cBallast
Industrial Parts Catalog
Datasheet generated 2026-10-07
sales@cballast.com
cballast.com

Eaton 183031 FUSE-Switch (XNH00-1-A160)

Eaton · Switchgear & Protection · Fuse Switch-Disconnectors · Ireland · eaton.com
Part Number
XNH00-1-A160  ·  HS 8536.90
Eaton 183031 FUSE-Switch (XNH00-1-A160)

Eaton XNH00-1-A160 NH fuse-switch 1p flange connection M8 max. 95 mm², mounting plate, NH000 & NH00.

Technical Specifications

Manufacturer part number (MPN)XNH00-1-A160
EAN / GTIN4015081779581
HS code8536.90
Sales unitpcs
Eaton catalogue number183031
Depth204 mm
Height84 mm
Width49 mm
Weight0.289 kg
CompliancesRoHS conform
CertificationsIEC/EN 60947-3
FeaturesHalogen free; Standard sealable
Flammability characteristics (UL)Self-extinguishing (UL 94)
Special featuresCurrent paths of electrolytic copper, silver-plated Permanent operation (rated operating mode)
Suitable forGround mounting; Front mounting
Actuator typeCover grip
ColorGray
Number of polesSingle-pole
TypeBasic device
Ambient operating temperature detailsAmbient temperature range: -25 °C - 70 °C
Equipment heat dissipation, current-dependent9 W
Heat deflection temperature125 °C
Heat dissipation at 80% without fuses5.8 W
Heat dissipation per pole, current-dependent3 W
Rated operational current for specified heat dissipation (In)160 A
Total heat dissipation without fuses at Ith9 W
Creepage resistanceCTI 600
Direction of incoming supplyAs required
Electrical connection type of main circuitScrew connection
Frequency rating40 Hz - 60 Hz
Frequency rating of contacts40 Hz - 60 Hz
Lifespan, electrical300 operations
Operating altitude without derating - max2000 mm
Overvoltage categoryIII
Permitted power loss per fuse link - max12 W
Pollution degree3
Power rating at AC-23, 400 V0 kW
Rated conditional short-circuit rating100 kA (690 V); 120 kA (500 V)
Rated impulse withstand voltage (Uimp)8 kV
Rated insulation voltage (Ui)800 VAC
Rated operating voltage (Ue) at AC - max690 V
Rated operation current (Ie)160 A
Rated operational current160 A; 160 A (AC-21B); 160 A (AC-22B); 160 A (AC-23B)
Rated short-time withstand current (Icw)7 kA
Rated uninterrupted current (Iu)160 A
Voltage rating at AC400 V (AC-23B) 500 V (AC-22B) 690 V (AC-21B)
Voltage rating at DC250 V DC at DC-22B 440 V DC at DC-21B
Voltage testYes, sliding inspection windows
Conditioned rated short-circuit current Iq120 kA
Rated conditional short-circuit current (Iq)120 kA
Activation typeDependent manual activation
Actuator positionFront side
Cable entry typeOther
Degree of protection (front side)Other
Lifespan, mechanical1400 operations
Locking facilityYes, optional
MaterialPolyamide
Mounting methodMounting plate; DIN rail
Mounting positionVertical or horizontal
SizeNH000 / NH00 fuse
Suitable for fusesNH00
Terminal capacity (copper band)9 mm x 0.8 mm (6x) at box terminal
Terminal capacity (copper busbar)Max. 25 mm cable lug width at flange connection; Bolt diameter at flange connection: M8; 20 mm x 10 mm
Terminal capacity (copper strip)9 mm x 0.8 mm (9x) at box terminal
Terminal capacity (stranded cable)1.5 mm² - 50 mm² at box terminal; 1.5 mm² - 95 mm² at box terminal; 10 mm² - 70 mm² at clamp-type terminal
Connection typeFlat connection
Degree of protectionIP10 (handle cover open, XNH installed); IP2XC (contact protection, XNH installed); IP20 (operating status, XNH installed)

Properties

MOQ1

Cross-References

Attached Documents