliary contact module
Fitted withPositive operation contacts
ApplicationContactor relays
ConnectionPush in terminals
Degree of protectionIP20
Lifespan, mechanical20,000,000 Operations (AC operated)
Mounting methodDIN-rail/screw
Operating frequency9000 Operations/h
Overvoltage categoryIII
Pollution degree3
Product categoryDILA relays
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)6000 V AC
Shock resistance5 g, N/C auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 7 g, N/O auxiliary contact, Basic unit with auxiliary contact module, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Voltage typeAC
Duty factor100 %
Pick-up voltage0.8 - 1.1 V AC x Uc (voltage tolerance - single-voltage coil 50 Hz and dual-voltage coil 50 Hz, 60 Hz)
Power consumption, pick-up, 50 Hz24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Power consumption, pick-up, 60 Hz24 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Power consumption, sealing, 50 Hz3.4 VA, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz; 1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Power consumption, sealing, 60 Hz1.4 W, AC, Single-frequency coil 50 Hz and Dual-frequency coil 50/60 Hz
Rated control supply voltage (Us) at AC, 50 Hz - max42 V
Rated control supply voltage (Us) at AC, 50 Hz - min42 V
Rated control supply voltage (Us) at AC, 60 Hz - max48 V
Rated control supply voltage (Us) at AC, 60 Hz - min48 V
Switching time (AC operated, make contacts, closing delay) - max21 ms
Switching time (AC operated, make contacts, closing delay) - min15 ms
Switching time (AC operated, make contacts, opening delay) - max18 ms
Switching time (AC operated, make contacts, opening delay) - min9 ms
Screwdriver size3.0 x 0.5 mm, Terminal screw
Stripping length (main cable)10 mm
Terminal capacity (flexible with ferrule)2 x (0.5 - 1.5) mm²; 1 x (0.5 - 2.5) mm²
Terminal capacity (solid)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²
Terminal capacity (solid/stranded AWG)20 - 14
Terminal capacity (flexible)1 x (0.5 - 2.5) mm²; 2 x (0.5 - 2.5) mm²

Properties

MOQ1