cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Contactor,DILH600-SIZE S/22(110-120V50/60HZ) (197908)

Eaton · Electrical Components · Contactors · Ireland · eaton.com
Part Number
197908  ·  HS 8536.90
Contactor,DILH600-SIZE S/22(110-120V50/60HZ) (197908)

Eaton 197908 Contactor, Ith =Ie: 850 A, 110 - 120 V 50/60 Hz, AC drift, Screw Terminal.

Technical Specifications

Manufacturer part number (MPN)197908
EAN / GTIN4015081954278
HS code8536.90
Sales unitpcs
Eaton catalogue number197908
Depth216 mm
Height237 mm
Width160 mm
Weight8.85 kg
Conventional thermal current Ith (3-pole, enclosed)600 A
Conventional thermal current Ith at 40°C (3-pole, open)850 A
Conventional thermal current Ith at 50°C (3-pole, open)760 A
Conventional thermal current Ith at 55°C (3-pole, open)725 A
Conventional thermal current Ith at 60°C (3-pole, open)695 A
Conventional thermal current Ith of main contacts (1-pole, open)1738 A
AltitudeMax. 2000 m
Ambient operating temperature - max70 °C
Ambient storage temperature - max80 °C
Ambient operating temperature - min-40 °C
Ambient storage temperature - min-40 °C
Climatic proofingDamp heat, cyclic, to IEC 60068-2-30; Damp heat, constant, to IEC 60068-2-78
Number of auxiliary contacts (normally closed contacts)2
Number of auxiliary contacts (normally open contacts)2
Equipment heat dissipation, current-dependent Pvid0 W
Heat dissipation capacity Pdiss0 W
Rated operational current for specified heat dissipation (In)650 A
Static heat dissipation, non-current-dependent Pvs3.3 W
Rated breaking capacity at 1000 V1575 A
Rated breaking capacity at 220/230 V4800 A
Rated breaking capacity at 380/400 V4800 A
Rated breaking capacity at 500 V4800 A
Rated breaking capacity at 660/690 V2000 A
Rated insulation voltage (Ui)1000 V
Rated making capacity up to 440 V (cos phi to IEC/EN 60947)6000 A
Rated operational voltage (Ue) at AC - max1000 V
Safe isolation1000 V AC, Between coil and contacts, According to EN 61140
AccessoriesFitting options auxiliary contacts: on the side: 2 x DILM820-XHI11(V)-SI; 2 x DILM820-XHI11-SA
ApplicationMains contactors for resistive loads from 1000 A
ConnectionScrew terminals
Degree of protectionIP00
Electromagnetic compatibilityDesigned for operation in industrial environments. Its use in residential environments may cause radio-frequency interference, requiring additional noise suppression.
Fitted withSuppressor circuit in actuating electronics
Lifespan, mechanical3,000,000 Operations (AC operated); 3,000,000 Operations (DC operated)
Operating frequency1000 mechanical Operations/h (AC operated); 1000 mechanical Operations/h (DC operated)
Overvoltage categoryIII
Pollution degree3
Product categoryContactors
Rated impulse withstand voltage (Uimp)12000 V
Resistance500 mΩ (Admissible transitional contact resistance - of the external control circuit device when actuating A11)
Shock resistance8 g, N/C auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O main contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms; 10 g, N/O auxiliary contact, Mechanical, according to IEC/EN 60068-2-27, Half-sinusoidal shock 10 ms
Signal level5 V - 15 V, PLC signal level (A3 - A4) to IEC/EN 61131-2 (type 2), Magnet systems
Utilization categoryAC-1: Non-inductive or slightly inductive loads, resistance furnaces
Voltage typeAC
Duty factor100 %
Pick-up voltage0.85 - 1.1 V AC x Us
Power consumptionControl transformer with uk ≤ 7%
Power consumption, pick-up, 50 Hz645 W, Pull-in power, Coil in a cold state and 1.0 x Us; 715 VA, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, pick-up, 60 Hz715 VA, Pull-in power, Coil in a cold state and 1.0 x Us; 645 W, Pull-in power, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 50 Hz3.3 W, Coil in a cold state and 1.0 x Us
Power consumption, sealing, 60 Hz3.3 W, Coil in a cold state and 1.0 x Us
Rated control supply voltage (Us) at AC, 50 Hz - max120 V
Rated control supply voltage (Us) at AC, 50 Hz - min110 V
Rated control supply voltage (Us) at AC, 60 Hz - max120 V
Rated control supply voltage (Us) at AC, 60 Hz - min110 V
Switching time (AC operated, make contacts, closing delay) - max60 ms
Switching time (AC operated, make contacts, opening delay) - max50 ms
Switching capacity (auxiliary contacts, general use)10 A, 600 V AC, (UL/CSA); 1 A, 250 V DC, (UL/CSA)
Switching capacity (auxiliary contacts, pilot duty)A600, AC operated (UL/CSA); P300, DC operated (UL/CSA)
Switching capacity (main contacts, general use)700 A, Maximum motor rating (UL/CSA)
Screw sizeM3.5, Terminal screw; M10, Terminal screw
Screwdriver size0.8 x 5.5/1 x 6 mm, Terminal screw, Control circuit cables, Standard screwdriver; 2, Terminal screw, Pozidriv screwdriver
Stripping length (control circuit cable)10 mm
Terminal capacity (busbar)50 mm width, Main connection
Terminal capacity (flexible with cable lug)50 - 240 mm²
Terminal capacity (flexible with ferrule)1 x (0.75 - 2.5) mm²; 2 x (0.75 - 2.5) mm²
Terminal capacity (solid)2 x (0.75 - 2.5) mm²; 1 x (0.75 - 2.5) mm²
Terminal capacity (solid/stranded AWG)18 - 14
Terminal capacity (stranded with cable lug)70 - 240 mm²
Tightening torque24 Nm, Main cable connection screw/bolt; 1.2 Nm, Screw terminals
Width across flats16 mm

Properties

MOQ1

Cross-References

Attached Documents