| Manufacturer part number (MPN) | EMR6-IM15-A-1 |
| EAN / GTIN | 4015081788170 |
| Sales unit | pcs |
| Eaton catalogue number | 184781 |
| Depth | 103.7 mm |
| Height | 85.6 mm |
| Width | 22.5 mm |
| Weight | 0.155 kg |
| Certifications | GL; EAC; CSA-C22.2 No. 14; CCC; RMRS; UL 508 |
| Catalog Notes | Extension of the measurement range possible with current transformers |
| Ambient operating temperature - max | 60 °C |
| Ambient storage temperature - max | 85 °C |
| Ambient operating temperature - min | -25 °C |
| Climatic proofing | Damp heat, cyclic, to IEC 60068-2-30 |
| Air discharge | Air/contact discharge, according to IEC/EN 61000-4-2, level 3 |
| Burst impulse | According to IEC/EN 61000-4-4, level 3 |
| Electromagnetic compatibility | According to IEC/EN 60947-6-2 |
| Immunity to line-conducted interference | Level 3 (according to IEC/EN 61000-4-6) |
| Immunity to radiation | Level 3 (according to IEC/EN 61000-4-3) |
| Surge rating | According to IEC/EN 61000-4-5 Level 4 |
| Current measurement - max | 15 A |
| Current measurement - min | 0.3 A |
| Electric connection type | Screw connection |
| Functions | DC-voltage over current; Single-phase under current possible; Monitoring of single-phase DC and AC networks; Single-phase over current possible; DC-voltage under current |
| Monitoring function | Overcurrent; Undercurrent |
| Voltage measurement - max | 240 V |
| Voltage measurement - min | 24 V |
| Degree of protection | Terminals: IP20; Enclosure: IP50 |
| LED indicator | Status indication of energized output relay: Yellow LED; Status indication of Supply voltage: Green, solid light; Status indication of measured value: Red LED; Other states depending on fault (see IL): Measured value; Status indication of Supply voltage: Green LED |
| Lifespan, mechanical | 30,000,000 Operations |
| Mounting position | As required |
| Overvoltage category | III |
| Pollution degree | 3 |
| Product category | EMR Measuring and monitoring relays |
| Rated impulse withstand voltage (Uimp) | 4000 V AC |
| Shock resistance | Class 2 |
| Type | Current monitoring relay |
| Voltage type | AC/DC |
| Hysteresis | 3 - 30 % |
| Input current | Input B1-C: 0.3 - 1.5 A; Input B2-C: 1 - 5 A; Input B3-C: 3 - 15 A |
| Measuring cycle | 80 ms |
| Temperature error | 0.06 %/°C, Measuring circuits |
| Duty factor | 100 %, Power supply |
| Power consumption | 2.6 VA |
| Rated control supply voltage (Us) at AC |
| 50 Hz - max | 240 V |
| Rated control supply voltage (Us) at AC |
| 50 Hz - min | 24 V |
| Rated control supply voltage (Us) at AC |
| 60 Hz - max | 240 V |
| Rated control supply voltage (Us) at AC |
| 60 Hz - min | 24 V |
| Rated control supply voltage (Us) at DC - max | 240 V |
| Rated control supply voltage (Us) at DC - min | 24 V |
| Rated frequency - max | 60 Hz |
| Rated frequency - min | 50 Hz |
| Supply voltage | 24 - 240 V DC; 24 - 240 V AC, 50/60 Hz |
| Voltage tolerance | 0.85 x Uc; 1.1 x Uc |
| Lifespan, electrical | 100,000 Operation (at 230 V, AC-12, 4 A) |
| Number of contacts (change-over contacts) | 2 |
| Number of contacts (normally closed contacts) | 0 |
| Number of contacts (normally open contacts) | 0 |
| Rated operational current (Ie) | 4 A at AC-12, 230 V; 4 A at DC-12, 24 V |
| Rated operational current (Ie) at AC-15, 220 V, 230 V |
| 240 V | 3 A |
| Rated operational current (Ie) at DC-13 |
| 24 V | 2 A |
| Rated operational voltage (Ue) at AC - max | 250 V |
| Short-circuit protection rating | Max. 10 A Fast/gL, Fuse, Relay output contacts |
| Connection type | Snap fixing, top-hat rail IEC/EN 60715 |
| Screwdriver size | 4 x 0.8 mm, Terminal screw |
| Terminal capacity (flexible with ferrule AWG) | 2 x 18-16 |
| Terminal capacity (flexible with ferrule) | 2 x 0.5-1.5 mm² |
| Terminal capacity (solid AWG) | 18 - 14 |
| Terminal capacity (solid) | 1 x 0.5-2.5 mm² |
| Tightening torque | 0.8 Nm, Screw terminals; Min. 0.6 Nm, Screw terminals |
| Delay time | Adjustable from 0.1 - 30 s |
| Response delay time; Switch-on delay | none = 0 or adjustable from 0.1 to 30 s |
| On-delay | 0.1 - 30 ms |
| Timing cycle | 0.5 %, Time error within supply voltage; 0.06 %/°C, Time error within temperature range; 30 s, Reset delay/Off-delay time; 0.5 % Error within supply voltage (Measuring circuits) |
| Operating voltage AC 50 Hz | 24–240 V |
| Operating voltage AC 60 Hz | 24–240 V |
| Operating voltage DC | 24–240 V |
| External power supply required | No |
| Supply voltage AC 50 Hz | 24–240 V |
| Supply voltage AC 60 Hz | 24–240 V |
| Supply voltage DC | 24–240 V |
| Rated switch current | 4 A |
| Response value amperage 1 | 3–15 A |
| Response value amperage 2 | 0.3–1.5 A |
| Voltage measuring range | 24–240 V |
| Type of current | AC/DC |
| Type of electric connection | Screw connection |
| With detachable clamps | No |
| Single-phase under current possible | Yes |
| Three-phase under current possible | No |
| Single-phase overcurrent possible | Yes |
| Three-phase overcurrent possible | No |
| Single-phase hysteresis possible | No |
| Three-phase hysteresis possible | No |
| Contains function DC-voltage under current | Yes |
| Contains function DC-voltage overcurrent | Yes |
| Function DC-current hysteresis | No |
| Rated control supply voltage AC 50 Hz | 24–240 V |
| Rated control supply voltage AC 60 Hz | 24–240 V |
| Rated control supply voltage DC | 24–240 V |
| Voltage type for actuating | AC/DC |
| Current measuring range | 0.3–15 A |
| Min. adjustable delay-on energization time | 0.1 s |
| Max. permitted delay-on energization time | 30 s |
| Number of contacts as change-over contact | 2 |
| External current transformer | No |
| Country of origin | Germany |
| Min. adjustable off-delay time | 0 s |