| Manufacturer part number (MPN) | DILMP45-01(RDC24) |
| EAN / GTIN | 4015081170432 |
| HS code | 8536.90 |
| Sales unit | pcs |
| Eaton catalogue number | 118916 |
| Depth | 97 mm |
| Height | 85 mm |
| Width | 58 mm |
| Weight | 0.596 kg |
| Certifications | CSA Class No.: 2411-03 |
| 3211-04; IEC/EN 60947-4-1; UL File No. | E29096; CSA File No.: 012528; CE; IEC/EN 60947; VDE 0660; CSA; UL Category Control No.: NLDX; CSA-C22.2 No. 60947-4-1-14; UL; UL 60947-4-1 |
| Catalog Notes | Also tested according to AC-3e. |
| Shock resistance | 5 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 7 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms |
| Altitude | Max. 2000 m |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 80 °C |
| Ambient operating temperature - min | -25 °C |
| Ambient operating temperature (enclosed) - max | 40 °C |
| Ambient operating temperature (enclosed) - min | -25 °C |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-3 |
| Connection to SmartWire-DT | In conjunction with DIL-SWD SmartWire DT contactor module; Yes |
| Number of main contacts (normally open contact) | 4 |
| Number of auxiliary contacts (normally closed contacts) | 1 |
| Number of auxiliary contacts (normally open contacts) | 0 |
| Number of contacts (normally closed contacts) | 1 |
| Number of contacts (normally closed) as main contact | 0 |
| Conventional thermal current Ith (1-pole, enclosed) | 105 A |
| Conventional thermal current Ith (3-pole, enclosed) | 36 A |
| Conventional thermal current Ith at 55°C (3-pole, open) | 40 A |
| Conventional thermal current Ith at 60°C (3-pole, open) | 39 A |
| Conventional thermal current Ith of main contacts (1-pole, open) | 117 A |
| Equipment heat dissipation, current-dependent Pvid | 13.2 W |
| Heat dissipation capacity Pdiss | 0 W |
| Heat dissipation per pole, current-dependent Pvid | 4.4 W |
| Rated operational current for specified heat dissipation (In) | 45 A |
| Static heat dissipation, non-current-dependent Pvs | 0.9 W |
| Rated breaking capacity at 220/230 V | 250 A |
| Rated breaking capacity at 380/400 V | 250 A |
| Rated breaking capacity at 500 V | 250 A |
| Rated breaking capacity at 660/690 V | 144 A |
| Rated insulation voltage (Ui) | 690 V |
| Rated making capacity up to 690 V (cos phi to IEC/EN 60947) | 350 A |
| Rated operational current (Ie) at AC-1, 380 V, 400 V |
| 415 V | 45 A |
| Rated operational current (Ie) at AC-3, 220 V, 230 V |
| 240 V | 25 A |
| Rated operational current (Ie) at AC-3, 380 V, 400 V |
| 415 V | 25 A |
| Rated operational current (Ie) at AC-3 |
| 440 V | 25 A |
| Rated operational current (Ie) at AC-3 |
| 500 V | 25 A |
| Rated operational current (Ie) at AC-3, 660 V |
| 690 V | 15 A |
| Rated operational current (Ie) at DC-1 |
| 110 V | 45 A |
| Rated operational current (Ie) at DC-1 |
| 220 V | 45 A |
| Rated operational current (Ie) at DC-1 |
| 60 V | 45 A |
| Rated operational power at AC-1, 220/230 V |
| 50 Hz | 16 kW |
| Rated operational power at AC-1, 240 V |
| 50 Hz | 18 kW |
| Rated operational power at AC-1, 380/400 V |
| 50 Hz | 28 kW |
| Rated operational power at AC-1, 415 V |
| 50 Hz | 31 kW |
| Rated operational power at AC-1, 440 V |
| 50 Hz | 33 kW |
| Rated operational power at AC-1, 500 V |
| 50 Hz | 37 kW |
| Rated operational power at AC-1, 690 V |
| 50 Hz | 49 kW |
| Rated operational power at AC-3, 240 V |
| 50 Hz | 8.5 kW |
| Rated operational power at AC-3, 380/400 V |
| 50 Hz | 11 kW |
| Rated operational power at AC-3, 415 V |
| 50 Hz | 14.5 kW |
| Rated operational power at AC-3, 440 V |
| 50 Hz | 15.5 kW |
| Rated operational power at AC-3, 500 V |
| 50 Hz | 17.5 kW |
| Rated operational power at AC-3, 690 V |
| 50 Hz | 14 kW |
| Rated operational voltage (Ue) at AC - max | 690 V |
| Interference immunity | According to EN 60947-1 |
| Fitted with | Mirror contact; Suppressor circuit in actuating electronics |
| Number of poles | Four-pole |
| Application | Contactors for 4 pole electric consumers |
| Connection | Screw terminals |
| Degree of protection | IP00 |
| Lifespan, mechanical | 10,000,000 Operations (AC operated); 10,000,000 Operations (DC operated) |
| Operating frequency | 5000 mechanical Operations/h (DC operated); 5000 mechanical Operations/h (AC operated) |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | Contactors |
| Protection | Finger and back-of-hand proof, Protection against direct contact when actuated from front (EN 50274) |
| Rated impulse withstand voltage (Uimp) | 8000 V AC |
