Enclosures H×W×D=375X375X225MM (KST44-200)

Eaton · Enclosures · Industrial Enclosures · Ireland · eaton.com
Part Number
KST44-200  ·  HS 8547.20
Enclosures H×W×D=375X375X225MM (KST44-200)

Technical Specifications

Manufacturer part number (MPN)KST44-200
EAN / GTIN4015080935049
Sales unitpcs
Eaton catalogue number093504
Depth225 mm
Height375 mm
Width375 mm
Weight3.4 kg
CompliancesIEC/EN 60439-1, VDE 0660 Part 500; RoHS conform
CertificationsEN 61439-2; EN 62208
FeaturesUV resistance beneath protective shield; Cover with overpressure release
Flammability characteristics (UL)V2 (cover) (UL94); V1 (base) (UL94)
Flammability characteristics of glow rod testVDE 0304 Part 3 level IIb, level IIb to IEC 60707
FunctionsExtension possible
Protection classII
RAL-number7035
Special featuresLow-voltage fuses (IEC/EN 60269, VDE 0636) Sealable cover fasteners Sides closed, but with full area knockout Open top Fitting of cable supports in the distribution board with wedge-lock fastener Gland plate can be split, cables can be inserted from the front
Suitable forLightning protection; Outdoor use
Surface resistance (IEC 60093)10 TΩ
Used withThe reference values indicated in the table apply to the basic elements of the distribution board. As far as devices, terminals etc. fitted into the enclosures are concerned, their own specific technical data and rated values apply.
ColorGray; Light gray (RAL 7035, base); Transparent, smoky gray (cover)
Nominal current1600 A
TypeBasic enclosure Panel enclosure with gland plates fitted xEnergy Safety Ci
Ambient operating temperature - max40 °C
Ambient operating temperature - min-5 °C
Mean ambient operating temperature (24 hours)35 °C
Temperature resistanceTemperature resistant: -40 °C - 120 °C (enclosure); Temperature resistant: 85 °C (enclosure bolt); Temperature resistant: 80 °C (gasket)
Circuit integrityOther
Creepage resistanceKB160, KC175 (base, to IEC 60112); KB100, KC200 (cover, to IEC 60112)
Dielectric strength30 kV/mm
Operating altitude without derating - max2000 mm
Cable entry type14 - 68 mm (3x)
Chemical resistancePartly resistant to: Acids > 10 %; Not resistant to: alkalis, benzene; Resistant against: acids < 10 %, mineral oil, alcohol, gasoline, greases, salt solutions
Cover/door colorTransparent
Cover/door modelClosed
Cover/door typeCover; None
Creepage and clearance distancesIII/3 to IEC/EN 60439-1 (standard)
Degree of protectionIP65 (enclosure); IP64 (KST cable entries from above); IP00 (cable entry open); IP65 (KST cable entries from below); IP65; IK10; Other
Enclosure materialPlastic
MaterialHalogen free; Glass-fibre reinforced polycarbonate (base); Non-reinforced polycarbonate (cover)
Mounting depth with mounting plate200 mm
Mounting grid25 mm (DIN 43660)
Number of conduit inlets100
Number of modules1
Number of openings (flange plates)4
Number of rows0
Plate thickness (cabinet)6 mm
Plate thickness (cover/door)6 mm
Relative humidity50 % (at 40 °C); 90 % (at 20 °C)
Saline spray resistanceIEC 60068-2-11
Surface protectionOther
Unit typeStand-alone device
Width in number of modular spacings15
Built-in depth200 mm
Internal depth200 mm
Mounting methodSurface mounted (plaster)
Dimensions375×375×225 mm
ColourGrey
With mounting plateNo
Impact strengthIK10
Country of originPoland

Properties

MOQ1

Cross-References