| Manufacturer part number (MPN) | DE1-34016FN-N20N |
| EAN / GTIN | 4015081708024 |
| Sales unit | pcs |
| Eaton catalogue number | 174340 |
| Depth | 169 mm |
| Height | 230 mm |
| Width | 90 mm |
| Weight | 1.6 kg |
| Catalog Notes | Overload cycle for 60 s every 600 s |
| Apparent power at 400 V | 11.09 kVA |
| Apparent power at 480 V | 13.3 kVA |
| Braking torque | Max. 30 % MN, Standard - Main circuit; Adjustable to 100 %, DC - Main circuit |
| Altitude | Above 1000 m with 1 % derating per 100 m; Max. 2000 m |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 70 °C |
| Ambient operating temperature - min | -10 °C |
| Ambient operating temperature at 150% overload - max | 50 °C |
| Ambient operating temperature at 150% overload - min | -10 °C |
| Ambient operating temperature details | Derating between 50 °C and 60 °C: None if fPWM ≤ 14 kHz up to a max. of 50 °C None if fPWM ≤ 16 kHz up to a max. of 46 °C None if Iₑ ≤ 10.6 A and fPWM ≤ 20 kHz None if Iₑ ≤ 14.9 A and fPWM ≤ 10 kHz |
| Ambient storage temperature - min | -40 °C |
| Climatic proofing | < 95 average relative humidity (RH), no condensation, no corrosion |
| Number of inputs (analog) | 1 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA) |
| Number of inputs (digital) | 4 (parameterizable, 10 - 30 V DC) |
| Number of outputs (analog) | 0 |
| Number of outputs (digital) | 0 |
| Number of relay outputs | 1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1)) |
| Equipment heat dissipation, current-dependent Pvid | 240 W |
| Rated operational current for specified heat dissipation (In) | 16 A |
| Features | Parameterization: drivesConnect; Parameterization: drivesConnect mobile (App); Parameterization: Fieldbus; Parameterization: Keypad |
| Fitted with | PC connection; Radio interference suppression filter |
| Cable length | C2 ≤ 10 m, Radio interference level, maximum motor cable length; C3 ≤ 25 m, Radio interference level, maximum motor cable length |
| Communication interface | Modbus RTU, built in; OP-Bus (RS485), built in |
| Connection to SmartWire-DT | In conjunction with DX-NET-SWD3 SmartWire DT module; Yes |
| Degree of protection | IP20; NEMA Other |
| Electromagnetic compatibility | 1st and 2nd environments (according to EN 61800-3) |
| Frame size | FS2 |
| Product category | Variable speed starter |
| Protection | Finger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4) |
| Protocol | MODBUS; EtherNet/IP; Other bus systems |
| Radio interference class | C2 |
| C3 | depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.; Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments |
| Shock resistance | 15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms |
| Suitable for | Branch circuits, (UL/CSA) |
| Vibration | Resistance: According to EN 61800-5-1 |
| Heat dissipation at current/speed | 116 W at 50% current and 0% speed; 121 W at 50% current and 50% speed; 126 W at 50% current and 90% speed; 180 W at 100% current and 0% speed; 198 W at 100% current and 50% speed; 216 W at 100% current and 90% speed; 78 W at 25% current and 0% speed; 86 W at 25% current and 50% speed |
| Input current ILN at 150% overload | 16.5 A |
| Leakage current at ground IPE - max | < 3.5 mA (AC-operated); < 10 mA (DC-operated) |
| Mains switch-on frequency | Maximum of one time every 30 seconds |
| Mains voltage - max | 480 V |
| Mains voltage - min | 380 V |
| Operating mode | U/f control; Speed control with slip compensation |
| Output frequency - max | 300 Hz |
| Output voltage (U2) | 400 V AC, 3-phase; 480 V AC, 3-phase |
| Overload current IL at 150% overload | 24 A |
| Rated control supply voltage | 10 V DC (Us, max. 0.2 mA) |
| Rated frequency - max | 66 Hz |
| Rated frequency - min | 45 Hz |
| Rated operational current (Ie) | 16 A at 150% overload (at an operating frequency of 16 kHz and an ambient air temperature of +50 °C) |
| Rated operational power at 380/400 V, 50 Hz |
| 3-phase | 7.5 kW |
| Rated operational voltage | 400 V AC, 3-phase; 480 V AC, 3-phase |
| Resolution | 0.025 Hz (Frequency resolution, setpoint value) |
| Short-circuit protection rating | 25 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring |
| Starting current - max | 200 %, IH, max. starting current (High Overload), For 1.875 seconds every 600 seconds, Power section |
| Supply frequency | 50/60 Hz |
| Switching frequency | 16 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit |
| Voltage rating - max | 480 V |
| Assigned motor current IM at 400 V, 50 Hz |
| 150% overload | 15.2 A |
| Assigned motor current IM at 440 - 480 V, 60 Hz |
| 150% overload | 14 A |
| Assigned motor power at 460/480 V, 60 Hz |
| 3-phase | 10 HP |
| Power consumption | 240 W |
| With control element | No |
| Number of digital inputs | 4 |
| Number of analogue inputs | 1 |
| Supporting protocol for LON | No |
| Number of HW-interfaces RS-485 | 1 |
| With optical interface | No |
| Supporting protocol for TCP/IP | No |
| Supporting protocol for ASI | No |
| Supporting protocol for PROFIBUS | No |
| Supporting protocol for CAN | No |
| Supporting protocol for INTERBUS | No |
| Supporting protocol for KNX | No |
| Supporting protocol for Modbus | Yes |
| Supporting protocol for Data-Highway | No |
| Supporting protocol for DeviceNet | No |
| Supporting protocol for SUCONET | No |
| Supporting protocol for other bus systems | Yes |
| With PC connection | Yes |
| Supporting protocol for SERCOS | No |
| Supporting protocol for INTERBUS-Safety | No |
| Mains voltage | 380–480 V |
| Mains frequency | 50/60 Hz |
| 4-quadrant operation possible | No |
| Type of converter | U converter |
| Number of phases output | 3 |
| Number of phases input | 3 |
| Integrated breaking resistance | No |
| Application in industrial area permitted | Yes |
| Application in domestic- and commercial area permitted | Yes |
| Max. output frequency | 300 Hz |
| Max. output at linear load at rated output voltage | 0.5 kW |
| Max. output at quadratic load at rated output voltage | 0.5 kW |
| Relative symmetric net voltage tolerance | 10 % |
| Relative symmetric net frequency tolerance | 10 % |
| Supporting protocol for AS-Interface Safety at Work | No |
| Supporting protocol for DeviceNet Safety | No |
| Supporting protocol for EtherNet/IP | Yes |
| Supporting protocol for Foundation Fieldbus | No |
| Supporting protocol for PROFINET CBA | No |
| Supporting protocol for PROFINET IO | No |
| Supporting protocol for PROFIsafe | No |
| Supporting protocol for SafetyBUS p | No |
| Max. output voltage | 500 V |
| Nominal output current I2N | 7.5 A |
| Supporting protocol for BACnet | No |
| Country of origin | United Kingdom |