cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Residual current circuit breaker 16/4/003-A (170285)

Eaton · Electrical Components · RCDs & RCBOs · Ireland · eaton.com
Part Number
170285  ·  HS 8536.90
Residual current circuit breaker 16/4/003-A (170285)

Eaton 170285 FRCMM-16/4/003-A.

Technical Specifications

Manufacturer part number (MPN)170285
EAN / GTIN4015081667840
HS code8536.90
Sales unitpcs
Package quantity30 pcs
Eaton catalogue number170285
Depth76 mm
Height80 mm
Width70 mm
Weight0.352 kg
CompliancesRoHS conform
CertificationsIEC/EN 61008; EN45545-2; IEC 61373
FeaturesAdditional equipment possible; Residual current circuit breaker
Fitted withInterlocking device
Special featuresCurrent test marks as per inscription Maximum operating temperature is 55 °C: Starting at 40 °C, the max. permissible continuous current decreases by 3% for every 1 °C
Used withResidual current circuit breakers; FRCmM; Type A
Amperage Rating16 A
ApplicationSwitchgear for industrial and advanced commercial applications xEffect - Switchgear for industrial and advanced commercial applications
Fault current rating30 mA
Impulse withstand currentPartly surge-proof 250 A; 250 A (8/20 μs) surge-proof
Number of polesFour-pole
Rated short-circuit strength10 kA with back-up fuse
Sensitivity typePulse-current sensitive
Tripping timeNon-delayed
TypeFRCmM Residual current circuit breakers Type A
Ambient operating temperature - max40 °C
Ambient operating temperature - min-25 °C
Equipment heat dissipation, current-dependent2.9 W
Heat dissipation per pole, current-dependent0.725 W
Rated operational current for specified heat dissipation (In)16 A
Admissible back-up fuse overload - max16 A gG/gL
Frequency rating50 Hz / 60 Hz
Leakage current typeA
Lifespan, electrical4000 operations
Pollution degree2
Rated fault current - max0.03 A
Rated fault current - min0.03 A
Rated impulse withstand voltage (Uimp)4 kV
Rated insulation voltage (Ui)440 V
Rated operational voltage (Ue) - max415 V
Rated residual making and breaking capacity500 A
Rated short-time withstand current (Icw)10 kA
Short-circuit rating63 A (max. admissible back-up fuse)
Surge current capacity0.25 kA
Test circuit range184 V AC - 440 V AC
Voltage rating (IEC/EN 60947-2)240 V AC / 415 V AC
Built-in depth70.5 mm
Built-in width (number of units)70 mm (2 SU)
Busbar material thickness0.8 mm - 2 mm
Climatic proofing25-55 °C / 90-95% relative humidity according to IEC 60068-2
Connectable conductor cross section (multi-wired) - max16 mm²
Connectable conductor cross section (multi-wired) - min1.5 mm²
Connectable conductor cross section (solid-core) - max35 mm²
Connectable conductor cross section (solid-core) - min1.5 mm²
Contact position indicator colorRed / green
Degree of protectionIP20; IP20, IP40 with suitable enclosure
Frame45 mm
Lifespan, mechanical20000 operations
Mounting MethodDIN rail; Quick attachment with 2 latch positions for DIN-rail IEC/EN 60715
Mounting positionAs required
Permitted storage and transport temperature - max60 °C
Permitted storage and transport temperature - min-35 °C
Status indicationWhite / blue
Terminal capacity (cable)M5 (with cross-recessed screw as defined in EN ISO 4757-Z2, PZ2)
Terminal capacity (solid wire)1.5 mm² - 35 mm²
Terminal capacity (stranded cable)16 mm² (2x)
Terminal protectionFinger and hand touch safe, DGUV VS3, EN 50274
Terminals (top and bottom)Twin-purpose terminals
Tightening torque2 Nm - 2.4 Nm
Width in number of modular spacings4
Document NameDescription Action

Properties

MOQ1

Cross-References

Attached Documents