cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor DILM25-32(RDC24)

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
DILM25-32(RDC24)  ·  HS 8536.90
Contactor DILM25-32(RDC24)

Eaton DILM25-32(RDC24) Contactor, 400V 11 kW, 3 N/O, 2 NC, RDC 24: 24 - 27 V DC.

Technical Specifications

Manufacturer part number (MPN)DILM25-32(RDC24)
EAN / GTIN4015082772420
HS code8536.90
Sales unitpcs
Eaton catalogue number277242
Depth138 mm
Height85 mm
Width45 mm
Weight0.613 kg
CertificationsCSA File No.: 012528; UL Category Control No.: NLDX; CSA-C22.2 No. 60947-4-1-14; CSA Class No.: 2411-03
3211-04; UL; IEC/EN 60947; IEC/EN 60947-4-1; UL File No.E29096; CSA; UL 60947-4-1; CE; VDE 0660
Catalog NotesContacts according to EN 50012
AltitudeMax. 2000 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-25 °C
Ambient operating temperature (enclosed) - max40 °C
Ambient operating temperature (enclosed) - min-25 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, constant, to IEC 60068-2-78; Damp heat, cyclic, to IEC 60068-2-30
Number of main contacts (normally open contact)3
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)3
Number of contacts (normally closed contacts)2
Number of contacts (normally open contacts)3
Number of contacts (normally closed) as main contact0
Conventional thermal current Ith (1-pole, enclosed)90 A
Conventional thermal current Ith (3-pole, enclosed)36 A
Conventional thermal current Ith at 55°C (3-pole, open)42 A
Conventional thermal current Ith at 60°C (3-pole, open)40 A
Conventional thermal current Ith of main contacts (1-pole, open)100 A
Equipment heat dissipation, current-dependent Pvid4.2 W
Heat dissipation capacity Pdiss0 W
Heat dissipation per pole, current-dependent Pvid1.4 W
Rated operational current for specified heat dissipation (In)25 A
Static heat dissipation, non-current-dependent Pvs0.9 W
Rated breaking capacity at 220/230 V250 A
Rated breaking capacity at 380/400 V250 A
Rated breaking capacity at 500 V250 A
Rated breaking capacity at 660/690 V150 A
Rated insulation voltage (Ui)690 V
Rated making capacity up to 690 V (cos phi to IEC/EN 60947)350 A
Rated operational current (Ie) at AC-1, 380 V, 400 V
415 V45 A
Rated operational current (Ie) at AC-3, 220 V, 230 V
240 V25 A
Rated operational current (Ie) at AC-3, 380 V, 400 V
415 V25 A
Rated operational current (Ie) at AC-3
440 V25 A
Rated operational current (Ie) at AC-3
500 V25 A
Rated operational current (Ie) at AC-3, 660 V
690 V15 A
Rated operational current (Ie) at AC-4, 220 V, 230 V
240 V13 A
Rated operational current (Ie) at AC-4
440 V13 A
Rated operational current (Ie) at AC-4
500 V13 A
Rated operational current (Ie) at AC-4, 660 V
690 V10 A
Rated operational current (Ie) at DC-1
110 V40 A
Rated operational current (Ie) at DC-1
220 V40 A
Rated operational current (Ie) at DC-1
60 V40 A
Rated operational power at AC-3, 240 V
50 Hz8.5 kW
Rated operational power at AC-3, 380/400 V
50 Hz11 kW
Rated operational power at AC-3, 415 V
50 Hz14.5 kW
Rated operational power at AC-3, 440 V
50 Hz15.5 kW
Rated operational power at AC-3, 500 V
50 Hz17.5 kW
Rated operational power at AC-3, 690 V
50 Hz14 kW
Rated operational power at AC-4, 220/230 V
50 Hz3.5 kW
Rated operational power at AC-4, 240 V
50 Hz4 kW
Rated operational power at AC-4, 415 V
50 Hz6.5 kW
Rated operational power at AC-4, 440 V
50 Hz7 kW
Rated operational power at AC-4, 500 V
50 Hz8 kW
Rated operational power at AC-4, 660/690 V
Rated operational voltage (Ue) at AC - max690 V
Emitted interferenceAccording to EN 60947-1
Interference immunityAccording to EN 60947-1
Fitted withSuppressor circuit in actuating electronics; Mirror contact
Number of polesThree-pole
ApplicationContactors for Motors
ConnectionScrew terminals
Degree of protectionIP00
Lifespan, mechanical7,000,000 Operations (Coil 50/60 Hz); 10,000,000 Operations (DC operated)
Operating frequency5000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
ProtectionFinger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274)
Rated impulse withstand voltage (Uimp)8000 V AC
Resistance per pole2.7 mΩ
Suitable forAlso motors with efficiency class IE3
