cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor DILM32-32(RDC24)

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM32-32(RDC24)  ·  HS 8536.90
Contactor DILM32-32(RDC24)

Eaton DILM32-32(RDC24) Contactor, 400V 15 kW, 3 N/O, 2 NC, RDC 24: 24 - 27 V DC.

Technical Specifications

Manufacturer part number (MPN)DILM32-32(RDC24)
EAN / GTIN4015082773700
HS code8536.90
Sales unitpcs
Eaton catalogue number277370
Depth138 mm
Height85 mm
Width45 mm
Weight0.603 kg
CompliancesCE Marked
CertificationsIEC 60947-4-1; UL 508; EN 60947-4-1; CSA Std. C22.2 No. 14-05; VDE; CE; CSA File No.: 012528; UL Category Control No.: NLDX; CSA; VDE 0660; IEC/EN 60947-4-1; UL 60947-4-1; CSA Class No.: 2411-03
3211-04; CSA-C22.2 No. 60947-4-1-14; UL File No.E29096; IEC/EN 60947; UL
Catalog NotesContacts according to EN 50012
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)3
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)3
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)90 A
Conventional thermal current Ith (3-pole, enclosed)36 A
Conventional thermal current Ith at 55°C (3-pole, open)42 A
Conventional thermal current Ith at 60°C (3-pole, open)40 A
Conventional thermal current Ith of main contacts (1-pole, open)100 A
Equipment heat dissipation, current-dependent Pvid6.6 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid2.2 W
Rated operational current for specified heat dissipation (In)32 A
Static heat dissipation, non-current-dependent Pvs0.9 W
Rated breaking capacity at 220/230 V320 A
Rated breaking capacity at 380/400 V320 A
Rated breaking capacity at 500 V320 A
Rated breaking capacity at 660/690 V180 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)384 A
Rated operational current (Ie) at AC-1, 380 V, 400 V
415 V45 A
Rated operational current (Ie) at AC-3, 220 V, 230 V
240 V32 A
Rated operational current (Ie) at AC-3, 380 V, 400 V
415 V32 A
Rated operational current (Ie) at AC-3
440 V32 A
Rated operational current (Ie) at AC-3
500 V32 A
Rated operational current (Ie) at AC-3, 660 V
690 V18 A
Rated operational current (Ie) at AC-4, 220 V, 230 V
240 V15 A
Rated operational current (Ie) at AC-4
440 V15 A
Rated operational current (Ie) at AC-4
500 V15 A
Rated operational current (Ie) at AC-4, 660 V
690 V12 A
Rated operational current (Ie) at DC-1
110 V40 A
Rated operational current (Ie) at DC-1
220 V40 A
Rated operational current (Ie) at DC-1
60 V40 A
Rated operational power at AC-3, 240 V
50 Hz11 kW
Rated operational power at AC-3, 380/400 V
50 Hz15 kW
Rated operational power at AC-3, 415 V
50 Hz19 kW
Rated operational power at AC-3, 440 V
50 Hz20 kW
Rated operational power at AC-3, 500 V
50 Hz23 kW
Rated operational power at AC-3, 690 V
50 Hz17 kW
Rated operational power at AC-4, 220/230 V
50 Hz4 kW
Rated operational power at AC-4, 240 V
50 Hz4.5 kW
Rated operational power at AC-4, 415 V
50 Hz7.5 kW
Rated operational power at AC-4, 440 V
50 Hz8 kW
Rated operational power at AC-4, 500 V
50 Hz9 kW
Rated operational power at AC-4, 660/690 V
50 Hz10 kW
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withMirror contact; Suppressor circuit in actuating electronics
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical10,000,000 Operations (DC operated); 7,000,000 Operations (Coil 50/60 Hz)
Operating frequency5000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole2.7 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-3: Normal AC induction motors: starting, switch off during running; AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeDC
Arcing time10 ms
Drop-out voltageAt least smoothed two-phase bridge rectifier or three-phase rectifier; 0.6 - 0.15 x UC, DC operated
Duty factor100 %
Pick-up voltage24 - 27 V DC (RDC 24); 0.7 - 1.2 V DC x Uc
Power consumption (pick-up) at DC12 W
Power consumption (sealing) at DC0.9 W
Rated control supply voltage (Us) at DC - max27 V
Rated control supply voltage (Us) at DC - min24 V
Switching time (DC operated, make contacts, closing delay) - max47 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
Assigned motor power at 115/120 V, 60 Hz
1-phase2 HP
Assigned motor power at 200/208 V, 60 Hz
3-phase10 HP
Assigned motor power at 230/240 V, 60 Hz
1-phase5 HP
Assigned motor power at 230/240 V, 60 Hz
Assigned motor power at 460/480 V, 60 Hz
3-phase20 HP
Assigned motor power at 575/600 V, 60 Hz
3-phase25 HP
Safe isolation440 V AC, Between coil and contacts, According to EN 61140; 440 V AC, Between the contacts, According to EN 61140
Short-circuit current rating (basic rating)125 A, max. Fuse, SCCR (UL/CSA); 5 kA, SCCR (UL/CSA); 125 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)10/100 kA, Fuse, SCCR (UL/CSA); 125/70 A, Class J, max. Fuse, SCCR (UL/CSA); 10/65 kA, CB, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)10/100 kA, Fuse, SCCR (UL/CSA); 10/22 kA, CB, SCCR (UL/CSA); 125/125 A, Class J, max. Fuse, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V125 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V63 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V35 A gG/gL
Special purpose rating of definite purpose rating32 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 192 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control27 A, 480 V 60 Hz 3-ph, (UL/CSA); 20 HP, 600 V 60 Hz 3-ph, (UL/CSA); 20 HP, 480 V 60 Hz 3-ph, (UL/CSA); 7.5 HP, 240 V 60 Hz 3-ph, (UL/CSA); 25.3 A, 200 V 60 Hz 3-ph, (UL/CSA); 22 A, 240 V 60 Hz 3-ph, (UL/CSA); 7.5 HP, 200 V 60 Hz 3-ph, (UL/CSA); 22 A, 600 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)30 A, FLA 600 V 60 Hz 3phase; (CSA); 240 A, LRA 480 V 60 Hz 3phase; (CSA); 180 A, LRA 600 V 60 Hz 3phase; (CSA); 40 A, FLA 480 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps40 A (480V 60Hz 3phase, 277V 60Hz 1phase); 40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Switching capacity (auxiliary contacts, general use)1 A, 250 V DC, (UL/CSA); 10 A, 600 V AC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)P300, DC operated (UL/CSA); A600, AC operated (UL/CSA)
Switching capacity (main contacts, general use)40 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw, Control circuit cables; M5, Terminal screw, Main cables
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 10) mm², Main cables; 1 x (0.75 - 16) mm², Main cables
Terminal capacity (stranded)1 x 16 mm², Main cables
Tightening torque3.2 Nm, Screw terminals, Main cables; 1.2 Nm, Screw terminals, Control circuit cables
Terminal capacity (flexible with ferrule)1 x (0.75 - 16) mm², Main cables; 2 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 10) mm², Main cables; 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)Single 18 - 6, double 18 - 8, Main cables; 18 - 14, Control circuit cables

Properties

MOQ1

Cross-References

Attached Documents