| Residual current | 1 mA (with actuation of A1 - A2 by the electronics with "0" signal) |
| Resistance per pole | 2.7 mΩ |
| Utilization category | AC-1: Non-inductive or slightly inductive loads, resistance furnaces; AC-3: Normal AC induction motors: starting, switch off during running |
| Voltage type | DC |
| Arcing time | 10 ms |
| Drop-out voltage | 0.2 - 0.6 x UC, DC operated |
| Duty factor | 100 % |
| Pick-up voltage | 0.7 - 1.2 V DC x Uc; 0.85 - 1.1 V AC/DC x Us |
| Power consumption (pick-up) at DC | 12 W |
| Power consumption (sealing) at DC | 0.9 W |
| Rated control supply voltage (Us) at DC - max | 27 V |
| Rated control supply voltage (Us) at DC - min | 24 V |
| Switching time (DC operated, make contacts, closing delay) - max | 47 ms |
| Switching time (DC operated, make contacts, opening delay) - max | 30 ms |
| Assigned motor power at 115/120 V, 60 Hz |
| 1-phase | 2 HP |
| Assigned motor power at 200/208 V, 60 Hz |
| 3-phase | 7.5 HP |
| Assigned motor power at 230/240 V, 60 Hz |
| 1-phase | 5 HP |
| Assigned motor power at 230/240 V, 60 Hz |
| 3-phase | 10 HP |
| Assigned motor power at 460/480 V, 60 Hz |
| 3-phase | 15 HP |
| Assigned motor power at 575/600 V, 60 Hz |
| 3-phase | 20 HP |
| Safe isolation | 440 V AC, Between the contacts, According to EN 61140; 440 V AC, Between coil and contacts, According to EN 61140 |
| Short-circuit current rating (basic rating) | 5 kA, SCCR (UL/CSA); 125 A, max. Fuse, SCCR (UL/CSA); 125 A, max. CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 480 V) | 50/32 A, max. CB, SCCR (UL/CSA); 10/100 kA, Fuse, SCCR (UL/CSA); 125/70 A, Class J, max. Fuse, SCCR (UL/CSA); 10/65 kA, CB, SCCR (UL/CSA) |
| Short-circuit current rating (high fault at 600 V) | 10/100 kA, Fuse, SCCR (UL/CSA); 125/100 A, Class J, max. Fuse, SCCR (UL/CSA); 10/22 kA, CB, SCCR (UL/CSA); 50/32 A, max. CB, SCCR (UL/CSA) |
| Short-circuit protection rating (type 1 coordination) at 400 V | 100 A gG/gL |
| Short-circuit protection rating (type 1 coordination) at 690 V | 50 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 400 V | 35 A gG/gL |
| Short-circuit protection rating (type 2 coordination) at 690 V | 35 A gG/gL |
| Special purpose rating of definite purpose rating | 25 A, FLA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA); 150 A, LRA 480 V 60 Hz 3-ph, 100,000 cycles acc. to UL 1995, (UL/CSA) |
| Special purpose rating of elevator control | 15 HP, 600 V 60 Hz 3-ph, (UL/CSA); 3 HP, 200 V 60 Hz 3-ph, (UL/CSA); 17 A, 600 V 60 Hz 3-ph, (UL/CSA); 5 HP, 240 V 60 Hz 3-ph, (UL/CSA); 10 HP, 480 V 60 Hz 3-ph, (UL/CSA); 11 A, 200 V 60 Hz 3-ph, (UL/CSA); 15.2 A, 240 V 60 Hz 3-ph, (UL/CSA); 14 A, 480 V 60 Hz 3-ph, (UL/CSA) |
| Special purpose rating of refrigeration control (CSA only) | 240 A, LRA 480 V 60 Hz 3phase; (CSA); 30 A, FLA 600 V 60 Hz 3phase; (CSA); 40 A, FLA 480 V 60 Hz 3phase; (CSA); 180 A, LRA 600 V 60 Hz 3phase; (CSA) |
| Special purpose rating of resistance air heating | 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of tungsten incandescent lamps | 40 A, 480 V 60 Hz 3phase, 277 V 60 Hz 1phase, (UL/CSA); 40 A, 600 V 60 Hz 3phase, 347 V 60 Hz 1phase, (UL/CSA) |
| Special purpose rating of ballast electrical discharge lamps | 40 A (480V 60Hz 3phase, 277V 60Hz 1phase); 40 A (600V 60Hz 3phase, 347V 60Hz 1phase) |
| Switching capacity (auxiliary contacts, general use) | 1 A, 250 V DC, (UL/CSA); 10 A, 600 V AC, (UL/CSA) |
| Switching capacity (auxiliary contacts, pilot duty) | P300, DC operated (UL/CSA); A600, AC operated (UL/CSA) |
| Switching capacity (main contacts, general use) | 40 A, Maximum motor rating (UL/CSA) |
| Screw size | M3.5, Terminal screw, Control circuit cables; M5, Terminal screw, Main cables |
| Screwdriver size | 0.8 x 5.5/1 x 6 mm, Terminal screw, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver |
| Stripping length (control circuit cable) | 10 mm |
| Stripping length (main cable) | 10 mm |
| Terminal capacity (flexible) | 1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm² |
| Terminal capacity (solid) | 1 x (0.75 - 16) mm², Main cables; 2 x (0.75 - 2.5) mm², Control circuit cables; 1 x (0.75 - 4) mm², Control circuit cables; 2 x (0.75 - 10) mm², Main cables; 1 x (0.75 - 2.5) mm² |
| Terminal capacity (stranded) | 1 x 16 mm², Main cables |
| Tightening torque | 1.2 Nm, Screw terminals, Control circuit cables; 3 Nm, Screw terminals, Main cables |
| Terminal capacity (flexible with ferrule) | 1 x (0.75 - 1.5) mm²; 2 x (0.75 - 1.5) mm² |
| Terminal capacity (solid/stranded AWG) | 18 - 6, Main cables; 18 - 14, Control circuit cables |