cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

DE1 3~/3~480V 8,5 A 4 kW/5HP (DE1-348D5FN-N20N)

Eaton · Drives & Controllers · Variable Frequency Drives · Ireland · eaton.com
Part Number
DE1-348D5FN-N20N  ·  HS 8504.40
DE1 3~/3~480V 8,5 A 4 kW/5HP (DE1-348D5FN-N20N)

Technical Specifications

Manufacturer part number (MPN)DE1-348D5FN-N20N
EAN / GTIN4015081708000
Sales unitpcs
Eaton catalogue number174338
Depth169 mm
Height230 mm
Width90 mm
Weight1.6 kg
Catalog NotesOverload cycle for 60 s every 600 s
Apparent power at 400 V5.89 kVA
Apparent power at 480 V7.07 kVA
Braking torqueMax. 30 % MN, Standard - Main circuit; Adjustable to 100 %, DC - Main circuit
AltitudeMax. 2000 m; Above 1000 m with 1 % derating per 100 m
Ambient operating temperature - max60 °C
Ambient storage temperature - max70 °C
Ambient operating temperature - min-10 °C
Ambient operating temperature at 150% overload - max60 °C
Ambient operating temperature at 150% overload - min-10 °C
Ambient storage temperature - min-40 °C
Climatic proofing< 95 average relative humidity (RH), no condensation, no corrosion
Number of inputs (analog)1 (parameterizable, 0 - 10 V DC, 0/4 - 20 mA)
Number of inputs (digital)4 (parameterizable, 10 - 30 V DC)
Number of outputs (analog)0
Number of outputs (digital)0
Number of relay outputs1 (parameterizable, N/O, 6 A (250 V, AC-1) / 5 A (30 V, DC-1))
Equipment heat dissipation, current-dependent Pvid120 W
Rated operational current for specified heat dissipation (In)8.5 A
FeaturesParameterization: drivesConnect; Parameterization: drivesConnect mobile (App); Parameterization: Fieldbus; Parameterization: Keypad
Fitted withRadio interference suppression filter; PC connection
Cable lengthC2 ≤ 10 m, Radio interference level, maximum motor cable length; C3 ≤ 25 m, Radio interference level, maximum motor cable length
Communication interfaceModbus RTU, built in; OP-Bus (RS485), built in
Connection to SmartWire-DTYes; In conjunction with DX-NET-SWD3 SmartWire DT module
Degree of protectionIP20; NEMA Other
Electromagnetic compatibility1st and 2nd environments (according to EN 61800-3)
Frame sizeFS2
Product categoryVariable speed starter
ProtectionFinger and back-of-hand proof, Protection against direct contact (BGV A3, VBG4)
ProtocolMODBUS; EtherNet/IP; Other bus systems
Radio interference classC2
C3depending on the motor cable length, the connected load, and ambient conditions. External radio interference suppression filters (optional) may be necessary.; Optional external radio interference suppression filter for longer motor cable lengths and for use in different EMC environments
Shock resistance15 g, Mechanical, According to IEC/EN 60068-2-27, 11 ms
Suitable forBranch circuits, (UL/CSA)
VibrationResistance: According to EN 61800-5-1
Heat dissipation at current/speed101 W at 100% current and 90% speed; 47 W at 25% current and 0% speed; 51 W at 25% current and 50% speed; 55 W at 50% current and 0% speed; 60 W at 50% current and 50% speed; 65 W at 50% current and 90% speed; 76 W at 100% current and 0% speed; 93 W at 100% current and 50% speed
Input current ILN at 150% overload10 A
Leakage current at ground IPE - max< 3.5 mA (AC-operated); < 10 mA (DC-operated)
Mains switch-on frequencyMaximum of one time every 30 seconds
Mains voltage - max480 V
Mains voltage - min380 V
Operating modeSpeed control with slip compensation; U/f control
Output frequency - max300 Hz
Output voltage (U2)480 V AC, 3-phase; 400 V AC, 3-phase
Overload current IL at 150% overload12.75 A
Rated control supply voltage10 V DC (Us, max. 0.2 mA)
Rated frequency - max66 Hz
Rated frequency - min45 Hz
Rated operational current (Ie)8.5 A at 150% overload (at an operating frequency of 16 kHz and an ambient air temperature of +50 °C)
Rated operational power at 380/400 V, 50 Hz
3-phase4 kW
Rated operational voltage480 V AC, 3-phase; 400 V AC, 3-phase
Resolution0.025 Hz (Frequency resolution, setpoint value)
Short-circuit protection rating15 A, UL (Class CC or J), Safety device (fuse or miniature circuit-breaker), Power Wiring
Starting current - max200 %, IH, max. starting current (High Overload), For 1.875 seconds every 600 seconds, Power section
Supply frequency50/60 Hz
Switching frequency16 kHz, 4 - 32 kHz adjustable (audible), fPWM, Power section, Main circuit
Voltage rating - max480 V
Assigned motor current IM at 400 V, 50 Hz
150% overload8.5 A
Assigned motor current IM at 440 - 480 V, 60 Hz
150% overload7.6 A
Assigned motor power at 460/480 V, 60 Hz
3-phase5 HP
Power consumption120 W
With control elementNo
Number of digital inputs4
Number of analogue inputs1
Supporting protocol for LONNo
Number of HW-interfaces RS-4851
With optical interfaceNo
Supporting protocol for TCP/IPNo
Supporting protocol for ASINo
Supporting protocol for PROFIBUSNo
Supporting protocol for CANNo
Supporting protocol for INTERBUSNo
Supporting protocol for KNXNo
Supporting protocol for ModbusYes
Supporting protocol for Data-HighwayNo
Supporting protocol for DeviceNetNo
Supporting protocol for SUCONETNo
Supporting protocol for other bus systemsYes
With PC connectionYes
Supporting protocol for SERCOSNo
Supporting protocol for INTERBUS-SafetyNo
Mains voltage380–480 V
Mains frequency50/60 Hz
4-quadrant operation possibleNo
Type of converterU converter
Number of phases output3
Number of phases input3
Integrated breaking resistanceNo
Application in industrial area permittedYes
Application in domestic- and commercial area permittedYes
Max. output frequency300 Hz
Max. output at linear load at rated output voltage0.5 kW
Max. output at quadratic load at rated output voltage0.5 kW
Relative symmetric net voltage tolerance10 %
Relative symmetric net frequency tolerance10 %
Supporting protocol for AS-Interface Safety at WorkNo
Supporting protocol for DeviceNet SafetyNo
Supporting protocol for EtherNet/IPYes
Supporting protocol for Foundation FieldbusNo
Supporting protocol for PROFINET CBANo
Supporting protocol for PROFINET IONo
Supporting protocol for PROFIsafeNo
Supporting protocol for SafetyBUS pNo
Max. output voltage500 V
Nominal output current I2N8.5 A
Supporting protocol for BACnetNo
Country of originUnited Kingdom

Properties

MOQ1

Cross-References