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-3: Normal AC induction motors: starting, switch off during running; AC-4: Normal AC induction motors: starting, plugging, reversing, inching
Voltage typeDC
Arcing time10 ms
Drop-out voltage0.6 - 0.15 x UC, DC operated; At least smoothed two-phase bridge rectifier or three-phase rectifier
Duty factor100 %
Pick-up voltage0.7 - 1.2 V DC x Uc; 24 - 27 V DC (RDC 24)
Power consumption (pick-up) at DC12 W
Power consumption (sealing) at DC0.9 W
Rated control supply voltage (Us) at DC - max27 V
Rated control supply voltage (Us) at DC - min24 V
Switching time (DC operated, make contacts, closing delay) - max47 ms
Switching time (DC operated, make contacts, opening delay) - max30 ms
Assigned motor power at 115/120 V, 60 Hz
1-phase2 HP
Assigned motor power at 200/208 V, 60 Hz
3-phase7.5 HP
Assigned motor power at 230/240 V, 60 Hz
1-phase5 HP
Assigned motor power at 230/240 V, 60 Hz
3-phase10 HP
Assigned motor power at 460/480 V, 60 Hz
3-phase15 HP
Assigned motor power at 575/600 V, 60 Hz
3-phase20 HP
Safe isolation440 V AC, Between the contacts, According to EN 61140; 440 V AC, Between coil and contacts, According to EN 61140
Short-circuit current rating (basic rating)125 A, max. Fuse, SCCR (UL/CSA); 5 kA, SCCR (UL/CSA); 125 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 480 V)10/65 kA, CB, SCCR (UL/CSA); 10/100 kA, Fuse, SCCR (UL/CSA); 125/70 A, Class J, max. Fuse, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA)
Short-circuit current rating (high fault at 600 V)10/22 kA, CB, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA); 10/100 kA, Fuse, SCCR (UL/CSA); 125/100 A, Class J, max. Fuse, SCCR (UL/CSA)
Short-circuit protection rating (type 1 coordination) at 400 V100 A gG/gL
Short-circuit protection rating (type 1 coordination) at 690 V50 A gG/gL
Short-circuit protection rating (type 2 coordination) at 400 V35 A gG/gL
Short-circuit protection rating (type 2 coordination) at 690 V35 A gG/gL
Special purpose rating of definite purpose rating25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 150 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA)
Special purpose rating of elevator control14 A, 480 V 60 Hz 3-ph, (UL/CSA); 3 HP, 200 V 60 Hz 3-ph, (UL/CSA); 11 A, 200 V 60 Hz 3-ph, (UL/CSA); 15 HP, 600 V 60 Hz 3-ph, (UL/CSA); 15.2 A, 240 V 60 Hz 3-ph, (UL/CSA); 17 A, 600 V 60 Hz 3-ph, (UL/CSA); 5 HP, 240 V 60 Hz 3-ph, (UL/CSA); 10 HP, 480 V 60 Hz 3-ph, (UL/CSA)
Special purpose rating of refrigeration control (CSA only)40 A, FLA 480 V 60 Hz 3phase; (CSA); 30 A, FLA 600 V 60 Hz 3phase; (CSA); 240 A, LRA 480 V 60 Hz 3phase; (CSA); 180 A, LRA 600 V 60 Hz 3phase; (CSA)
Special purpose rating of resistance air heating40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA); 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of tungsten incandescent lamps40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA)
Special purpose rating of ballast electrical discharge lamps40 A (480V 60Hz 3phase, 277V 60Hz 1phase); 40 A (600V 60Hz 3phase, 347V 60Hz 1phase)
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA); P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)40 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw, Control circuit cables; M5, Terminal screw, Main cables
Screwdriver size2, Terminal screw, Pozidriv screwdriver; 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver
Stripping length (control circuit cable)10 mm
Stripping length (main cable)10 mm
Terminal capacity (solid)2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 2.5) mm², Control circuit cables; 2 x (0.75 - 10) mm², Main cables; 1 x (0.75 - 16) mm², Main cables
Terminal capacity (stranded)1 x 16 mm², Main cables
Tightening torque1.2 Nm, Screw terminals, Control circuit cables; 3.2 Nm, Screw terminals, Main cables
Terminal capacity (flexible with ferrule)2 x (0.75 - 10) mm², Main cables; 2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 16) mm², Main cables; 1 x (0.75 - 2.5) mm², Control circuit cables
Terminal capacity (solid/stranded AWG)18 - 14, Control circuit cables; Single 18 - 6, double 18 - 8, Main cables

Properties

MOQ1

Cross-References

Attached Documents