cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton 183035 FUSE-Switch (XNH00-S160-BT2)

Eaton · Switchgear & Protection · Fuse Switch-Disconnectors · Ireland · eaton.com
Part Number
XNH00-S160-BT2  ·  HS 8536.90
Eaton 183035 FUSE-Switch (XNH00-S160-BT2)

Eaton XNH00-S160-BT2 NH fuse-switch 3p with lowered box terminal BT2 1,5 - 95 mm², busbar 60 mm, NH000 & NH00.

Technical Specifications

Manufacturer part number (MPN)XNH00-S160-BT2
EAN / GTIN4015081779628
HS code8536.90
Sales unitpcs
Eaton catalogue number183035
Depth204 mm
Height137 mm
Width106 mm
Weight0.863 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947-3
FeaturesHalogen free; Standard sealable
Flammability characteristics (UL)Self-extinguishing (UL 94)
Special featuresPermanent operation (rated operating mode) Current paths of electrolytic copper, silver-plated Cable connection optionally at the top or bottom
Suitable forBusbar mounting; Front mounting
Actuator typeCover grip
ColorGray
Number of polesThree-pole
TypeBasic device
Ambient operating temperature detailsAmbient temperature range: -25 °C - 70 °C
Equipment heat dissipation, current-dependent14 W
Heat deflection temperature125 °C
Heat dissipation at 80% without fuses9 W
Heat dissipation per pole, current-dependent4.7 W
Rated operational current for specified heat dissipation (In)160 A
Total heat dissipation without fuses at Ith14 W
Creepage resistanceCTI 600
Direction of incoming supplyAs required (FLEX System)
Electrical connection type of main circuitFrame clamp
Frequency rating40 Hz - 60 Hz
Frequency rating of contacts40 Hz - 60 Hz
Lifespan, electrical300 operations
Operating altitude without derating - max2000 mm
Overvoltage categoryIII
Permitted power loss per fuse link - max12 W
Pollution degree3
Power rating at AC-23, 400 V0 kW
Rated conditional short-circuit rating100 kA (690 V); 120 kA (500 V)
Rated impulse withstand voltage (Uimp)8 kV
Rated insulation voltage (Ui)800 VAC
Rated operating voltage (Ue) at AC - max690 V
Rated operation current (Ie)160 A
Rated operational current160 A (AC-23B); 160 A (AC-21B); 160 A (AC-22B); 160 A
Rated short-time withstand current (Icw)7 kA
Rated uninterrupted current (Iu)160 A
Voltage rating at AC400 V (AC-23B) 500 V (AC-22B) 690 V (AC-21B)
Voltage rating at DC250 V DC at DC-22B 440 V DC at DC-21B
Voltage testYes, sliding inspection windows
Conditioned rated short-circuit current Iq120 kA
Rated conditional short-circuit current (Iq)120 kA
Activation typeDependent manual activation
Actuator positionFront side
Cable entry typeOther
Degree of protection (front side)Other
Lifespan, mechanical1400 operations
Locking facilityYes, optional
MaterialPolyamide
Mounting methodBusbars of 60 mm
Mounting positionVertical or horizontal
SizeNH000 / NH00 fuse
Suitable for fusesNH00
Terminal capacity (copper band)9 mm x 0.8 mm (6x) at box terminal
Terminal capacity (copper busbar)Max. 25 mm cable lug width at flange connection; 20 mm x 10 mm; Bolt diameter at flange connection: M8
Terminal capacity (copper strip)9 mm x 0.8 mm (9x) at box terminal
Terminal capacity (stranded cable)1.5 mm² - 95 mm² at box terminal; 10 mm² - 70 mm² at clamp-type terminal; 1.5 mm² - 50 mm² at box terminal
Connection typeBox terminal
Degree of protectionIP2XC (contact protection, XNH installed); IP10 (handle cover open, XNH installed); IP20 (operating status, XNH installed)

Properties

MOQ1

Cross-References

Attached Documents